ELECTRICAL
CONNECTIONS
FOR 4-WIRE
SYSTEM
i
NON-CANAD/AN
ELECTR/C Dryer
1.
Remove the screws securing the terminal block access cover and
the strain relief mounting bracket located on the back of the dryer
upper corner.
2.
Install a U.L. approved strain relief in the entry hole of the mounting
bracket. Finger tighten the nut only at this time.
Remove the ground wire from the green ground screw located
above the terminal block.
GREEN POWER CORD
GREEN
SILVER TERMINAL
SCREW
//
TERMINAL
BLOCK
TIGHTEN
NUT
GROUND
TO THESE
WIRE
HREADS
STRAIN \
RELIEF'\
BRACKET.
>OWER
CORD
Thread a U.L approved 30 amp power cord, NEMA 14-30 type ST or
SRDT through the strain relief.
TYPI¢:AL 4
(_
BLACK
(:ONDUCTOR _"
'/
TYPICAL 4
CONDUCTOR
30 AMP NEMA 14-30 TYPE SRDT OR ST
5. Attach the green power cord ground wire to the cabinet with the
green ground screw.
Attach the white (neutral) power cord conductor from the power
cord and the neutral ground wire from the dryer harness to the
silver-colored center terminal on the terminal block. Tighten the
screw securely.
Attach the red and black power cord conductors to the outer
brass-colored terminals on the terminal block.
Do not make a sharp bend or crimp wirin_conductor
at the connections.
8. Tighten the screws securing the cord restraint firmly against the
power cord.
9. Tighten the strain relief nut securely so the strain relief does not
turn.
10. Reinstall the terminal block access cover.
GAS CONNECTION
Remove the shipping cap from gas pipe at the rear of the dryer.
NOTE; DO NOT connect the dryer to L.R gas service without
converting
the gas valve. An L.R conversion kit must be installed
by a qualified gas technician.
Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from
gas supply line to the 3/8 inch (0.96 cm) pipe located on the back
of the dryer (see pages 6 and 7). Use a 1/2 inch to 3/8 inch (1.27
cm to 0.96 cm) reducer for a connection.
Apply an approved
thread sealer that is resistant to the corrosive action of liquefied
gases on all pipe connections.
PEN / GAS FLOW POSITION
4. Test all connections by brushing on a soapy water solution. NEVER test
for gas leaks with
an open flame.
GENERAL
INSTALLATION
1. Connect the exhaust duct to outside exhaust system (see pages 2
and 3). Use duct tape to seal all joints.
With the dryer in its final position, adjust one or more of the legs
until the dryer is resting solid on all four legs. Place a level on top
of the dryer. The dryer MUST be level and resting
sofid on all
four legs.
3.
Plug the power cord into a grounded
outlet. NOTE: Check to
ensure the power is off at circuit breaker/fuse
box before plugging
the power cord into the outlet.
4.
Turn on the power at the circuit breaker/fuse
box.
Before
operating
the dryer, make sure the
dryer
area is clear and free from combustible
materials,
gasoline,
and other
flammable
vapors. Also see that
nothing
(such as boxes,
clothing,
etc.) obstructs
the flow
of combustion
and ventilation
air.
Run the dryer through
a cycle check for proper operation.
NOTE: On gas dryers, before the burner will light, it is necessary
for the gas line to be bled of air. If the burner does not light within
4B seconds the first time the dryer is turned on, the safety switch
will shut the burner off. If this happens, turn the timer to "OFF" and
wait 5 minutes before making another attempt
to light.
6.
If your dryer does not operate, please review the "Avoid Service
Checklist"
located in your Use and Care Guide before calling for
service.
Place these instructions
in a location near the dryer for future
reference.
NOTE: A wiring diagram/tech
sheet is in an envelope attached to
the inside side panel of the dryer by the blower housing.
Pedestal
A pedestal accessory, Model
No. APWD15W,
specifically designed
for this dryer may be used when elevating the dryer for ease of use.
Failure to
use accessories certified
by the manufacturer
could result
in personal injury, property damage or damage to the dryer.
REPLA
CEMENT
PARTS
If replacements
parts are needed for your dryer, contact
the source
where you purchased your dryer, call 1-800-944-9044,
or visit our website,
www.frigidaire.com,
for the Frigidaire
Company
Authorized
Parts
Distributor
nearest you.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify proper
operation
after servicing.
Destroy
the carton
and plastic
bags after
the dryer
is
unpacked.
Children might use them for play. Cartons covered with rugs,
bedspreads,
or plastic sheets can become airtight
chambers
causing
suffocation.
Place all materials in a garbage container or make materials
inaccessible to children.
The instructions in this manual and all other literature included
with this dryer are not meant to cover every possible condition and situation
that may occur. Good safe practice and caution MUST be applied when
installing,
operating
and maintaining
any appliance.
3. Open the shutoff valve in the gassupply line to allow gas to flow
through the pipe.
8