Sign In
Upload
Manuals
Brands
Miele Manuals
Dryer
T 980x
Miele T 980x Gas Dryer Repair Manuals
Manuals and User Guides for Miele T 980x Gas Dryer Repair. We have
1
Miele T 980x Gas Dryer Repair manual available for free PDF download: Technical Information
Miele T 980x Technical Information (67 pages)
Brand:
Miele
| Category:
Dryer
| Size: 1.01 MB
Table of Contents
Table of Contents
2
Warning and Safety Instructions
6
General Information
6
Gas Dryers
6
Fire Danger Due to Excessive Lint
7
Restoring the Ground Connection after Dismantling the Front and Side Panels
7
Modification History
8
C Technical Data
9
Table C-1: General Technical Data
9
Layout of Electrical Components
10
980X
10
Figure D-1: T 980X Component Layout
10
982X
11
Figure D-2: T 982X Component Layout
11
Casing, Front Panel
12
Technical Data
13
Service
13
Lid Removal
13
Figure 010-1: Lid Removal
13
Table 010-1: Casing Technical Data
13
Removing the Front Panel
14
Side Panel Removal
14
Figure 010-2: Front Panel Removal
14
Figure 010-3: Side Panel Removal
15
Door, Lock
16
Technical Data
17
Function
17
Door Lock (A2)
17
Service
17
Door Removal
17
Table 020-1: Door Technical Data
17
Door Hinge Removal
18
Installing the Door Hinge
18
Figure 020-1: Door Removal
18
Removing the Door Lock
19
Figure 020-2: Door Lock Removal
19
Drum, Rear Bearing, Residual Moisture Sensor, Heater Bank
20
Technical Data
21
Table 030-1: Drum Data
21
Table 030-2: Heater Data
21
Function
22
No-Load Detection
22
Residual Moisture Measurement
22
Table 030-3: Heater Bank and Drying Air NTC Resistance Values
22
Heater Control
23
Temperature Limiter with Manual Reset (1F1, 2F1, 3F1)
23
Drying Air NTC (1R30)
23
Heater Bank NTC (2R30)
23
Interior Drum Light (H3/6)
23
Fault Repair
23
Temperature Limiter with Manual Reset (F1) Has Tripped
23
Service
24
Heater Bank Removal (T 980X)
24
Rear Bearing Removal
25
Figure 030-1: Heater Bank Removal
25
Figure 030-2: Bearing Housing Attachment
26
Figure 030-3: Rear Bearing
26
Residual Moisture Sensor Removal
27
Drum Light Removal
27
Lightbulb Replacement
27
Gas Heating (T 982X)
28
Technical Data
29
Function
29
Gas Unit
29
Table 031-1: Gas Heating Data
29
Figure 031-1: Gas Ignition Schematic
30
Figure 031-2: Onset of Drying Process, before Gas Starts to Flow
30
Figure 031-3: Drying Process, after Gas Has Started to Flow
31
Figure 031-4: Drying Process, Flowing Gas Ignites the Flame
31
Figure 031-5: Drying Process after Flame Has Gone out
32
Service
33
Checking the Gas Burner
33
Figure 031-6: Port for Measuring Jet Pressure
34
Removing the Gas Solenoid
35
Figure 031-7: Gas Regulation Valve
35
Installing the Gas Solenoid Valve
36
Figure 031-8: Disconnecting the Gas Regulation Valve
36
Figure 031-9: Attaching the Gas Connecting Line to the Gas Regulation Valve
36
Figure 031-10: Tightening the Gas Regulation Valve
37
Figure 031-11: Gas Regulation Valve
37
Removing the Gas Burner
38
Figure 031-12: Gas Regulation Valve
38
Installing the Gas Burner
39
Figure 031-13: Gas Regulation Valve
39
Motor, Fan
40
Technical Data
41
Service
41
Fan Impeller Replacement
41
Table 040-1: Fan and Motor Data
41
Figure 040-1: Fan Impeller Removal
42
Motor Replacement
43
Air Shield, Front Bearing
44
Technical Data
45
Fault Repair
45
Vibration Noises from the Base Plate
45
Figure 050-1: Sealing Strip Installation
45
Table 050-1: Air Shield Data
45
Service
46
Air Shield Removal
46
Figure 050-2: Air Shield Removal
46
Felt Seal Replacement
47
Figure 050-3: Felt Seal Installation
47
Fascia Panel, Electronic
49
Technical Data
50
Function
50
Reversing (Electric) (T 980X)
50
Reversing (Gas) (T 982X)
50
Dryer Function after a Power Interruption
50
Programming Functions
50
Table 090-1: Technical Data
50
Residual Moisture Sensing
51
Table 090-2: Residual Moisture, Delicates
51
Overriding the Time Control
52
Insufficient Air Detection
52
Operating Hours Counter
52
Low-Voltage Detection
52
Table 090-3: Values for Low-Voltage Detection
52
Fault Repair
53
End" LED Is Steadily Lit
53
Check Filter/Vent" LED Is Steadily Lit
53
Check Filter/Vent" LED Flashes Rapidly
54
Rotary Iron" LED Flashes
54
Hand Iron" LED Flashes
54
All Program Leds Flash
55
F0: no Fault
55
F1: Short Circuit in Heater Bank NTC (2R30)
55
F2: Open Circuit in Heater Bank NTC (2R30)
55
F3: Drying Air NTC (1R30) Short Circuit
56
F4: Drying Air NTC (1R30) Open Circuit
57
F50: Motor Stalls and Heater Is on for 3 Seconds
57
F55: Overriding Time Limit Exceeded
57
F66: Air Leakage
58
F98: no Gas Ignition (T 982X Only)
58
Laundry Is Overdried/F55 (Overriding Time Limit Exceeded)
59
Dryer Shuts Itself off
59
Service
60
Programming Mode Summary
60
Table 090-4: Programming Mode Summary
61
Activating/Deactivating the Demonstration Mode
62
Service Mode Summary
62
Removing the Fascia, Electronic and Electronic Support Panel
64
Table 090-5: Service Mode Summary
64
Figure 090-1: Removing the Fascia, Electronic, and Electronic Support Panel
65
Electrical System
66
Technical Data
67
Service
67
Fuse Replacement (T 980X Only)
67
Heater Relay Removal
67
Figure 100-1: Fuse Replacement
67
Table 100-1: Electrical System Data
67
Advertisement
Advertisement
Related Products
Miele TOUCHTRONIC T 9802
Miele T 9800 VENT ED DRYER - OPERATING AND
MIELE Touchtronic T 9800
MIELE T 9802 VENT ED DRYER - OPERATING AND
Miele T 9800
Miele T 9802
Miele TOUCHTRONIC T 9820
Miele T 9822
Miele T 982x
Miele 09322300
Miele Categories
Washer
Dishwasher
Oven
Ventilation Hood
Dryer
More Miele Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL