COMPONENT TESTING INFORMATION
5
When checking the Component, be sure to turn the power off, and do voltage discharge sufficiently.
CAUTION
!
Component
1. Thermal cut off
• Check Top Marking :
N130
2. Hi limit Thermostat
(Auto reset)
3. Outlet Thermostat
( Auto reset)
• Check Top Marking :
N85
4. Lamp holder
5. Door switch
6. Idler switch
Test Procedure
Measure resistance of terminal
to terminal
Open at 266 ± 12°F
(130 ± 7°C)
Auto reset -31°F (-35°C)
Same shape as Outlet Thermostat.
Measure resistance of terminal
to terminal
Open at 257 ± 9°F
(125 ± 5°C)
Close at 221 ± 9°F
(105 ± 5°C)
Measure resistance of terminal
to terminal
Open at 185 ± 9°F
(85 ± 5°C)
Close at 149 ± 9°F
(65 ± 5°C)
Same shape as Thermal cut off.
Measure resistance of terminal
to terminal
Measure resistance of the
following terminal
1) Door switch knob : open
Terminal : "COM" - "NC" (1-3)
Terminal : "COM" - "NO" (1-2)
2) Door switch push : push
Terminal : "COM" - "NC" (1-3)
Terminal : "COM" - "NO" (1-2)
Measure resistance of the
following terminal :
"COM - NC"
Check result
If thermal fuse is open must
be replaced
Resistance value
Continuity (250°F
Resistance value
Resistance value < 5Ω
Resistance value
Resistance value < 5Ω
Resistance value :
80Ω ~ 100Ω
Resistance value < 1Ω
Resistance value
Resistance value
Resistance value < 1Ω
1. lever open
Resistance value < 1Ω
2. Lever push (close)
Resistance value
14
Remark
• Heater case-
Safety
∞
• Electric type
) < 1Ω
• Heater case -
Hi limit
∞
• Electric type
• Blow housing -
Safety
∞
• Electric type
The state that
Knob is
pressed is
opposite to
Open
∞
condition.
∞
∞