Summary of Contents for Nectre Fireplaces FS 800

  • Page 1 NECTRE FIREPLACES Installation & Operating Instructions FS 800 FS 500 IS 800 IS 500 Pecan Engineering Pty Ltd 13 Acorn Road DRY CREEK SA 5094 Ph. (08) 8349 8332 Fax. (08) 8260 6643 www.nectre.com email: info@pecan-eng.com.au Toll Free 1800 636 301...
  • Page 3: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS INSTALLATION INFORMATION MANTLEPIECE FLOOR PROTECTOR INSTALLATION/DIMENSIONS OF HEATERS DOOR HANDLE ADJUSTMENT DOOR GLASS DOOR GASKET FIREBRICKS LIGHTING YOUR FIRE INITIAL OPERATING PERIOD GENERAL OPERATION OVERNIGHT BURN BAFFLE PLATE LOCATION FAN SERVICE CLEANING THE FIREBOX CONTROLS WARRANTY REPLACEABLE COMPONENTS OF THE HEATER...
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS This heater must be installed to the specifications and clearances listed on the compliance plate to ensure your safety. Variances from these specifications will void your warranty and could cause a serious house fire. To ensure compliance with the relevant Australian Standards, your heater must be installed with the recommended flue system.
  • Page 5: Installation Information

    INSTALLATION INFORMATION A licensed accredited installer should install all wood heaters. Please ask retailer to locate an installer. All warranty is void unless installed by an authorised installer. MANTLEPIECE No heat sensitive material may be placed closer than 300mm to the sides and 600mm above the hot air outlet, without adequate heat shielding in terms on clause 3.4.2 AS/NZS 2918:2001 FLOOR PROTECTOR...
  • Page 6: Installation/Dimensions Of Heaters

    INSTALLATION OF PEDESTAL MODELS Your new wood heater installation must confirm to Australian Standards AS/NZS 2918:2001, and be clear of combustibles as shown below. Currently for installation with an Australian Standard Double Cased flue kit with a full-length half radius perforated mesh flue shield. OUTER CASING NO LESS THAN 25MM CLEARANCE STAINLESS STEEL...
  • Page 7 For pedestal models only CLEARANCES FOR PEDESTAL MODELS MODEL FLUE DIA. FS 500 1020 FS 800 1140 NOTE: Floor Protector requirements shown are a guide only, installation must meet or exceed the recommended minimum requirements listed in the table above. FLOOR PROTECTOR 12mm thick fibre cement sheet with thermal conductivity 0.41 W/m degree K...
  • Page 8: Door Handle Adjustment

    DOOR HANDLE ADJUSTMENT If leaking occurs the door gasket may be loose. It may be required to adjust the door handle. If this occurs: 1. Wait until heater is cool. 2. Open door. 3. Undo lock nut on handle shaft and remove. 4.
  • Page 9: Firebricks

    FIREBRICKS The firebricks are designed to fit in the base and along the rear and side walls of the firebox. Please ensure the bricks are fitted before using the fire. LIGHTING YOUR FIRE 1) Place firelighters and pieces of crumpled newspaper in firebox floor. 2) Cover the paper with small diameter split kindling.
  • Page 10: General Operation

    GENERAL OPERATION Once the heater has been burning on high for approximately 20 to 30 minutes it will have reached operating temperature. You may now slow the burn down by adjusting the air slide into the closed position. Turn the fan on to the preferred speed setting.
  • Page 11: Baffle Plate Location

    BAFFLE PLATE LOCATION BAFFLE PLATE To clean your flue system the baffle plate will need to be removed. Before continuing ensure the fire is completely extinguished. 1) Lift baffle up from the rear and slide forward out through the door. You will need to lift the rear lip of the baffle plate over the front and rear mounting rods.
  • Page 12: Fan Service

    FAN SERVICE To provide years of trouble free operation the fan motor bearings are factory lubricated. However, damage can occur if dust or lint builds up in blades. Therefore the fan assembly should be inspected and cleaned each year. 1. Turn off power and disconnect power lead. 2.
  • Page 13: Warranty

    TEN YEAR WARRANTY:- Pecan Engineering Pty Ltd warrants this stove to be able to operate under normal use and service and within ten years from the date of the original purchase on the terms herein shall repair or replace without cost to the original customer any part thereof which shall be returned to our factory, transportation charges prepaid and which our inspection shows would prevent operation.
  • Page 14: Replaceable Components Of The Heater

    REPLACEABLE COMPONENTS OF THE HEATER 1. Firebricks 800 Series 7 x 285mm x 175mm x 25mm 500 Series 6 x 235mm x 175mm x 25mm 1 x 235mm x 85mm x 25mm 2. Ash Deflector 800 Series 595mm x 115mm x 5mm 500 Series 495mm x 115mm x 5mm 3.