Quick Links

BASIC SERIAL COMMAND SPECIFICATIONS
PLC-XK2200
PLC-XK2600
PLC-XK3010
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-XK2200 - 2200 Lumens

  • Page 1 BASIC SERIAL COMMAND SPECIFICATIONS PLC-XK2200 PLC-XK2600 PLC-XK3010 Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications ÿ CONTENTS ÿ Overview .........................3 Serial Interface Specifications..................3 2.1. Transfer Specifications ..................3 2.2. Connection ......................3 Notes for Communication .....................4 Functional Execution Command Table................5 Status Read Command Table..................7 Functional Execution Command ..................8 6.1.
  • Page 3 PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.32. BRIGHTNESS – Command...................14 6.33. IMAGE (Toggle) Command...................14 6.34. Direct on Setting Command ................15 6.35. Direct on Cancel Command.................15 6.36. Power Management Ready Command ...............15 6.37. Power Management OFF Command ..............15 6.38.
  • Page 4: Overview

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 1. Overview 1.1. These specifications define projector control commands for PLC-XK2200/2600/ XK3010. 1.2. The projector control commands are used to remotely control a projector through RS-232C from a computer. 2. Serial Interface Specifications 2.1.
  • Page 5: Notes For Communication

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications Notes for Communication The projector control command is defined as one command/one line that starts with “C” and ends with carriage return (0x0D). There are two types of Commands: Functional Execution Commands and Status Read Commands.
  • Page 6: Functional Execution Command Table

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications Functional Execution Command Table Command Item Command Item POWER ON BRIGHTNESS + POWER OFF BRIGHTNESS - (Quick Power OFF) ――― POWER OFF ――― ――― ――― ――― ――― Computer 1 ――― Computer 2 Video IMAGE (Toggle) ―――...
  • Page 7 PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications Command Item Command Item ――― ――― ――― ――― ――― ――― ――― FREEZE ON ――― FREEZE OFF ――― ――― ――― ――― ――― ――― ――― ――― ――― Auto PC ADJ. ――― PRESENTATION TIMER ―――...
  • Page 8: Status Read Command Table

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications Status Read Command Table Command Item Memo Status Read Input Mode Read ――― (Corresponding) Lamp Time Read Setting Read ――― Temp Read Lamp Mode Read ――― means no function. 7/23...
  • Page 9: Functional Execution Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications Functional Execution Command 6.1. Format 6.1.1 PC issues a command in format as below. “C” COMMAND [CR] Command: two characters (See Basic Functional Execution Command Table) A projector changes received data to decode and returns a result after being ready to receive next command.
  • Page 10: Operation Requirements

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.4. Operation Requirements 1) When the projector’s status is any of below, Functional Execution Commands are limited. Projector Status Available Functional Execution Commands In Standby C00ÿ POWER ON C00ÿ POWER ON → Countdown is terminated Countdown in process C01ÿ...
  • Page 11: Power On Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.5. POWER ON Command Command “C00” [CR] Power ON When already Power is ON, nothing is done. Detail When sending this command during processing Countdown, Countdown is terminated. Acceptable [ACK] [CR] Response Unacceptable “ÿ...
  • Page 12: Video Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.10. Video Command Command “C07” [CR] Select Video Input Detail Although projector returns “OK”, Input search is not executed with this command while Input search is set to On1 or On2, Acceptable [ACK] [CR] Response...
  • Page 13: Video Mute On Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.15. VIDEO MUTE ON Command Command “C0D”[CR] Video Mute ON. Detail This command works the same way as “NO SHOW” button of the remote control for No Show ON, but does not work for No Show OFF. Acceptable [ACK] [CR] Response...
  • Page 14: Image Cinema Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.21. Image Cinema Command Command “C13” [CR] Detail Set image to Cinema mode. Acceptable [ACK] [CR] Response Unacceptable “ÿ ”[CR] 6.22. Image1 Command Command “C14” [CR] Detail Set image to Image1 mode. Acceptable [ACK] [CR] Response...
  • Page 15: Menu On Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.28. MENU ON Command Command “C1C” [CR] Detail Display On-Screen Display Menu. Acceptable [ACK] [CR] Response Unacceptable “ÿ ”[CR] 6.29. MENU OFF Command Command “C1D” [CR] Detail Hide On-Screen Display Menu. Acceptable [ACK] [CR] Response...
  • Page 16: Direct On Setting Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.34. Direct on Setting Command Command “C28” [CR] Enable Direct on function. Detail This status is stored in EEPROM and retained regardless of Power OFF/ON. Acceptable [ACK] [CR] Response Unacceptable “ÿ ”[CR] 6.35.
  • Page 17: D.zoom - Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.40. D.ZOOM – Command Command “C31” [CR] Enter Digital Zoom mode and reduce image size. Detail This command works the same as “D.ZOOM ▼” button of the remote control. Acceptable [ACK] [CR] Response Unacceptable “ÿ...
  • Page 18: Pointer Down Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.46. POINTER DOWN Command Command “C3D” [CR] Move down the Pointer of On-Screen Display Menu. Detail This command works the same way as the pointer “▼” of the projector. Acceptable [ACK] [CR] Response Unacceptable “ÿ...
  • Page 19: Computer 1 Component Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 6.52. Computer 1 Component Command Command “C54” [CR] Select Component input in Computer 1. Detail Although projector returns “OK”, Input search is not executed with this command while Input search is set to On1 or On2, Acceptable [ACK] [CR] Response...
  • Page 20: Status Read Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 7. Status Read Command 7.1. Format 7.1.1. PC issues commands in format as below; “CR” Command [CR] Commandÿ 1 character(See Basic Status Read Command Table) 7.1.2. When a projector receives the appropriate command, it returns a character line as the required data.
  • Page 21 PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications [Details of Response] “00” [CR] Status : Power ON Normal image is on the screen. “80” [CR] Status: Standby When the status is Standby, Status Read Commands are always acceptable, but Functional Execution Commands are not acceptable except POWER ON Command.
  • Page 22 PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications information of temperature anomaly is canceled and normal operation is executed. “24” [CR] Status: Processing Power Save / Cooling Down Power management function in Setting menu works and the status goes to Power Save / Cooling Down.
  • Page 23: Input Mode Read Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 7.5. Input Mode Read Command Command “CR1” [CR] Detail Get the selected Input No. Acceptable “%1” [CR] ”1” = Computer 1 is selected Response ”2” = Computer 2 is selected “3” = Video is selected Unacceptable “?”...
  • Page 24: Lamp Mode Read Command

    PLC-XK2200 / 2600 / XK3010 Basic Serial Command Specifications 7.9. Lamp Mode Read Command Command “CR7” [CR] Get lamp mode status. Detail For 1 lamp projector, get if it is lighting or not. Acceptable “%1” [CR] “00” [CR]=Light is out. Response “01”...