Steps to Update the E8212 zl Module Software
1.
Copy new software to primary or secondary flash memory on acitive
management module:
USB – E8200zl#copy usb flash K_13_60.swi pri
TFTP – E8200zl#copy tftp flash 192.168.248.10
k_13_60.swi pri
After downloading a new software version to either the primary or
secondary flash of the active management module, the software version
is immediately copied to the corresponding flash (primary or secondary)
of the standby module unless the standby module failed selftest or
redundancy was disabled with the no redundancy management-module
command.
2.
Make sure boot setting is configured to boot to correct flash to which the
software was copied.
E8200zl#boot set-default flash primary
E8200zl#write memory
This change will also be synchronized to standby management module.
3.
Boot standby module
E8200zl#boot standby
This does not interrupt current switch operations yet. After the standby
management module has rebooted and is back in standby mode. You can
verify this by using the showredundancy command.
Example during reboot.
ProCurve Switch 8212zl# show redundancy
Settings
--------
Mgmt Redundancy : Enabled
Statistics
----------
Failovers
Last Failover
: Tue May 12 17:30:07 2009
Slot Module Description
---- ---------------------------------------- --------
MM1
ProCurve J9092A Management Module
MM2
ProCurve J9092A Management Module E8200zl Active
Secondary
: 3
Status
SW Version Boot Image
E8200zl Unknown
HP Switch zl Modules
K.13.60
11