hit counter script

HP 634041-006 Deployment Manual page 88

Solutions with 6gb sas bl switches and external sas storage enclosures
Table of Contents

Advertisement

NOTE:
Restrictions exist, depending on the controller, storage enclosure, and drive model. For
more information, see
(page 77)
IMPORTANT:
appearance to a dual-domain, high-performance configuration. However, because of the single
I/O module in each MDS600/D6000 drawer, it is for single-domain use only. The additional
switch is used in conjunction with the cabling scheme and zone group strategy to obtain best
possible performance.
88
Deployment examples
"External SAS device, controller, drive, and cabling support matrices"
Because it includes two HP 6Gb SAS BL Switches, this configuration is similar in
Devices and quantities
MDS600/D6000 storage enclosures: 2
I/O modules: 4
BladeSystem c7000 enclosures: 1
6Gb SAS BL Switches: 2
Server blade types: half-height and full-height
Connection details
Switch in interconnect bay 5:
Port 1: to storage drawer 2, primary
I/O module, port 1
Port 2: to storage drawer 2, primary
I/O module, port 2
Port 5: to storage drawer 2, primary
I/O module, port 1
Port 6: to storage drawer 2, primary
I/O module, port 2
Switch in interconnect bay 6:
Port 1: to storage drawer 1, primary
I/O module, port 1
Port 2: to storage drawer 1, primary
I/O module, port 2
Port 5: to storage drawer 1, primary
I/O module, port 1
Port 6: to storage drawer 1, primary
I/O module, port 2