Step
5
Check the above sensor for proper connection.
Is the above sensor connected properly?
6
Check the sensor (fuser output) for proper operation.
1. Enter the diagnostic mode
2. Select Base sensor test
3. Observe the line item "exit"
Caution: The area around the actuator is very hot. Allow the
fuser area to cool before proceeding.
Does the display on the operator panel, change every time
the sensing area of the above sensor is interrupted or
blocked?
7
Check the above sensor for proper connection.
Is the above sensor connected properly?
8
Perform a print test and check the main motor assembly.
Is the media properly transported and able to reach the
sensor (fuser output)?
9
Check the aligner assembly for obstructions.
Is the above component free from obstructions?
10
Perform a print test.
Does the problem remain?
Sensor (input) early jam service check
Use this procedure for the following jams:
• 200.04
Step
1
Check media origination.
Did the media originate from the MPF?
2
Check the MPF pick roll assembly.
Is the above component free of excess wear and
contamination?
Check
• 200.06
• 200.08
Check
Yes
Replace the
Replace the
sensor (input).
connection.
"Sensor
Go to
(input) removal"
on page
4-71.
Go to step 8.
Go to step 7.
Replace the fuser
Replace the
unit assembly.
connection.
Go to
"Fuser unit
assembly
removal" on
page
4-22.
Replace the main
Replace the
drive motor
connection.
assembly.
Go to
"Output
cover assembly
removal" on
page
4-54.
Go to step 10.
Remove
obstructions.
Contact next
Problem solved.
highest level of
tech support.
• 200.14
• 200.33
Yes
Go to step 2.
Go to step 5.
Go to step 3.
Clean or replace
the MPF pick roll
assembly.
Go to
roll assembly
removal" on
page
Diagnostic information
No
No
"MPF pick
4-37.
2-127