Sign In
Upload
Manuals
Brands
Lenovo Manuals
Network Hardware
ThinkAgile CP
Lenovo ThinkAgile CP Manuals
Manuals and User Guides for Lenovo ThinkAgile CP. We have
2
Lenovo ThinkAgile CP manuals available for free PDF download: Hardware Part Replacement And Component Maintenance Procedures, Part Replacement And Component Maintenance Procedures
Lenovo ThinkAgile CP Hardware Part Replacement And Component Maintenance Procedures (162 pages)
Brand:
Lenovo
| Category:
Network Hardware
| Size: 4.45 MB
Table of Contents
Table of Contents
3
Figures
5
Tables
7
Chapter 1. Thinkagile CP Overview
9
CP Interconnect
11
Thinkagile CP4000 Series Overview
12
Thinkagile CP6000 Series Overview
15
Management Switch
15
Interconnect
15
Thinkagile CP Solution Components
18
Storage Block Parts List
18
Storage Block Parts Listing
18
Storage Block Components
19
Compute Block Parts List
20
Compute Block Part Listing
20
Compute Block Components
21
Power Cords
22
Storage Block
22
Compute Block
22
Chapter 2. Roles and Responsibilities
23
System Board
24
Rack
26
Chapter 3. Installation Guidelines
27
System Reliability Guidelines
28
Working Inside the Solution with the Power on
28
Handling Static-Sensitive Devices
29
Chapter 4. Managing Support Mode
31
Enable Support Mode in the Cloud Controller
31
Cloud Controller Support Mode Menu
31
Access the Customer's System Via Support Mode
32
Turn on Support Mode Dialog Box
32
Port Number and Password for Support
32
Virtual Office Sign-In Page
32
Place a Support File on the Storage or Compute Node
34
Command to Connect to Customer's
34
Disable Support Mode in the Cloud Controller
36
Cloud Controller Support Mode Menu
36
Turn off Support Mode Dialog Box
36
Chapter 5. Part Replacement and Maintenance Procedures
37
Storage Block Maintenance Procedures
37
Storage Block Component Indicators
37
Enclosure Indicators
38
Drive Indicators
39
Storage Controller Indicators
40
Storage Controller Port Indicators
41
Shutting off a Storage Controller
42
Trigger Manual Storage HA
42
Shutting down the Storage Block
43
Replacing Storage Block Hardware
44
Replacing Storage Network Cables or Transceivers
44
Hot-Swap Drive Replacement
44
Hot-Swap Drive Removal
60
Hot-Swap Drive Removal
61
Namespace 1 Size: 794996768768 Bytes, 794.996768768 GB
63
Opening the Drive Tray Handle
64
Sliding the Drive into the Drive Bay
65
Namespace 1 Is Attached to Controller ID(S): 33
66
Nvme Control Device: /Dev/Nvme7
67
Slot: 4
67
Serial Number: S3HCNX0JC02195
67
Total Namespaces: 1
67
Namespace ID(S): 1
67
Namespace 1 Is Attached to Controller ID(S): 33
67
Hot-Swap Power Supply Replacement
70
Hot-Swap Power Supply Removal
72
Hot-Swap Power Supply Removal
73
Hot-Swap Power Supply Installation
76
Hot-Swap Power Supply Installation
77
Hot-Swap Storage Controller Replacement
78
Hot-Swap Storage Controller Removal
78
Hot-Swap Storage Controller Installation
79
SSH Sign-In to Proxy Server
83
Entering the Proxy Server Port
84
Entering the Proxy Server Password
84
Enclosure Replacement
86
Side Cover Removal
86
Screws Removal
87
Enclosure Removal from Rack
87
Removal of Side Cover
89
Installing the Enclosure into the Rack
90
Installing Screws on Front of Enclosure
90
Reinstalling the Side Cover
91
Complete the Parts Replacement
92
Compute Block Maintenance Procedures
93
Shutting off a Compute Node
93
Migrating Vms from a Compute Node
93
Migrate a VM between Compute Nodes
94
Replacing Compute Block Hardware
95
Hardware Replacement Procedures
95
Replace Compute Network Cables
95
Enable or Disable Maintenance Mode
96
Enable Maintenance Mode for a Node
96
Maintenance Mode Dialog Box
97
Disable Maintenance Mode for a Node
98
Hot-Swap Drive Replacement
99
Drive Removal
100
Drive Installation
101
Hot-Swap Power Supply Replacement
102
Hot-Swap Power Supply Removal
104
Fan Replacement
107
Hot-Swap Power Supply Installation
107
Fan Fault Leds
109
EIOM Replacement
115
EIOM Ports and Corresponding Node Number
115
EIOM Port Corresponding Node Number
115
EIOM Removal
116
EIOM Installation
117
DIMM Replacement
118
DIMM Removal
119
Location of the DIMM Connectors on the
121
DIMM Installation Sequence (Independent Mode/Normal Mode)
122
DIMM Installation Sequence (Mirror Mode/Lockstep Mode)
122
DIMM Installation Sequence (Mirror Mode/ Lockstep Mode for 3, 6, 9 and 12 Identical Dimms)
122
DIMM Installation Sequence (Sparing Mode)
122
Location of the DIMM Connectors on the
123
DIMM Installation
124
Compute Node Replacement
126
Replace the SD530 System Board
128
Replace the Compute Enclosure
128
Interconnect Switch Maintenance Procedures
129
Power off the Interconnect Switch in an SS-V3 Environment
129
Make the Secondary Interconnect Switch the Primary Interconnect
129
Recabling Management Switch from Primary
131
Recovering from DNS Misconfiguration
132
Interconnect Parts Replacement Procedures
134
Replace the Interconnect Switch
134
Removing the Interconnect from the
135
Cabling a Single-Interconnect Configuration
142
Hardware Management Network Connectivity
142
Single-Interconnect Configuration - Compute Node and Network Interconnect Connections
144
Single-Interconnect Configuration - Storage Block and Network Interconnect Connections
145
Cabling a Dual-Interconnect Configuration
146
Hardware Management Network Connectivity
146
Dual-Interconnect Configuration - Compute Node and Network Interconnect Connections
148
Dual-Interconnect Configuration - Storage Block and Network Interconnect Connections
149
Dual-Interconnect Configuration - Inter
149
Replacing a Cable between Two Interconnect Switches
150
Hardware Management Network Cable Replacement
150
Management Switch Maintenance Procedures (Optional)
151
Replacing the Management Switch (Optional)
151
Power-Cord Retention Clip Removal
152
Releasing Switch Unit from the Rack
153
Removing Mounting Brackets from
153
Item
154
Switch
154
Attaching Mounting Brackets to Switch
155
Securing Switch to Rack Posts
155
Installing Power Cord Retention Clip
156
Hardware Management Network Cable Replacement
157
Chapter 6. Licensing Considerations
159
Advertisement
Lenovo ThinkAgile CP Part Replacement And Component Maintenance Procedures (98 pages)
Brand:
Lenovo
| Category:
Network Storage Server
| Size: 2.73 MB
Table of Contents
Table of Contents
3
Figures
5
Chapter 1. Thinkagile CP Overview
7
Storage Block
8
Compute Block
8
CP Interconnect
9
Chapter 2. Roles and Responsibilities
11
Interconnect
13
Number
13
Switch
13
Chapter 3. Installation Guidelines
15
System Reliability Guidelines
16
Working Inside the Solution with the Power on
16
Handling Static-Sensitive Devices
17
Chapter 4. Managing Support Mode
19
Enable Support Mode in the Cloud Controller
19
Cloud Controller Support Mode Menu
19
Access the Customer's System Via Support Mode
20
Turn on Support Mode Dialog Box
20
Port Number and Password for Support
20
Virtual Office Sign-In Page
20
Place a Support File on the Storage or Compute Node
22
Command to Connect to Customer's
22
Disable Support Mode in the Cloud Controller
23
Cloud Controller Support Mode Menu
24
Turn off Support Mode Dialog Box
24
Chapter 5. Compute Block Maintenance Procedures
25
Compute Block Maintenance Procedures
25
Shutting off a Compute Node
25
Migrating Vms from a Compute Node
25
Migrate a VM between Compute Nodes
26
Compute Block Parts Replacement Procedures
26
Replace Compute Network Cables
26
Remove a Compute Node
26
Install a Compute Node
27
Replace the Compute Enclosure
28
Drive Replacement
28
Drive Removal
29
Drive Installation
30
Hot-Swap Power Supply Replacement
32
Hot-Swap Power Supply Removal
34
Fan Replacement
36
Hot-Swap Power Supply Installation
36
Fan Fault Leds
38
EIOM Replacement
42
EIOM Ports and Corresponding Node
42
EIOM Removal
43
EIOM Installation
44
DIMM Replacement
45
DIMM Removal
46
Location of the DIMM Connectors on the System Board
48
Location of the DIMM Connectors on the
50
DIMM Installation
51
Replace the SD530 System Board
52
Chapter 6. Storage Block Maintenance Procedures
53
Storage Block Maintenance Procedures
53
Storage Block Component Indicators
53
Enclosure Indicators
54
Drive Indicators
55
Storage Controller Indicators
56
Shutting off a Storage Controller
57
Storage Controller Port Indicators
57
Trigger Manual Storage HA
58
Shutting down the Storage Block
59
Storage Block Parts Replacement Procedures
59
Replacing Storage Network Cables or Transceivers
59
Remove a Storage Controller
59
Add a Storage Controller
60
Hot-Swap Drive Replacement
62
Hot-Swap Drive Removal
63
Opening the Drive Tray Handle
64
Sliding the Drive into the Drive Bay
65
Hot-Swap Power Supply Replacement
66
Hot-Swap Power Supply Removal
68
Hot-Swap Power Supply Removal
69
Hot-Swap Power Supply Installation
71
Hot-Swap Storage Controller Replacement
72
Hot-Swap Power Supply Installation
72
Hot-Swap Storage Controller Removal
73
Hot-Swap Storage Controller Installation
74
Replace the Storage Enclosure
75
Side Cover Removal
76
Screws Removal
77
Enclosure Removal from Rack
77
Removal of Side Cover
79
Installing the Enclosure into the Rack
80
Installing Screws on Front of Enclosure
80
Reinstalling the Side Cover
81
Chapter 7. Interconnect Switch Maintenance Procedures
83
Power off the Interconnect Switch in an SS-V3 Environment
83
Make the Secondary Interconnect Switch the Primary Interconnect
83
Recovering from DNS Misconfiguration
85
Recabling Management Switch from Primary
85
Chapter 8. Interconnect Parts Replacement Procedures
89
Replace the Interconnect Switch
89
Replacing a Cable between Two Interconnect Switches
89
Replace the Secondary Interconnect in a DS-V3 Configuration
89
Chapter 9. Management Switch Maintenance Procedures (Optional)
91
Hardware Management Network Cable Replacement
91
Replace the Management Switch
91
Management Switch
91
Power-Cord Retention Clip Removal
92
Releasing Switch Unit from the Rack
92
Removing Mounting Brackets from
92
Securing Switch to Rack Posts
93
Removing the Management Switch (Optional)
94
Installing Power Cord Retention Clip
94
Power-Cord Retention Clip Removal
95
Releasing Switch Unit from the Rack
96
Removing Mounting Brackets from
96
Advertisement
Related Products
Lenovo ThinkAgile HX Series
Lenovo ThinkAgile CP Series
Lenovo ThinkAgile MX Certified Node 2U
Lenovo ThinkAgile MX
Lenovo ThinkAgile HX
Lenovo THINKPAD DOCK II
Lenovo Think Centre 4503
Lenovo ThinkPad X13 Gen 4
Lenovo thinkpad 13
Lenovo ThinkServer 9158
Lenovo Categories
Laptop
Desktop
Server
Monitor
Tablet
More Lenovo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL