hit counter script

Lenovo THINKCENTRE 8084 Hardware Maintenance Manual page 77

Lenovo computer accessories user manual
Table of Contents

Advertisement

Diagnostic Error Code
018-196-XXX
PCI Card test halt, error threshold exceeded
018-197-XXX
PCI Card test warning
018-198-XXX
PCI Card test aborted
018-199-XXX
PCI Card test failed, cause unknown
018-250-XXX
PCI Card Services error
020-000-XXX
PCI Interface Test Passed
020-0XX-XXX
PCI Interface error
020-195-XXX
PCI Test aborted by user
020-196-XXX
PCI test halt, error threshold exceeded
020-197-XXX
PCI test warning
FRU/Action
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 55
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 55
2. Flash the system and re-test. See "Flash
update procedures" on page 214
3. Go to "Undetermined problems" on page
90
1. Go to "Undetermined problems" on page
90
2. Flash the system and re-test. See "Flash
update procedures" on page 214
3. Replace component under function test
1. PCI card
2. Riser card, if installed
3. System board
No action
1. PCI card
2. Riser card, if installed
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 55
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
Chapter 7. Symptom-to-FRU Index
71

Advertisement

Table of Contents
loading

Table of Contents