hit counter script
Mitsubishi Electric SLZ-KA25 Installation Manual
Mitsubishi Electric SLZ-KA25 Installation Manual

Mitsubishi Electric SLZ-KA25 Installation Manual

Hide thumbs Also See for SLZ-KA25:

Advertisement

Air-Conditioners
SLZ- KA25, KA35, KA50VAQ
KA25, KA35, KA50VAL

INSTALLATION MANUAL

For safe and correct use, please read this manual and the outdoor unit installation manual thoroughly before
installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil
extérieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente
manuale ed il manuale d'installazione dell'unità esterna.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ÛˆÛÙ‹ Î·È ·ÛÊ·Ï‹ ¯Ú‹ÛË, ‰È·‚¿ÛÙ ÚÔÛÂÎÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ, ηıÒ˜ Î·È ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ
ÂÁηٿÛÙ·Û˘ Ù˘ Â͈ÙÂÚÈ΋˜ ÌÔÓ¿‰·˜, ÚÈÓ ·fi ÙËÓ ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÙÈÎÔ‡.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
exterior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Läs bruksanvisningen och utomhusenhetens installationshandbok noga innan luftkonditioneringen installeras så
att den används på ett säkert och korrekt sätt.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство и
руководство по установке наружного прибора перед установкой кондиционера.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
°π∞ ∞À∆√¡ ¶√À ∫∞¡∂π ∆∏¡ ∂°∫∞∆∞™∆∞™∏
PARA O INSTALADOR
FÖR INSTALLATÖREN
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
∂ÏÏËÓÈο
Português
Svenska
Русский

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric SLZ-KA25

  • Page 1: Installation Manual

    Air-Conditioners SLZ- KA25, KA35, KA50VAQ KA25, KA35, KA50VAL INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, please read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie- nungsanleitung und das Installationshandbuch gründlich durchlesen.
  • Page 2: Table Of Contents

    • In a place as far away as possible from fluorescent and incandescent lights (so the infrared remote control can operate the air conditioner normally). 2.2. Wireless remote controller mounting (For SLZ-KA25/KA35/KA50VAL) • Place of mounting In rooms where inverter type fluorescent lamps are used, the signal from the •...
  • Page 3: Installation Diagram

    3. Installation diagram 3.1. Indoor unit (Fig. 3-1) (mm) A Ceiling B Grille C Obstacle D Min. 1000 mm E Min. 500 mm (Entire periphery) If setting the maintenance space for E, be sure to leave is a minimum of 700 mm. Warning: Mount the indoor unit on a ceiling strong enough to withstand the weight of the unit.
  • Page 4 4. Installing the indoor unit 4.3. Installation of duct (in case of fresh air intake) (mm) (Fig. 4-3) Caution: Linkage of duct fan and air conditioner ln case that a duct fan is used, be sure to make it linked with the air conditioner when outside air is taken.
  • Page 5: Refrigerant Piping Work

    B Outdoor unit Piping preparation ø6.35 • Refrigerant pipes of 3, 5, 7, 10 and 15 m are available as optional items. (1) Table below shows the specifications of pipes commercially available. SLZ-KA25, KA35: ø9.52 Outside diameter Min. wall Insulation Insulation SLZ-KA50: ø12.7...
  • Page 6: Drainage Piping Work

    5. Refrigerant piping work 5.4. Pipe connection (Fig. 5-8) Indoor unit 1) When using commercially available copper pipes: • Apply thin layer of refrigerant oil to pipe and joint seating surface before tightening flare nut. • Use two wrenches to tighten piping connections. •...
  • Page 7: Electrical Work

    G Wired remote controller terminal • Attach the electric component cover securely. If it is attached incorrectly, it B Electric component box (For SLZ-KA25/KA35/KA50VAQ) could result in a fire, electric shock due to dust, water, etc. C Entry for Indoor-Outdoor connecting cable H Indoor controller •...
  • Page 8: Remote Controller

    7. Electrical work • Perform wiring as shown in the diagram to the lower left. (Procure the cable locally). Indoor terminal block (Fig. 7-4) Make sure to use cables of the correct polarity only. Earth wire (green/yellow) 1 Connecting cable Cable 3-core 1.5 mm , in conformity with Design 245 IEC 57.
  • Page 9: Function Settings

    7. Electrical work 7.4. Function settings 7.4.1 Function setting on the unit (Selecting the unit functions) ⁄ Mode number 1) AUTO RESTART FUNCTION ⁄ Setting number Indoor controller board ⁄ Refrigerant address This model is equipped with the AUTO RESTART FUNCTION. ⁄...
  • Page 10: Installing The Grille

    8. Installing the grille 8.1. Check the grille accessories (Fig. 8-1) • The grille should be supplied with the following accessories. Accessory name Q’ty Remark 650 × 650 (mm) Grille M5 × 0.8 × 25 (mm) Screw with washer Gauge Fastener Band Fig.
  • Page 11 D Screw with washer (Accessory) E Grille F Bell shaped hole G Receiver (For SLZ-KA25/KA35/KA50VAL) 8.3.3. Securing the grille (Fig. 8-7) • Secure the grille to the main unit by tightening the previously installed two screws (with captive washer) as well as the two remaining screws (with captive washer).
  • Page 12: Test Run

    D Position of the levers on the intake grille when sent from the factory. * Although the clips can be installed in any of four positions. E Receiver (For SLZ-KA25/KA35/KA50VAL) 8.6. Check • Make sure that there is no gap between the unit and the grille, or between the grille and the surface of the ceiling.
  • Page 13 9. Test run 9.2.2. Wired remote controller (Fig. 9-2) A ON/OFF button 1 Turn on the power at least 12 hours before the test run. B Test run display 2 Press the [TEST] button twice. ➡ “TEST RUN” liquid crystal display C Indoor temperature liquid line tem- 3 Press the [Mode selection] button.
  • Page 14 9. Test run • Refer to the following tables for details on the check codes. [Output pattern A] Beeper sounds Beep Beep Beep Beep Beep Beep Beep OPERATION · · · Repeated INDICATOR lamp flash pattern Approx. 2.5 sec. 0.5 sec. 0.5 sec.
  • Page 15 C About 1000 cc F Emergency operation switch (cooling) 9.4.2. For wired remote controller SLP-2ALW (For SLZ-KA25/KA35/KA50VAL) (1) Remove the cover of the water supply inlet and add about 1000 cc of water using Fig. 9-5 a water supply pump etc. During this process, be careful not to spray water into the drain pump mechanism.
  • Page 16 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE.B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX, UB8 1QQ, U.K. Printed in Thailand...

Table of Contents