Page 1
P E R F O R M A N C E OUTDOOR UNIT INDOOR UNIT 4.36 RAS 4-6HVRNME AF RWH 4.0-6.0FS(V)NFE The Yutaki S80 high temperature heat pump is the ideal solution for replacing boilers. It suits all existing installations and provides heating and domestic hot water.
Domestic Heating Ideal solution for boiler replacement The YUTAKI S80 heat pump is able to produce hot water at 80°C WIRELESS THERMOSTAT with -20°C outdoor temperature (without supplementary power supply), it is thus ideal for the refurbishment market and adapts to all types of existing installation.
Operation with verylowoutside temperature! Easy installation YUTAKI S80 has standard dimensions (l x D: 595 x 695 mm) to easily integrate in all types of homes. When it is installed underneath the DHW module, YUTAKI S80 is in any case shorter than 2 m (mod. 195L). Plumbing connections with standard supplied flexible hoses, designed to reduce and aid the installer's...
Page 4
80°C DOMOTICA COMPATIBILE COMPA P P TIBILE BMS Control option via Konnex with New Hitachi Intelligent Adjustment. chi Intelligent A specific interface. Il controllo Intelligente Hitachi Jusqu'à -15°C extérieur One of the best COP on the market: 4.36 Power is maintained constant even at The choice of an Economical solution.
SCROLL 1. The nominal cooling and heating capacity represent the combined capacity of the Hitachi YUTAKI-S80 system and are based on the EN14511 Standard. (*): The test is performed based on flow obtained during the test of standard nominal conditions.
Page 6
Domestic Heating Yutaki S80 Application for domestic hot water production and heating with 1 circuit HITACHI HITACHI HITACHI Application for domestic hot water production and heating with 2 circuits HITACHI HITACHI HITACHI HITACHI Cascade Applica on Chau age Individuel Modular centralised application for heating Centralisé...
1272 x 595 x 600 1602 x 595 x 600 Storage Tank Dimensions if on top of 1940 x 595 x 600 2270 x 595 x 600 Yutaki S80 Module (H x L x l) Empty weight Colour RAL 9016 White Exchange coil surface m²...
Page 8
Operations performed by Hitachi TS: Checking Vacuum of refrigerant piping and opening Gas R410A Piping Cocks. Checking correct Hydraulic Circuiting of the YUTAKI-S80 system according to Hitachi specifications. Checking Correct wiring and checking safety device tripping. Checking correct water flow. Setting operation parameters based on design requirements.
Page 9
Domestic Heating YUTAKI-S80 Accessories BMS KONNEX Interface ON-OFF Thermostat With Konnex Interface, operation consisting of WIRELESS settings can be controlled also remotely. It is easily matched to the KNX protocol. ambient thermostat and radio receiver to control one Zone. CODE ATW-KNX-01 CODE ATW-RTU-01...