About this document
This document describes the procedure for replacing the Operator
Control Panel (OCP).
CAUTION:
This procedure assumes the storage system is running XCS 6.000
or later. If you are running an earlier version of XCS, contact your
HP-authorized service representative for assistance in replacing
the OCP.
Warranty information
If the product in which this part is being replaced is still under
HP warranty, then the replacement part(s) referred to in these
Replacement Instructions is provided under the terms and conditions
of the Hewlett-Packard Company Limited Warranty for that
product. A copy of this Limited Warranty may be viewed at:
http://h18006.www1.hp.com/products/storageworks/warranty.html
If this is a trade sale part (product out of warranty), then the replacement
part(s) referred to in these Replacement Instructions is provided under
HP's express limited warranty statement, which may be viewed at:
http://customerops.corp.hp.com/1sw/pdm_om/warranty_support/
policies/2330100.doc
The replacement part takes on either the Limited Warranty Period of the
part being replaced or a ninety-day period that begins upon installation
of the replacement part, whichever is greater.
The only warranty for this replacement product is as noted above.
Nothing in these replacement instructions should be construed as
constituting an additional warranty. The information provided in these
replacement instructions is provided "AS IS" and HP is not liable for
technical or editorial errors or omissions contained herein.
Before you begin
Observe the following precautions when replacing the OCP:
•
Removing the OCP significantly changes the air flow within the
enclosure. The OCP must be installed for the enclosure to cool
properly. If the OCP fails, leave it in place in the enclosure until a
new OCP is available to install.
•
Parts can be damaged by electrostatic discharge. Use proper
anti-static protection.
•
Use care when replacing the OCP to avoid damaging the enclosure.
Removing the OCP
1.
Remove the front panel (1,
end pulling it off the enclosure.
2.
Press the OCP latch (2) and swing the panel out until it is fully open.
CAUTION:
Handle the OCP by its metal frame only. This will ensure that the
electronic components are not damaged by static discharge.
3.
Grasp the OCP by its metal frame and pull it out of the enclosure
(3).
Page 1
Figure
1) by grasping the panel at each