INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Clearances and Dimensions

1. Provide adequate clearances between the range and adjacent combustible surfaces.
2. Location—Check location where the range will be installed. Check for proper electrical supply, and the stability of the floor.
3. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid
and level.
Fig. 1
*30" MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE BOTTOM OF AN UNPROTECTED WOOD OR METAL
CABINET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT LESS THAN 1/4" FLAME RETARDANT
MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015" STAINLESS STEEL, 0.024" ALUMINUM OR 0.020" COPPER.
0" CLEARANCE IS THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO
PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE LOCATED
ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY
INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" BEYOND THE BOTTOM OF THE CABINETS.
IMPORTANT SAFETY INSTRUCTIONS
If the information in this manual is not followed
exactly, a fire or electrical shock may result causing property
damage, personal injury or death.
Important Notes to the Installer
Read all instructions contained in these installation instructions
before installing range.
Remove all packing material from the oven compartments
before connecting the gas & electrical supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.
Español - Páginas 5-8
Fig. 2
Fig. 3
Important Note to the Consumer
Keep these instructions with your owner's guide for future reference.
As when using any appliance generating heat, there are
certain safety precautions you should follow. These are listed
in the Use & Care Guide, read it carefully.
Be sure your range is installed and grounded properly by a
qualified installer or service technician.
Make sure the wall coverings around the range can withstand
the heat generated by the range.
To eliminate the need to reach over the surface elements,
cabinet storage space above the elements should be avoided.
Serial Plate Locations:
Serial plate is located on the lower right front frame of the appliance.
Alternate location may be under cooktop.
1
30"
p/n 316454912 rev A

Advertisement

loading

Summary of Contents for KitchenAid KERS206XSS

  • Page 1: Clearances And Dimensions

    INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Clearances and Dimensions 1. Provide adequate clearances between the range and adjacent combustible surfaces. 2.
  • Page 2 INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE BEFORE STARTING 3/16" pilot hole 1-3/4" deep. The screws provided may be used Tools You Will Need in wood or concrete material. Use a 5/16" nut-driver or flat head screwdriver to secure the bracket in place (See Fig. 6). For leveling legs and Anti-Tip Bracket: 1c.
  • Page 3 INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE 2b. MODELS REQUIRING POWER SUPPLY CORD KIT. RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF AN INCORRECT SIZE RANGE CORD KIT IS USED, THE INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED OR STRAIN RELIEF BRACKET IS DISCARDED. This appliance may be connected by means of a power supply cord.
  • Page 4 INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE or 4B. POWER CORD CONNECTIONS (3-Wire Connection Instructions . For existing installations ONLY - Refer to Fig. 13). Follow the manufacturer’s installation instructions supplied with the strain relief and install (Also see Figs. 9, 10 & 11). Insert the end connectors for Line 1, Line 2 and Neutral and tighten securely to the terminal block (See Fig.

This manual is also suitable for:

Kers208xssKers308xss