  • Page 2 Safety Information BEFORE YOU BEGIN WARNING: TO REDUCE THE RISK OF F IRE, ELECTRICAL S HOCKORINJURY TO PERSONS, O BSERVE Readthese instructionscompletely and carefully. THE FOLLOWING: "IMPORTANT-save these instructions A. Use this unit only in the manner intended by the local inspector's use.
  • Page 3: Table Of Contents

    Design Information CONTENTS Wall-Mounted Installation - Recirculating Ductwork, Wiring Locations ..............14 Design Information Step 1, Install Framing for Hood Support .......... 14 Product Dimensions and Clearances ..........3 Step 2, Install Mounting Bracket ............15 Installation Options ................3 Step 3, Prepare the Hood ..............
  • Page 4: Advance Planning, Ductwork, Framing

    Installation Preparation ADVANCE PLANNING • Determine the exact location of the vent hood. • Use metal ductwork only. These hoods must use 6" round duct. It can transition to 3-1/4" x 12", • Plan the route for venting exhaust to the outdoors. reducing the maximum equivalent duct length to •...
  • Page 5: Duct Fittings

    Installation Preparation Total DUCT FITTINGS Equivalent Quantity Equivalent Use this chart to compute maximum Duct Piece Dimensions Length* Used Length permissable lengths for duct runs to outdoors. Round, I ft. straight (per foot length) NOTE: Do not exceed maximum permissable equivalent lengths! 3-1/4"...
  • Page 6: Tools And Materials Required

    Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) [] Tape measure [] Knife Gloves Spirit level [] Spirit level Measuring Tape [] Wire cutter/stripper [] Wire nuts [] Electric drill with 1/8"and 3/8" bits Knife [] Phillips and flat blade screwdrivers [] Hammer Pliers Electric drill...
  • Page 7: Wall Mount Installations

    Installation Preparation WALL MOUNT INSTALLATIONS These hoods may be installed onto a wall or below a Actual *Possible wall cabinet. *Possible VENTED RECIRCULATING Celing Height Installation Height Installation Height • Telescopic duct covers are provided to conceal the ductwork, running to the ceiling. 7'11"...
  • Page 8: Check Installation Hardware

    Installation Preparation CHECK INSTALLATION HARDWARE Locate the hardware accessory box packed with the hood and check contents. 4 wood screws 4 wall fasteners Duct bracket Air deflector for recirculating installations only Mounting bracket Discharge damper 29 j4 1 charcoal filter for recirculating installations 3 Phillips head screws to secure...
  • Page 9: Ductwork, Wiring Locations

    Installation Instructions WALL-MOUNTEDINSTALLATION--VENTEDTO THE OUTSIDE DUCTWORK, WIRING LOCATIONS INSTALL FRAMING FOR HOOD SUPPORT Determine the exact location of the vent hood, • Locate the template packed with the literature. IMPORTANT- Framing must be capable of - Measure 36" from the floor to the top of the cooking supporting 100 Ibs.
  • Page 10: Step 2, Install Mounting Bracket

    Installation Instructions WALL-MOUNTEDINSTALLATION--VENTEDTO THE OUTSIDE INSTALL MOUNTING BRACKET INSTALL DUCT BRACKET This vent hood must be secured to the horizontal The duct bracket must be intalled against the ceiling. support or wall studs. This bracket will hold the duct cover in place atthe top. •...
  • Page 11: Step 4, Prepare The Hood

    Installation Instructions WALL-MOUNTEDINSTALLATION--VENTEDTO THE OUTSIDE PREPARE THE HOOD MOUNT THE HOOD • Remove the hood from the box. Remove packaging Install a wood screw Mounting and tape, on each side of the b racket _ <--- Remove2 side mounting frame _ Electrical j cover screws panel _-...
  • Page 12: Step 6, Connect Ductwork

    Installation Instructions WALL-MOUNTEDINSTALLATION--VENTEDTO THE OUTSIDE CONNECT DUCTWORK Air flow • Install ductwork, making connections in direction of airflow as illustrated. • Push duct over the exhaust outlet and damper. Ducttape over seam • Secure joints in ductwork with sheetmetal screws. and screw Screw •...
  • Page 13: Step 8, Install Duct Covers

    Installation Instructions WALL-MOUNTEDINSTALLATION--VENTEDTO THE OUTSIDE INSTALL DUCT COVERS INSTALL FILTERS • Place the decorative duct • Remove protective film on the filters. covers on top of the hood. Mounting,,,_"_ NOTE: The inside (upper) duct piece has holes on one screws end.
  • Page 14: Wall-Mounted Installation - Recirculating

    Installation Instructions WALL-MOUNTED INSTALLATION--RECIRCU LATING DUCTWORK, WIRING LOCATIONS INSTALL FRAMING FOR HOOD SUPPORT • Determine the exact location of the vent hood, • Locate the template packed with the literature. IMPORTANT: Framing must be capable of • Measure 36" from the floor to the top of the cooking supporting 100 Ibs.
  • Page 15: Step 2, Install Mounting Bracket

    Installation Instructions WALL-MOUNTED INSTALLATION--RECIRCU LATING I_ INSTALL MOUNTING BRACKET PREPARE THE HOOD This vent hood must be secured to the horizontal • Remove the hood from the box. Remove packaging support or wall studs. and tape. • With the template taped in place, use a punch to mark all mounting screw locations.
  • Page 16: Step 4, Mount The Hood

    Installation Instructions WALL-MOUNTED INSTALLATION--RECIRCU LATING MOUNT THE HOOD SIZE AND CUT DUCT PIECE (cont.) Install a wood screw Mounting on each side of the bracket • Cut the duct piece to size and mounting frame slip onto the bottom of the duct connector.
  • Page 17: Step 6, Connect Electrical

    Installation Instructions WALL-MOUNTED INSTALLATION--RECIRCU LATING CONNECT ELECTRICAL Verify that power is turned off at the source. • Remove junction box cover and knockout. • Use a conduit connector to secure the conduit to WARNING: If house wiring is not 2-wire the junction box.
  • Page 18: Step 8, Install Filters

    Installation Instructions WALL-MOUNTED INSTALLATION--RECIRCU LATING INSTALL FILTERS FINALIZE INSTALLATION • Remove all packaging materials. Charcoal filter • Refer to the Owner's Manual for operating • Remove protective film on the filters. instructions. • Install the black charcoal filter into the center opening, Metal grease filters •...
  • Page 19: Under-Cabinet Installation

    Installation Instructions UNDER-CABINET INSTALLATION CABINET REQUIREMENTS DUCTWORK, WIRING • Determine the exact location of the vent hood, This hood may be installed beneath a wall-mounted cabinet. • Locate the Rear Wall Template packed with the literature. • If the cabinet has been installed, it must be removed so that wall framing supports can be added.
  • Page 20: Step 1, Install Framing For Hood Support

    Installation Instructions UNDER-CABINET INSTALLATION INSTALL FRAMING FOR HOOD PREPARE THE HOOD SUPPORT • Remove the hood from the box. Remove packaging and tape. IMPORTANT: Framing must be capable of supporting 100 Ibs. Electrical cover screws --_" _rl'<----Remove 2 side panel / View from rear cleats •...
  • Page 21: Step 3, Cut The Opening

    Installation Instructions UNDER-CABINET INSTALLATION CUT THE OPENING INSTALL SIDE "L" BRACKETS If the cabinet has been installed, remove it from the wall. • Use the Top Cabinet Template to locate and cut a hole in the bottom of the cabinet. Install 2 screws in •...
  • Page 22: Step 6, Mount The Hood

    Installation Instructions UNDER-CABINET INSTALLATION MOUNT THE HOOD COMPLETE THE INSTALLATION AND CONNECT DUCTWORK Install a wood screw on each side of the mountinc Install 2 Screws into Each Side Bracket • Carefully, lift the hood into the cabinet. Guide the Drive 2 screws into each side bracket.
  • Page 23: Step 8, Connect Electrical

    Installation Instructions UNDER-CABINET INSTALLATION CONNECT ELECTRICAL INSTALL FILTERS WARNING: If house wiring is not 2-wire • Remove protective film on the filters. with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L.