GE Security www.gesecurity.com Part Numbers: 600-1021-95R 600-1022-95R 600-1040 600-1042 Concord 4 Series Security Systems National Security Systems Inc (800)457-1999 466-2183 Rev B June 2005 user guide...
Page 2
4,855,713. Except expressly provided herein, the purchase of this product shall not constitute a license or otherwise provide a right to practice a method covered by any of the identified patents. GE Security hereby grants the purchaser of this product a limited, non-exclusive license to practice the methods patented in the identified patents solely with products manufactured, sold or licensed by GE Security.
Commands at a Glance Disarm the system. CODE or 1 Cancel an accidental alarm. Arm to Level 2—STAY.* Arm to Level 3—AWAY.* Send a police alarm. Send an auxiliary alarm. Send a fire alarm. 8573G51A.D Arm system with No Delay.* Arm system for Latchkey.* Bypass a sensor.* Indirectly:...
Contents Commands at a Glance - Getting to Know Your Security System Panel ... 1 Touchpads ... 1 Door/Window Sensors ... 1 Motion Sensors ... 1 Environmental Sensors ... 1 Optional System Components ... 1 Communicating with the System Alphanumeric and Fixed Display Touchpads ... 2 Wireless Handheld Touchpad ...
Page 6
Checking the Status of Your System ... 11 Short System Status ... 11 Full System Status ... 11 Panic Alarms Fire Panic Alarm ... 12 Lighting During a Fire Panic Alarm ... 12 Police Panic Alarm ... 12 Lighting During a Police Panic Alarm ... 12 Auxiliary Panic Alarm ...
Page 7
Example 1 of One Day Rollover ...21 Example 2 of One Day Rollover ...21 Multiple Day Rollover ... 21 Example of Multiple Day Rollover ...21 Attaching Time Schedules ... 21 Time Schedules and Partitions ... 22 Advanced Light Control Controlling Lights By Time Schedule ... 22 Controlling Lights with Sensors ...
Page 8
Arming and Disarming Another Partition ... 29 Programming Another Partition ... 29 Arming and Disarming Multiple Partitions at the Same Time ... 29 Notes on Arming/Disarming Multiple Partitions from Alphanumeric and Fixed Display Touchpads ...30 Notes on Arming/Disarming Multiple Partitions from Keychain Touchpads ...30 Macro Keys System Information Viewing the Event Buffer...
Page 9
Accidental Smoke and Fire Alarms ... 46 Dialer Abort ... 46 Doors and Delay Time Settings ... 46 System Features... 46 If the Power Goes Out ... 47 No Activity Time ... 47 Resetting the Smoke Detector ... 47 System Information ... 47 Paging ...
If you would rather use an actual key (Figure 3) to arm and disarm the system, your security dealer can install a special key and keyswitch in your home. S y s t e m i s O K Alphanumeric Fixed Display Figure 2. Touchpads Figure 3. Arm/Disarm Key Wireless Handheld Keychain Concord 4 Series Security Systems...
Your system can dial the phone numbers of five different pagers to notify pager holders of important system events, including: • System disarming • System arming • Trouble conditions • Alarm conditions For more information, see “Notification By Pager”. Concord 4 Series Security Systems System Status Red Armed LED Flashing Flashing Green Ready LED...
• If you have pets, ask your installer if you need pet lenses in your motion detectors. Concord 4 Series Security Systems Fire button(s) for 2 seconds on the nearest touchpad or activate a Do not re-enter the building if sirens stop. The sirens in your system are pro- grammed to stop after a certain amount of time.
2. Enter your Access Code. Touchpads display date and time or programmed text and the sys- system. tem sounds one long beep. To disarm to Level 1—OFF using a keychain touchpad: Press the . Touchpads display “ENTER CODE.” . Touchpads display “ENTER CODE.” Unlock button. Concord 4 Series Security Systems...
Return within two minutes and close the door. The system will rearm to 2—STAY. Concord 4 Series Security Systems at any touchpad. Touchpads display, “ENTER CODE.” Lock button once to go from Level 1 to Level 2.
Lock button once to arm to Level 2, press it twice for Level 3, or CODE CODE . The system sounds two or three short beeps. . Touchpads display, “ARMED TO STAY NO DELAY” or “ARMED . While the Chime feature is on, Concord 4 Series Security Systems...
2. Arm your system to the desired level. Concord 4 Series Security Systems The system detects that no one opened and closed a delay door within the delay time. It assumes that someone is still inside and arms to 2—STAY to prevent a false alarm.
You cannot turn on a specific light using a keychain touchpad. CODE is labeled Bypass) (Bypass). Touchpads with displays show, “BYPASSED ZONES button once to arm the system and again to bypass open sensors. is labeled Status.) Lights button. + light number. Concord 4 Series Security Systems...
Panic alarms are easily activated from any touchpad to quickly alert the central monitoring sta- tion to a Fire, Police, or Auxiliary emergency so the correct personnel can be dispatched immedi- Concord 4 Series Security Systems + output number. If the output was already activated, it will is labeled Status.)
Continuous tone Auxiliary Rapid beeps Fire button(s) for 2 seconds. Police button(s) for 2 seconds. Lock and Unlock buttons together for 2 seconds. Auxiliary button(s) for 2 seconds. Lights and Star buttons together for 2 seconds. Concord 4 Series Security Systems...
You cannot enter User Programming with a Regular User code. The Touchpad Tamper Feature The installer can program your system to activate a Police alarm in the case of possible touchpad tampering. Concord 4 Series Security Systems 1234, 1111 2222 , etc.
+ System or Partition Master where nn is the user 00 through 15. , then #. CODE + System or Partition Master where nn is the user 00 through 15. CODE + System or Partition Master Concord 4 Series Security Systems...
2. Press 3. Enter the correct time in 24-hour format (4 digits--see Figure 4), then press the current time is 7:23 a.m., press Concord 4 Series Security Systems where nnn is user 000 through 229. to exit the programming menus.
CODE + System or Partition Master . For example, if the current date is to raise the pitch. CODE + System or Partition Master CODE + System or Partition Master Concord 4 Series Security Systems...
The high and low settings you enter do not control heating and cooling systems, but determine the point at which the furnace or air conditioner is activated (see Figure 5). Concord 4 Series Security Systems Medium High...
Police Panic Phone Test Auxiliary Panic Event Buffer Full Touchpad Low Battery CODE + System or Partition Master Low Level Reports AC Power Failure CPU Low Battery Auto Phone Test CPU Back in Service Phone Failure Concord 4 Series Security Systems...
This number identifies who or what is causing the event. Code 001 — 096 600 — 829 830 — 835 Concord 4 Series Security Systems Event Code Last four digits of central station account number Sensor number or user number Figure 6.
+# to exclude the day in the schedule. to move to the next day of the week or press once. . The touchpad displays the new stop time. and repeat steps 2–8 to define another to exit the programming menus. Concord 4 Series Security Systems...
See “Controlling Outputs By Time Schedule” for information on attaching time schedules to outputs. • See “Schedule Arming” for information on attaching schedules to Arming. Concord 4 Series Security Systems Example 2 Example 1 Figure 8. Time Schedule Rollover Examples...
System or Partition Master 2. Press 3. The touchpad displays “AWAY.” Concord 4 Series Security Systems until the light number (1–9) you would like to activate appears. to assign another light to a sensor or press CODE until the touchpad displays “ATTACH LIGHTS TO SENSORS”...
(“ON”) to arm the panel. to make the time schedule inactive. to go to the next time schedule, if needed, and turn the schedule on or off for arming to exit the pro- Concord 4 Series Security Systems...
1. At an alphanumeric or fixed display touchpad, enter the programming menus by pressing + System or Partition Master 2. Press Concord 4 Series Security Systems Only , or press the Lock button on a keychain touchpad after arming , or press the Lock button on a keychain touchpad after arming...
5. ) is pressed after the arming keypress sequence. CODE button when the system is armed to level 3—AWAY. Concord 4 Series Security Systems to exit the pro-...
Feature Turning the Download feature on gives the dealer remote access to your system in order to: • Update your account. Concord 4 Series Security Systems CODE 0620 when the touchpad displays “EXCEPTION OPENING” or until the touchpad displays “EXCEPTION CLOSING” or to assign the time schedule to the event.
. The dealer will be able to access your system remotely if necessary. . The dealer will not be able to access your system remotely. to exit the programming menus. CODE + System or Partition Master Concord 4 Series Security Systems...
1. Press 1 on any touchpad assigned to the partitions you want to arm. The display shows “ENTER CODE”. 2. Enter your Access Code. The display shows all the partitions that will be disarmed. Concord 4 Series Security Systems CODE the desired partition number (1 - 6)
Lock button. Unlock button. Lock button attempting to arm Partitions 1 and 2, a Unlock button a second time (within the five minute protest period) to dis- cancels all alarms in the associated par- Lock Concord 4 Series Security Systems...
• Press the * key to exit Viewing Event History. Concord 4 Series Security Systems to display the system number. For example, “N – nnnnnnn,” or “SYSTEM NUM- to display the system level. For example, “L nnnn,” or “SYSTEM LEVEL nnnn.”...
Page 42
Lost Event (buffer overflow) LOST EVENT Main Unit Tamper MAIN UNIT TAMPER Memory Clear MEMORY CLEAR Memory Failure MEMORY FAILURE No Activity Alarm ACTIVITY ALARM Current Display Partition Arming Level Bus Unit Zone Number Source User Concord 4 Series Security Systems...
Page 43
Line two of the display also contains “P-C” where P is the previous arming level and C is the current arming level. User information is shown in the following table. U001 - U096 Concord 4 Series Security Systems Current Display...
Source Premise Phone Phone During Conversation Remote Phone Auto Stay Arming Automation Module Keyswitch Arming Zone System Keychain Touchpad Wireless Touchpad Alphanumeric Touchpad Fixed Display Touchpad by the installer. If your prefix has been changed, Concord 4 Series Security Systems...
Touchtone Phone System Operation Phone operation of your system involves 2 steps: Local Phone Access Remote Phone Access Concord 4 Series Security Systems (your designated Phone Command Prefix). CODE . You hear a short status message, such as, “System is OK.”...
(on-site only) or Wait 5 seconds after picking up a local phone. Output number (1–6) repeatedly, regardless of your phone command prefix key. + Sensor Number CODE even if you Concord 4 Series Security Systems...
MINUTES LEFT.” When less than 5 minutes remain in Test Mode time, the system sounds a short beep every 60 seconds. System test 3. Follow the test procedure for each device as listed in the following table. Concord 4 Series Security Systems . The system responds by returning a dial tone. CODE...
SENSOR nn OK Zones nn OK SENSOR nn OK Zones nn OK SENSOR nn OK Zones nn OK SENSOR nn OK POLICE PANIC OK Zones nn OK SENSOR nn OK Zones nn OK SENSOR nn OK Concord 4 Series Security Systems...
The table on the next page describes the conditions under which trouble beeps occur and when they begin. (These sounds are heard from interior sirens and touchpads if available.) Concord 4 Series Security Systems CODE + System or Partition Master...
Schedules”. • Check the User Sheets in Appendix A to see in which partition the light is set up to be active. for a system status and for clues to the problem. . The system Concord 4 Series Security Systems...
Page 51
There is a problem with the power supplied to parts of the system. Call your security dealer for service. BUS FAILURE UNIT NN There is a problem with one of the peripheral devices in your system. Call your security dealer for service. Concord 4 Series Security Systems Trouble Condition...
Sensors than will fit on this sheet, make copies of this sheet and keep all the infor- mation together. Sensor Name Concord 4 Series Security Systems Ptn. HW / WL / TP (1-6) (circle one) HW / WL / TP...
Active for Partition: 1 2 3 4 5 6 • Latchkey User: Y N Keychain Touchpad 4 • Active for Partition: 1 2 3 4 5 6 • Latchkey User: Y N Concord 4 Series Security Systems ¨ ¨ ¨ ¨ Figure 10. Keychain Touchpad 2 ¨ ¨...
No. If I re-enter the armed premises during the Exit Delay time, it will con- tinue to count down and I must disarm the system. Yes. I can use a key to arm the system. The switch is located: ______________________________________________________________ Ptn. Entry Delay Exit Delay Concord 4 Series Security Systems...
System number System level Software version Concord 4 Series Security Systems No Activity Feature Yes. If there is no activity in my system for ____ hours (1-42, default 24), the system will send a No Activity report to the central station.
Record the house codes for each partition and location of each light below. Partition 1—House Code______ Light Partition 3—House Code______ Light Pagers Partition 2—House Code______ Location of Light Light Partition 4—House Code______ Location of Light Location of Light Concord 4 Series Security Systems...
1 short, high-pitched beep when a sensor/touchpad tests OK. 1 short, low-pitched beep when a sensor/touchpad fails a test. Contact your dealer for information or service. 1 short beep every minute during the last 5 minutes of sensor test. Alarm Sound Beep Sound Concord 4 Series Security Systems...
Figure 13 is an example of a multi-level floor plan. Use this example as a guide to draw your own floor plan. Concord 4 Series Security Systems Warning!If you arrive at the premises and hear sirens, do not attempt to enter the build-...
Show all building levels. Show exits from each room (two exits per room are recommended). Show the location of all security system components. Show the locations of any fire extinguishers. Figure 13. Floor Plan Example Concord 4 Series Security Systems...
If you have any questions about your security system or if it ever needs servicing, please contact your security dealer. Company Name _____________________________ Address ____________________________________ City _______________ State _____ Zip __________ Phone Number (_____) _______________________ Contact Name _______________________________ Warning!Security systems and devices cannot compensate you for life or property losses. Concord 4 Series Security Systems...
To change or assign a user access code: 1. Enter the programming menus by pressing 2. Press Concord 4 Series Security Systems Figure 14. Navigating Menus on Your Touchpad until the touchpad displays “USER CODES,” then press ‚...
“USER 04” or . The deleted code to exit the programming menus. CODE + System or Partition Master CODE + System Master Concord 4 Series Security Systems . For exam- . (You can- . For exam- until the...