JTP75SP
Cutout width
28-1/2'' MIN.
5
GE
30" Built-In Convection/Thermal Wall Oven
®
28-5/8'' MAX.
Dimensions and Installation Information (in inches)
A
B
KW Rating
Conduit
240V
9.0
(72"
long)
208V
6.8
Breaker Size
Cutout height
51-13/16" MIN.
240V
40 Amps
D
51-15/16" MAX.
208V
40 Amps
A
Note: Cabinets installed adjacent to wall ovens
21
must have an adhesion spec of at least a 194°F
temperature rating.
Note: If marks, blemishes or the cutout opening is
B
Minimum cutout location
visible above the installed oven, it may be necessary
12" from the floor.
to add wood shims under the runners and front trim
C
until the marks or openings are covered.
Cabinet
Door handle protrudes 3" from door face. Cabinets
width 30"
and drawers on adjacent 45° and 90° walls should
be placed to avoid interference with the handle.
Installation Information: Before installing, consult
installation instructions packed with product for current
dimensional data.
Electric wall ovens are not approved for installation
with a plug and receptacle. They must be hard wired in
accordance with installation instructions.
For answers to your Monogram,
®
GE
appliance questions, visit our website at
®
ge.com or call GE Answer Center
800.626.2000.
Cutout depth
23-1/2" MIN
Junction box
location
47" to
bottom of
junction box
Suitable
bracing
to support
runners
Cabinet
A – Overlap of oven over side of edges of cutout
B – Overlap of oven at top and bottom of cutout
Oven
C – Overall depth*
D – Overall height with trim
Overall height without trim
E – Overall width
*Depth including door handle is approximately 26-6/10" min. to
26-9/10" max.
GE Profile
™
or
service,
®
C L
2 x 4 or
equivalent
runners
21-5/8"
over centerline
of cabinet
(must support 325 lbs.)
30"
11/16"-3/4"
1"
21" minimum
Door Opening
23-1/2"
Allowance
53-3/8"
52-7/8"
29-3/4"
E
Conduit
48-1/2"
D
21
C
Cabinet
width 30"
MOST 30'' WALL CABINETS CAN BE USED WITH THIS UNIT.
THE OPENING BETWEEN THE INSIDE WALLS MUST BE AT LEAST 28-1/2'' WIDE.
Specification Created 5/09
Cutout width
28-1/2'' MIN.
5
28-5/8'' MAX.
Cutout depth
23-1/2" MIN
Junction box
location
A
B
47" to
bottom of
junction box
Cutout height
51-13/16" MIN.
51-15/16" MAX.
A
B
Minimum cutout location
12" from the floor.
Listed by
Underwriters
Laboratories
320137
Suitable
bracing
to support
runners
Cabinet
A – Overlap o
B – Overlap o
Oven
C – Overall de
D – Overall he
Overall he
E – Overall wi
*Depth includin
26-9/10" max.