Notes:
1. Flip up 2 protection sheets for the doctor
blade from the sleeve before inserting the
gauge. Also, be sure not to damage the
protection sheets.
2. When confirming and adjusting the gap
between the developer sleeve and the
doctor blade, insert the gauges into the
gap after rotating the developer sleeve so
that its marking faces the doctor blade.
(5)
Insert the gauge "0.60" of the doctor-sleeve
jig into the gap between the developer
sleeve and the doctor blade and make sure
that the gauge can move smoothly in the
front/rear direction. In addition, confirm that
the gauge "0.70" cannot be inserted into the
gap.
© 2008 TOSHIBA TEC CORPORATION All rights reserved
Doctor-sleeve gap jig
Fig. 3-34
Fig. 3-35
Doctor-sleeve gap jig
Fig. 3-36
e-STUDIO2820C/2830C/3520C/3530C/4520C
3 - 73
Protection sheet
Doctor blade
Marking
ADJUSTMENT
3