Installation Guide Color CCTV Camera WV-CS580/G Model No. WV-CS584E Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. The model number is abbreviated in some descriptions in this manual.
Page 2
We declare under our sole responsibility that the product to which Wij verklaren als enige aansprakelijke, dat het product waarop this declaration relates is in conformity with the standards or other deze verklaring betrekking heeft, voldoet aan de volgende normative documents following the provisions of Directives normen of andere normatieve documenten, overeenkomstig de 2006/95/EC and 2004/108/EC.
Important safety instructions 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
AND/OR THE CORRESPONDING PRODUCT (S). Disclaimer of warranty IN NO EVENT SHALL Panasonic System Networks Co., Ltd.BE LIABLE TO ANY PARTY OR ANY PERSON, EXCEPT FOR REPLACEMENT OR REASONABLE MAINTENANCE OF THE PRODUCT, FOR THE CASES, INCLUDING BUT NOT LIMITED TO BELOW: (1) ANY DAMAGE AND LOSS, INCLUDING WITHOUT LIMITATION, DIRECT OR INDIRECT, SPECIAL, CONSEQUENTIAL OR EXEMPLARY, ARISING OUT OF OR RELATING TO THE PRODUCT;...
Features Privacy zone function Super Dynamic 6 (SUPER-D6) The privacy zone function can mask specific areas of SUPER-D6 can capture clear images of subjects the scene from view. whose illumination is extremely different. Patrol function New DSP for high sensitivity The patrol function can store manual camera move- A new noise reduction system lowers minimum illumi- ment routines for automatic playback.
Precautions The following points as well as the contents of "Warning" Do not damage the power cable. and "Caution" shall be observed. Do not damage, fabricate, twist, stretch, bundle, or forcibly bend the power cable. Do not place heavy Refer installation work to the dealer. objects.
Page 8
[Precautions for use] About the self-diagnosis function When this product malfunctions due to exogenous This product has no power switch. noise, etc. for 30 seconds or more, the product will automatically reset and will return to normal state. When When turning off the power, turn off a circuit breaker. the product is reset, initialization will be carried out as when the power of the product is turned on.
RS485, alarm in, alarm out) can exit out the "Warning" and "Caution" shall be observed. side or the top of this product. Panasonic assumes no responsibility for injuries or • When using the top cable exit confi guration, drill a property damage resulting from failures arising out hole in the ceiling to allow passage of the cables.
Page 10
Screw tightening The screws and bolts must be tightened with an appropriate tightening torque according to the material and strength of the installation area. Do not use an impact driver. Failure to observe this may cause overtightening and consequently damage to the screws.
Major operating controls Alarm Input Connector Alarm Output Connector Camera Mounting Base Video Output Connector Data Port (RS485) Power Cable Safety Wire Decorative Cover Camera Dome Fix Ring Lens The lens cannot be replaced. Dome Cover The dome cover is easily damaged, And should be handled with care.
DIP switch settings Important: • Before setting up the camera for a configuration where the camera's RS485 data port is used for camera control (pan, tilt, etc.) by the system controller, the camera's DIP switches must be configured to specify the unit number and communication parameters.
Unit Number (DIP Switch 1) The factory default settings of these DIP switches are all OFF. (Coaxial Multiplex System) Configuration for using Panasonic Protocol Unit Unit Unit DIP Switch 1 DIP Switch 1 DIP Switch 1 Number Number Number...
Page 14
Unit Unit Unit DIP Switch 1 DIP Switch 1 DIP Switch 1 Number Number Number Configuration for using Pelco protocol Unit Number Unit Number Unit Number Unit Number Unit Number Unit Number Pelco-P Pelco-D Pelco-P Pelco-D Pelco-P Pelco-D [RS485 SETUP] Menu ** RS485 SETUP ** Using a joystick, etc., set the unit number (32 to 96).
Note: • When using the Unit Number 1 to 96 of Panasonic Protocol and using the Unit Number 32 to 96 of Pelco-D protocol, the unit number setting needs to be configured using the RS485 SET UP menu. For details about configuring this setting, refer to the operating instructions (PDF).
Camera Installation When installing the camera on a wall or a ceiling, please read the important notice below. Important: • Procure 4 screws (M4) to secure the camera to a wall or a ceiling according to the material of the installation area.
Preparing the Camera and 2. Rotate the camera mounting base unit in the direction indicated by the arrow and remove it. Decorative Cover for Side Cable Exit 15° The camera and decorative cover should be prepared as shown below when mounting the camera on a Rotate Pull the camera ceiling or wall with its cables (power, video output,...
Page 18
5. Connect the cables. 10.Separate the two parts of the decorative cover (comes with camera). Please refer to page 20 for the details of connections. Press upwards on the decorative cover at the points 6. Attach the safety wire for securing the camera to the marked (indicated by the arrows, in the camera mounting base.
Uninstalling the Camera 3. Remove the safety wire from the camera mounting Caution: base. • Make sure you perform the steps below carefully and exactly when uninstalling the camera and decorative cover. Failure to do so creates the risk of damage to the camera. ...
Connections Precautions • The following connections should be made by qualified service personnel or system installers in accordance with all local codes. • See the reverse side of the cover page for main lead connection. • Turn off the power at the fuse box before starting the installation work, or it so could result in fire, electric shock, personal injury, and material damage.
Page 21
Alarm In/Out Ratings Alarm In : 5 V DC pull-up input. Drive capacity of at • 24 V AC Power Supply Connection lease 0.2 mA required. Recommended wire gauge sizes for 24 V AC line OFF : 4 V to 5 V , or open ON : 1 V DC or less, or short Copper wire size Alarm Out : Open collector output.
Troubleshooting Before requesting service, check the following symptoms to see if you can solve the problem yourself. If the countermeasures described below do not correct the problem, or if the symptoms you are experiencing are not covered here, contact a quality service person or system installer. Cause and Recommended Action Reference Pages Problem...
Page 23
Problem Cause and Recommended Action Reference Pages Operating • Check the white balance setting. Instructions Operating • Use the special setup menu to adjust picture quality. Instructions Poor picture color • Is the dome cover or lens of the camera dirty? If so, clean them.
Page 24
Problem Cause and Recommended Action Reference Pages Black line appears in • Whether or not the connected system controller is the image set as multiplex vertical driver (VD2)? Operating Menu settings will not • Is the password lock function turned on? change.
Page 25
Problem Cause and Recommended Action Reference Pages The camera movement modes (OFF, SEQ, Operating SORT, AUTOPAN, • Check the self return function. Instructions PATROL, AUTOTRACK) setting changes. Camera position is Operating different from the • Perform REFRESH from the special setup menu. Instructions preset position setting.
Specifications General WV-CS580 WV-CS584 Power Requirements 220 V - 240 V AC, 50 Hz 24 V AC, 50 Hz Power Consumption 4.6 W 4.3 W Pick-up Device 1/4-type interline transfer CCD 976 (H) × 582 (V) Effective Pixels 3.66 mm (H) × 2.73 mm (V) Scanning Area Signal Synchronization...
Main Functions Controller Interface Coaxial Multiplex System, RS485 Control Functions Pan and tilt, zoom and focus, 256 preset positions, home position, patrol ON (LOW), ON (MID), ON (HIGH), OFF Title (ID) ON, OFF (Preset ID, camera ID, area title: 16 alphanumeric characters) Zoom Speed around 6.0 seconds (TELE to WIDE) in manual mode Zoom Limit...
Page 28
Information on Disposal for Users of Waste Electrical & Electronic Equipment (private households) This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take these products to designated collection points, where they will be accepted on a free of charge basis.