hit counter script

Technical Characteristics And Dimensions; General Description; Explanation Of Model Code; Package Contents - Bosch HydroPower TF250-8G(10H) Installation Manual And Operating Instructions

Table of Contents

Advertisement

4 | Technical Characteristics and Dimensions

2
Technical Characteristics and Dimensions
2.1

General Description

Models
Bosch Hydropower TF250/325/400
Category
CONTINUOUS FLOW
Type
GAS - EXTERNAL INSTALLATION
Table 2
2.2

Explanation of Model Code

TF (Top Flue)
250 (10 litres/min
@ 25 °C Rise)
TF (Top Flue)
325 (13 litres/min
@ 25 °C Rise)
TF (Top Flue)
400 (16 litres/min
@ 25 °C Rise)
Table 3
2.3

Package contents

Gas hot water unit
Documentation
2.4

Product overview

HydroPower Ignition is exclusive to Bosch - it does not require
a 240V power supply.
HydroPower uses the energy created by the water flow to
ignite the burner and begin the heating process. The unit
only starts when a hot water tap is opened. Once the tap is
turned off, the unit turns off.
2.5

Description of the Hot Water Unit

Hot Water Unit for external wall-mounting only
Available in Natural gas or LP gas
Hydrogenerator produces sufficient energy to ignite and
control the heater
– Water enters the Hydrogenerator
– The turbine spins with water flow
– A voltage is generated by the turbine
– This voltage causes the ignition control unit to light a
temporary pilot
– The water pressure opens the main burner gas valve
and the pilot ignites the main burner, the pilot then
goes out
– The water flows through the heat exchanger where it is
heated
Safety devices:
8 716 473 071 (2015/04)
G (Hydrogenerator)
G (Hydrogenerator)
G (Hydrogenerator)
– Flame rod to check for accidental extinction of the
burner flame
– Overtemperature switch to prevent overheating.
Water filter on the inlet water supply
Economical
Only heating water when required, the Bosch range is
extremely economical to run.
Versatile
LPG models are particularly popular in country areas, where
Natural Gas is not available.
Low Temperature Areas
In areas where the atmospheric temperature may drop to 0 °C
for brief periods, the installation of an EXOGEL valve (part
number H707 060 151) will minimise the possibility of
damage to the appliance if the water freezes.
NOTICE:
This water heater MUST NOT be installed in
areas where the temperature remains below
0 °C for extended periods.
Fig. 1
EXOGEL valve
[1] Hot water
[2] Cold water
[3] EXOGEL valve
HydroPower

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hydropower tf325-8g(13h)Hydropower tf400-8g(16h)

Table of Contents