(MFR’S VERSION A) SERVICE MANUAL COLOR TELEVISION 19A26 The above model is classified as a green product (*1), as indicated by the underlined serial number. This Service Manual describes replacement parts for the green product. When repairing this green product, use the part(s) described in this manual and lead-free solder (*2).
Hazardous Substances. From July 1, 2006, the RoHS Directive will prohibit any marketing of new products containing the restricted substances. Increasing attention is given to issues related to the global environmental. Toshiba Corporation recognizes environmental protection as a key management tasks, and is doing its utmost to enhance and improve the quality and scope of its environmental activities.
SERVICING NOTICES ON CHECKING 1. KEEP THE NOTICES 6. AVOID AN X-RAY As for the places which need special attentions, Safety is secured against an X-ray by consider- they are indicated with the labels or seals on the ing about the cathode-ray tube and the high cabinet, chassis and parts.
TABLE OF CONTENTS GREEN PRODUCT PROCUREMENT ......................A1-1 LEAD-FREE SOLDER ..........................A1-1 SERVICING NOTICES ON CHECKING ...................... A1-2 HOW TO ORDER PARTS ........................... A1-2 IMPORTANT ..............................A1-2 TABLE OF CONTENTS ..........................A2-1 GENERAL SPECIFICATIONS ........................A3-1~A3-5 DISASSEMBLY INSTRUCTIONS 1.REMOVAL OF ANODE CAP ......................B1-1 2.REMOVAL AND INSTALLATION OF FLAT PACKAGE IC ...............
GENERAL SPECIFICATIONS CRT Size / Visual Size 19 inch / 480.0mmV System CRT Type Normal Magnetic Field BV/BH +0.45G/0.18G Color System NTSC Speaker 1Speaker Position Bottom Size 3 Inch Impedance Sound Output 1.5 W 10%(Typical) --- W NTSC3.58+4.43 /PAL60Hz Tuning Broadcasting System System M System...
Page 6
GENERAL SPECIFICATIONS On Screen Menu Display Menu Type Character Picture Contrast Brightness Color Tint Sharpness Audio Bass Treble Balance BBE On/Off Stable Sound On/Off CH Set Up TV/CABLE(CABLE) Auto CH Memory Add/ Delete Language V-chip Lock On Timer CH Label Favorite CH Color Stream DVD/DTV Control Level...
Page 7
GENERAL SPECIFICATIONS G-10 Remote Unit RC-EH Control Glow in Dark Remocon Format Toshiba Custom Code 40-BF h Power Source Voltage(D.C) UM size x pcs UM-4 x 2 pcs Total Keys Keys Keys Power CH Up CH Down Volume Up Volume Down...
Page 8
GENERAL SPECIFICATIONS G-11 Features Auto Degauss Auto Shut Off Canal+ CABLE Anti-theft Rental Memory(Last CH) Memory(Last Volume) V-Chip Type USA,ORION Type Auto Search CH Allocation Just Clock Function CH Label VM Circuit Full OSD Premiere Comb Filter Lines Auto CH Memory Hotel Lock Closed Caption Stable Sound...
Page 9
Height (cm) 60 (ORION SPEC:46) Container Stuffing Sets/40' container G-17 Cabinet Material Cabinet Cabinet Front PS 94V0 DECABROM Cabinet Rear PS 94V0 DECABROM Non-Halogen Demand Eyelet Demand G-18 Environment Environmental standard requirement (by buyer) Green procurement of TOSHIBA Pb-free Phase3(Ph A3-5...
DISASSEMBLY INSTRUCTIONS 3. After one side is removed, pull in the opposite direction to 1. REMOVAL OF ANODE CAP remove the other. Read the following NOTED items before starting work. NOTE After turning the power off there might still be a potential Take care not to damage the Rubber Cap.
DISASSEMBLY INSTRUCTIONS When IC starts moving back and forth easily after REMOVAL AND INSTALLATION OF desoldering completely, pickup the corner of the IC using a FLAT PACKAGE IC tweezers and remove the IC by moving with the IC desoldering machine. (Refer to Fig. 2-3.) REMOVAL NOTE Put the Masking Tape (cotton tape) around the Flat...
Page 12
DISASSEMBLY INSTRUCTIONS INSTALLATION When bridge-soldering between terminals and/or the soldering amount are not enough, resolder using a Thin-tip Take care of the polarity of new IC and then install the new Soldering Iron. (Refer to Fig. 2-8.) IC fitting on the printed circuit pattern. Then solder each lead on the diagonal positions of IC temporarily.
SERVICE MODE LIST This unit is provided with the following SERVICE MODES so you can repair, examine and adjust easily. To enter the Service Mode, press both set key and remote control key for more than 2 seconds. Set Key Remocon Key Operations VOL.
ELECTRICAL ADJUSTMENTS 2. BASIC ADJUSTMENTS BEFORE MAKING ELECTRICAL ADJUSTMENTS 2-1: CUT OFF Read and perform these adjustments when repairing the Place the set in AV MODE without signal. circuits or replacing electrical parts or PCB assemblies. Using the remote control, set the brightness and contrast to normal position.
Page 15
ELECTRICAL ADJUSTMENTS 2-5: TINT 2-7: HORIZONTAL PHASE Receive the color bar pattern.(RF Input) Receive the monoscope pattern from the Pattern Connect the oscilloscope to TP023. Generator. Activate the adjustment mode display of Fig. 1-1 and Activate the adjustment mode display of Fig. 1-1 and press the channel button (22) on the remote control to press the channel button (05) on the remote control to select "TINT".
Page 16
ELECTRICAL ADJUSTMENTS 2-11: CONTRAST MAX Receive the color bar pattern.(RF Input) Activate the adjustment mode display of Fig. 1-1 press the channel button (17) on the remote control to select "CONT.MAX". Press the VOL. UP/DOWN button on the remote control until the contrast step No.
ELECTRICAL ADJUSTMENTS PURITY AND CONVERGENCE 3-3: STATIC CONVERGENCE ADJUSTMENTS NOTE Adjust after performing adjustments in section 3-2. NOTE Receive the crosshatch pattern from the color bar Turn the unit on and let it warm up for at least 30 generator. minutes before performing the following adjustments.
BLOCK DIAGRAM J702 J703 CH. DOWN VOL. DOWN IC1001 AN7511 MICON/CHROMA IC IC101 OEC7091C CH. UP SPEAKER SOUND AMP SP1001 VOL. UP RGB Proc.2 Q801 OSD SW CONTRAST BRIGHTNESS POWER RED OUT RGB OUTPUT Stage DRIVE Chroma Proc. Q802 CUT OFF OS101 ACC/C-BPF HV BLK...
TV POWER SCHEMATIC DIAGRAM (MAIN PCB) CAUTION :FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE SAME TYPE 4A 125V (F501) FUSE. ATTENTION :POUR UNE PROTECTION CONTINUE LES RISQUES 4A 125V D’INCEIE N’UTILISER QUE DES FUSIBLE DE MEME TYPE 4A 125V (F501). TO SOUND/AV R532 Q506...
WAVEFORMS 16 50V 20µs/div SOUND/AV 0.5V 1ms/div 1V 1ms/div 200mV 500µs/div 20 500mV 20µs/div NOTE: The following waveforms were measured at the point of the corresponding balloon number in the schematic diagram.