hit counter script

Display Clock - HP 6125G Command Reference Manual

6125 blade switch series fundamentals command reference
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use display alarm to display device alarms.
Examples
# Display device alarms.
<Sysname> display alarm
Slot
Level
6
ERROR
6
ERROR
6
ERROR
3
WARNING
Table 19 Command output
Field
Slot
Level
Info

display clock

Syntax
display clock [ | { begin | exclude | include } regular-expression ]
View
Any view
Default level
1: Monitor level
Parameters
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Info
Fan 2 is absent.
Power 2 is absent.
The board in slot 10 is faulty.
The temperature of sensor 3 exceeds the lower limit.
Description
ID of the alarming device
Alarm severity level, including ERROR, WARNING, NOTICE,
and INFO
Detailed alarm information