Table C-1
Numeric Codes and Text Messages (continued)
Control panel message
2202-PMM Deallocation Error during MEBx
cleanup
2203-Setup error during MEBx execution
2204-Inventory error during MEBx execution BIOS information passed to the MEBx
2205-Interface error during MEBx execution
2211-Memory not configured correctly for
proper MEBx execution.
Invalid Electronic Serial Number
Network Server Mode Active and No
Keyboard Attached
Description
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM
MEBx selection or exit resulted in a setup
failure.
resulted in a failure.
MEBx operation experienced a hardware
error during communication with ME.
DIMM1 is not installed.
Electronic serial number is missing.
Keyboard failure while Network Server Mode
enabled.
Recommended action
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
Make sure there is a memory module in the
black DIMM1 socket and that it is properly
seated.
Enter the correct serial number in Computer
Setup.
1.
Reconnect keyboard with computer
turned off.
2.
Check connector for bent or missing
pins.
3.
Ensure that none of the keys are
depressed.
4.
Replace keyboard.
POST Numeric Codes and Text Messages 137