1. Precaution Follow these special safety precautions. Although the microwave oven is completely safe during ordinary use, repair work can be extremely hazardous due to possible exposure to microwave radiation, as well as potentially lethal high voltages and currents. 1-1 Safety precautions ( 1.
Page 3
Pretaution 1-2 Special Servicing Precautions (Continued) 16. When checking the continuity of the witches or transformer, always make sure that the power is OFF, and one of the lead wires is disconnected. 17. Components that are critical for safety are indicated in the circuit diagram by shading, 18.
2. Specifications 2-1 Table of Specifications MODEL AKM106 ITEM TIMER 99 MINUTES 99 SECONDS POWER SOURCE 120V/60HZ, AC POWER CONSUMPTION MICROWAVE : 1.4KW(IEC), 1.25KW(CNS) OUTPUT POWER FROM90W TO900W (10 LEVEL POWER ; IEC) (IEC-705 TEST PROCEDURE) OPERATING FREQUENCY 2,450MHz MAGNETRON...
4. Disassembly and Reassembly 4-1 Replacement of Magnetron, Motor Assembly and Lamp Remove the magnetron including the shield case, Cover Air permanent magnet, choke coils and capacitors (all of which are contained in one assembly). Thermo S/W BKT-T.C.O Lamp 1. Disconnect all lead wires from the magnetron and lamp.
Page 7
Disassembly and Reassembly 4-3 Replacement of Door Assembly 4-3-1 Removal of Door Assembly Remove screws securing the upper hinge and Upper Hinge lower hinge. Then remove the door assembly. Screw Lower Hinge Screw 4-3-2 Removal of Door "C" Insert flat screwdriver into the gap between Door Door "C"...
Page 8
Disassembly and Reassembly 4-3-5 Reassembly Test After replacement of the defective component parts of the door, reassemble it and follow the instructions below for proper installation and adjustment so as to prevent an excessive microwave leakage. 1. When mounting the door to the oven, be sure to adjust the door parallel to the bottom line of the oven face plate by moving the upper hinge and lower hinge in the direction necessary for proper alignment.
Page 9
Disassembly and Reassembly 4-6 Replacement of Control Circuit Board 4-6-1 Removal of Control Box Assembly 1. Be sure to ground any static electric charge in your body and never touch the control circuit. 2. Disconnect the connectors from the control Screw circuit board.
3. Before touching any oven components or wiring, always unplug the oven from its power source and discharge the high voltage capacitor. 5-1 High Voltage Transformer 1. Remove connectors from the transformer terminals Filament Terminals and check continuity. 2. Normal resistance readings are as follows: Primary MODEL AKM106 Terminals Secondary ¡ Filament Shows Continuity Primary 0.40W ¡...
Alignment and Adjustments 5-4 High Voltage Capacitor 1. Check continuity of the capacitor with the meter set at the highest resistance scale. 2. Once the capacitor is charged, a normal capacitor shows continuity for a short time, and then indicates 9MW. 3.
Page 12
Alignment and Adjustments 5-8 Output Power of Magnetron CAUTION MICROWAVE RADIATION PERSONNEL SHOULD NOT ALLOW EXPOSURE TO MICROWAVE RADIATION FROM MICROWAVE GENERATOR OR OTHER PARTS CONDUCTING MICROWAVE ENERGY. The output power of the magnetron can be measured by performing a water temperature rise test. Equipment needed : * Two 1-liter cylindrical borosilicate glass vessel (Outside diameter 190 mm) * One glass thermometer with mercury column...
Alignment and Adjustments 5-10 Procedure for Measurement of Microwave Energy Leakage 1) Pour 275±15cc of 20±5ûC(68±9ûF) water in a beaker which is graduated to 600cc, and place the beaker in the center of the oven. 2) Start to operate the oven and measure the leakage by using a microwave energy survey meter.
6. Troubleshooting PRECAUTION 1. CHECK GROUNDING BEFORE CHECKING FOR TROUBLE. 2. BE CAREFUL OF THE HIGH VOLTAGE CIRCUIT. 3. DISCHARGE THE HIGH VOLTAGE CAPACITOR. 4. WHEN CHECKING THE CONTINUITY OF THE SWITCHES OR TRANSFORMER, DISCONNECT ONE LEAD WIRE FROM THESE PARTS AND THEN CHECK CONTINUITY WITHOUT THE POWER SOURCE ON.
Page 15
Troubleshooting 6-1 Electrical Malfunction(continued) SYMPTOM CAUSE CORRECTIONS Oven lamp and fan motor turn on 1. Misadjustment or loose wiring Adjust door and latch switches. of primary latch switch 2. Defective primary latch switch Oven can program but timer 1. Open or loose wiring of secondary Adjust door and interlock switches.
Exploded Views and Parts List 7-3 Door Parts List Ref. No. Parts No. Description/Specification Q'ty Remarks DE67-20167A SCREEN-DOOR;ACRYL,T1.5,W238.6,L440,WHT,MW6 DE02-00125A TAPE-DOUBLE FACE;ACRYL,T0.45,W9,WHT,WF103,#4420 DOOR-A DE64-40276H DOOR-A;ABS(HR0370),-,-,-,-,AKM106,- DE92-50128E ASSY DOOR-E;COATING,WHT,MW6574W,-,-,-,- DE64-40010A DOOR-C;PP(TB53),T1.5,WHT,MW6574W,-,-, DE01-00004A FILM-DOOR;PE,T0.15,W189,L331,NTR,1.2CU.F DE64-40006B DOOR-KEY;POM(TC3005),T2,12GR,WHT,MW5574 DE61-70128A SPRING-KEY;HSW3,PI0.6,D5,BLUING,-,-,- DE61-80002A HINGE-UPPER;SCP1,T2.3,26,77,ZPC3,WHT,CE945 DE61-80003A HINGE-LOWER;SCP1,T2.3,26,77,ZPC3,WHT,CE945 7-4 Control Parts List Ref.
9. Schematic Diagrams 9-1 Schematic Diagrams WARNING POWER MUST BE DISCONNECTED BEFORE SERVICING THIS APPLINACE CAVITY PRIMARY S/W FUSE H. V. TRANSFORMER 250V20A 130V 120V 120V POWER CORD H. V. CAPACITOR AC 120V/60Hz MAGNETRON POWER RELAY (SECONDARY INTERLOCK) P.C.BOARD 1. INPUT : 120V 60HZ DOOR NOTE: CIRCUIT SHOWN WITH DOOR IS OPENED POSITION.