14.53

Write Uncorrectable Ext (45h)

Command Block Output Registers
Register
Data Low
Data High
Feature
Current
Previous
Sector Count
Current
Previous
LBA Low
Current
Previous
LBA Mid
Current
Previous
LBA High
Current
Previous
Device
Command
Error Register
7
6
5
4
CRC UNC
0
IDN
0
0
0
V

Table 137 Write Uncorrectable Ext Command (45h)

The Write Uncorrectable Ext command is used to cause the device to report an uncorrectable
error when the target sector is subsequently read.
When the feature field contains a value of 5xh, the Write Uncorrectable Ext command causes
the device to indicate a failure when reads to any of the sectors that are contained in specified
sectors.
Theses sectors are referred to as "pseudo uncorrectable" sectors.
whenever a pseudo uncorrectable sector is accessed via a read command, the device performs
normal error recovery and then set the UNC and ERR bits to indicate she sector is bad.
When the feature field contains a value of Axh, the Write Uncorrectable Ext command causes
the device to flag the specified sector as "flagged uncorrectable". Flagging a logical sector as
uncorrectable causes the device to indicate a failure when reads to specified sectors are
performed.
These sectors are referred to as "flagged uncorrectable" sectors.
whenever a "flagged uncorrectable" sector is accessed via a read command, the device sets the
UNC and ERR bits without normal error recovery to indicate the sector is bad.
If the Uncorrectable options are set to A5h or 55h, then sectors that have been made pseudo
uncorrectable are listed as failed in the standard error logs when read back.
Uncorrectable options are set to 5Ah or AAh, then the reading of pseudo uncorrectable sectors
are not logged as an error in any standardized error logs.
The pseudo uncorrectable or flagged uncorrectable status of a sector remains through a power
cycle.
If an uncorrectable error occurs, the write will be terminated at the failing sector.
Output Parameters To The Device
Feature Current
Sector Count Current
7K200 SATA OEM Specification
7 6 5 4 3 2 1 0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
V V V V V V V V
-
1
-
-
-
-
-
0 1 0 0 0 1 0 1
3
2
1
0
0
ABT T0N AMN
0
V
0
0
Uncorrectable options
55h : Create a pseudo uncorrectable error with logging
5Ah: Create a pseudo uncorrectable error without logging
A5h: Create a flagged error with logging
AAh: Create a flagged error without logging
Other: Reserved (command is aborted)
The number of continuous sectors to be marked low order, bits (7:0).
Command Block Input Registers
Register
-
Data Low
-
Data High
-
Error
-
Sector Count
HOB=0 -
HOB=1 -
LBA Low
HOB=0 V V V V V V V V
HOB=1 V V V V V V V V
LBA Mid
HOB=0 V V V V V V V V
HOB=1 V V V V V V V V
LBA High
HOB=0 V V V V V V V V
HOB=1 V V V V V V V V
-
Device
Status
7
6
5
BSY RDY DF DSC DRQ COR IDX
0
V
0
169/173
7 6 5 4 3 2 1 0
-
-
-
-
-
-
-
-
-
-
...See Below...
-
-
-
-
-
-
-
-
-
-
-
-
-
...See Below...
Status Register
4
3
2
V
-
0
In this case
In this case
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
0
ERR
0
V
If the

Hide quick links: