Sign In
Upload
Manuals
Brands
Siemens Manuals
Controller
AVS75.390
Siemens AVS75.390 Manuals
Manuals and User Guides for Siemens AVS75.390. We have
3
Siemens AVS75.390 manuals available for free PDF download: User Manual
Siemens AVS75.390 User Manual (258 pages)
AVS75, AVS37, QAA75, QAA78, QAA55 Series Heat pump controller
Brand:
Siemens
| Category:
Controller
| Size: 5.44 MB
Table of Contents
Table of Contents
3
Ce1U2355En
2
Table of Contents
3
Overview
10
1.1 Product Range Overview
11
Topology
11
Operation Options
12
Safety Notes
13
Notes on Product Liability
13
Mounting Method
14
Engineering
14
Heat Pump Controller RVS
14
Regulations
14
Mounting and Installation
14
Dimensions and Drilling Plan
15
Connection Terminals RVS61.843
16
Terminal Markings:rvs41.813
16
Connection Terminals of RVS41.813
19
Terminal Markings RVS41.813
19
Extension Module AVS75.390
21
Dimensions and Drilling Plan
21
3.3.1 Connection Terminals AVS75.390
21
Terminal Markings
22
Assignment of Terminals
22
Operator Unit AVS37.294
23
Mounting Method
23
3.5 Operator Unit AVS37.390
24
Connections
24
Dimensions
24
3.6 Room Unit QAA55
25
Engineering
25
Dimensions and Drilling Plan
25
Room Unit QAA75
26
Engineering
26
Dimensions and Drilling Plan
27
RF Components
28
RF Module AVS71.390
28
Room Unit QAA78.610
29
Engineering
29
Mounting with the Base
29
Connections / Power Supply
30
Radio Connection
30
Dimensions and Drilling Plan
31
Wireless Outside Sensor AVS13.399
32
Mounting Method
32
Radio Connection
33
Dimensions and Drilling Plan
33
RF Repeater AVS14.390
34
Mounting Method
34
Connections
34
Radio Connection
34
Dimensions and Drilling Plan
34
Checking the RF Components
35
Commissioning
36
4.1 Heat Pump Controller
36
Handling
37
Qaa75
37
Operation
37
Operating Elements
37
Display Choices
38
Selecting Pace Heating Mode
38
Selecting DHW Heating Mode
39
Selecting Cooling Mode
39
Adjusting the Room Temperature Setpoint
40
Occupancy Button
40
Displaying Information
40
Manual Defrost of HP / Reset
42
Programming the QAA75
43
Setting Principle
43
Example "Setting the Time of Day
43
User Levels
44
Setting Structure "Heating Engineer
45
Setting Structure "End User
45
Overview of the Settings
46
Table of Contents
54
5.2 Qaa55
77
Display Choices
77
Operating Elements
77
Operation
77
Selecting Pace Heating Mode
77
Adjusting the Room Temperature Setpoint
78
Indication of Cooling Mode
78
Occupancy Button
78
Programming
79
Operation and Display
80
Operator Section
80
The Settings in Detail
80
Time of Day and Date
80
Heating Circuit Assignment
82
Room Sensor
82
Binding
83
Device Data
83
List of RF Devices
83
Radio Links
83
Holidays
84
Standard Program
84
Switching Points
84
Time Programs
84
Heating Circuits
85
Operating Mode
85
Setpoints
85
Heating Curve
86
ECO Functions
87
Flow Temperature Setpoint Limits
88
Room Influence
89
Boost Heating
90
Room Temperature Limitation
90
Optimum Start / Stop Control
91
Quick Setback
91
Overtemp Prot Pump Heating Circuit
92
Raising the Reduced Setpoint
92
Floor Curing Function
93
Mixing Valve Control
93
Buffer Storage Tank / Primary Controller
96
Excess Heat Draw
96
Cooling Circuit 1
97
Frost Protection for the Heating Circuit
97
Remote Control
97
Operating Mode
98
Release
98
Setpoints
98
Cooling Curve
99
Eco
99
Flow Temperature Setpoint Limits
100
Summer Compensation
100
Room Influence
101
Mixing Valve Control
102
Room Temperature Limitation
102
Dewpoint Monitoring
103
Buffer Storage Tank / Primary Controller
104
Remote Control
104
Domestic Hot Water
105
Frost Protection for the Heating Circuit
105
Overview
105
Setpoints
105
Release
106
Charging Priority
107
Legionella Function
107
Circulating Pump
109
Hx Pumps
109
Overview
109
Hx Pumps
110
6.10 Swimming Pool
111
Overview
111
Priority
111
Setpoints
111
6.11 Primary Controller / System Pump
112
6.12 Heat Pump
112
Overview
112
Plant Hydraulics
112
Function Diagrams
113
Condenser Pump
114
Source Pump
115
Compressor Control in Plants Without Buffer or Combi Storage Tank
116
Overview of Setpoint and Control Sensor Selection
117
Compressor Control in Plants with Buffer or Combi Storage Tank
118
Compressor Settings
119
Compressor 2
122
Electric Immersion Heater in the Flow
124
Heat Pump Protection During DHW Charging
126
General Parameters
127
Heat Pump Protection During DHW Charging
128
Defrost Function for Air-To-Water Heat Pumps
130
Automatic Defrost Function
131
Cooling
134
Frost Protection for the Heat Pump
134
During Compressor Operation
136
Sensor Calibration
137
Readj Hp Return Sensor
138
Readj Status
138
6.13 Energy Meter
139
Heat Volume Meter
141
Pulse Count Heat
141
Pulse Unit Heat
141
Pulse Unit Heat Denom
141
Pulse Unit Heat Numer
141
Flow Heating
142
Energy Counter Electricity/Natural Gas
143
Pulse Count Energy
143
Pulse Unit Energy
143
Pulse Value Energy Denom
143
Pulse Value Energy Numer
143
Counter/Performance Factor
144
Electric Source Output
144
Heat Delivered
144
Mean Gas Energy Content
144
Energy Brought in
145
Fixed Day Storage (Yearly Performance Factor)
145
6.14 Cascade
148
Control
148
Heat Source Sequence
148
Electric Immersion Heaters in the Cascade
149
Control
150
Operating Mode
150
Overtemperature Protection
150
Supplementary Source (Only RVS41
150
6.16 Solar
152
Charging Controller (Dt)
152
Overview
152
Priority
153
Collector Frost Protection
154
Overtemperature Protection for the Collector
154
Start Function
154
Medium's Evaporation Temperature
155
Speed Control
155
Yield Measurement
155
6.17 Buffer Storage Tank
156
Forced Charging
156
Overview
156
Automatic Locks
157
Overtemperature Protection
159
Stratification Protection
159
Electric Immersion Heater
160
Recooling
160
6.18 DHW Storage Tank
161
Abortion of DHW Charging
161
Charging Control
161
Solar Integration
161
Overtemperature Protection
162
Electric Immersion Heater
163
Recooling
163
Excess Heat Draw
164
Plant Hydraulics
165
Speed-Controlled Pump
165
Instantaneous DHW Heater (Only RVS61.843)
167
Overview
167
Transfer
167
6.20 Configuration
168
Mixing Valve Control
168
Procedure
168
Setpoints
168
Speed-Controlled Pump
168
Heating/Cooling Circuit 1
169
Manual Setting / Adjustment of Partial Diagrams
169
Preselection of Plant Diagram
169
Heating Circuit 2
170
DHW Controlling Element Q3
171
Separate DHW Circuit
171
Heat Pump
172
Solar
173
Buffer Storage Tank
174
Output Relay QX
174
Function Output QX4-Mod
179
Sensor Input BX1, BX2, BX3, BX4, BX5
179
Input H1, H3
180
Input EX1, EX2, EX3, EX4, EX5, EX6, EX7
186
Mixing Group
188
Extension Module
189
Frost Protection on the Extension Module
189
QX Extension Module
190
BX Extension Module
191
H2 Extension Module
191
10V Output UX
192
Building and Room Model
193
Types of Sensor / Readjustment
193
Air Dehumidifier
194
Frost Protection for the Plant
194
Parameters
195
Plant Diagram
195
Sensors
195
6.21 Lpb
198
Address / Power Supply
198
Device Data
198
Central Functions
199
6.22 Errors
201
Clock
201
Reset
201
Error History
202
Error List
202
Error Message Functions
202
6.23 Service / Special Operation
206
Maintenance Functions
206
Economy Mode
208
Other Maintenance Messages
208
Emergency Operation
209
Simulation
209
6.24 Input / Output Test
210
Definition of Responsibilities
210
Manual Defrost
210
Output Test Relays
210
Input Test Sensors
211
Output Test UX
211
Input Test E
212
6.25 State of Plant
213
Messages
213
6.27 Diagnostics Heat Source
217
Brine-To-Water Heat Pump
217
Diagnostics Cascade
217
History
217
Priority/State
217
Setpoints and Actual Values
218
Heat Pump Air
219
Time / Start Counter
219
Solar
220
6.28 Diagnostics Consumers
221
Outside Temperature
221
Room
221
Cooling Circuit 1
222
Heating Circuits 1, 2, P
222
Buffer Storage Tank
223
Common Flow
223
Domestic Hot Water
223
Primary Controller
223
Swimming Pool
223
Input H1
224
States Multifunctional Relays
224
States of Relays Extension Modules 1 and 2
224
Water Pressure
224
6.29 Pump Kick
225
Basic Diagrams
226
Plant Diagrams
226
Legend (Catalog of Plant Diagrams and Extra Functions)
241
Basic Units RVS61.843 and RVS41.813
242
Technical Data
242
Extension Module AVS75.390
243
Operator and Room Unit AVS37
244
RF Module AVS71.390
245
8.5 Wireless Outside Sensor AVS13.399
246
8.6 RF Repeater AVS14.390
247
8.7 Sensor Characteristics
248
8.7.1 NTC 1K
248
8.7.2 NTC 10K
249
Pt1000
249
Advertisement
Siemens AVS75.390 User Manual (221 pages)
Heat pump controller
Brand:
Siemens
| Category:
Controller
| Size: 3.2 MB
Table of Contents
Table of Contents
3
Summary
11
Product Range Overview
12
Topology
12
Operation Options
13
Safety Notes
14
Notes on Product Liability
14
Mounting and Installation
15
Regulations
15
Heat Pump Controller RVS61.843
15
Engineering
15
Mounting Method
15
Dimensions and Drilling Plan
16
Connection Terminals RVS61.843
16
Terminal Markings RVS61.843
17
Extension Module AVS75.390
19
Dimensions and Drilling Plan
19
Connection Terminals AVS75.390
19
Terminal Markings
20
Assignment of Terminals
20
Operator Unit AVS37.294
21
Mounting Method
21
Operator Unit AVS37.390
22
Connections
22
Dimensions
22
Room Unit QAA55
23
Engineering
23
Dimensions and Drilling Plan
23
Room Unit QAA75
24
Engineering
24
Dimensions and Drilling Plan
25
RF Components
26
RF Module AVS71.390
26
Room Unit QAA78.610
27
Engineering
27
Mounting with the Base
27
Connections / Power Supply
28
Radio Connection
28
Dimensions and Drilling Plan
29
Wireless Outside Sensor AVS13.399
30
Mounting Method
30
Radio Connection
31
Dimensions and Drilling Plan
31
RF Repeater AVS14.390
32
Mounting Method
32
Connections
32
Radio Link
32
Dimensions and Drilling Plan
33
Checking the RF Components
33
Commissioning
34
Heat Pump Controller RVS61.843
34
Handling
35
Qaa75
35
Operation
35
Operating Elements
35
Display Choices
36
Selecting Space Heating Mode
36
Selecting Cooling Mode
37
Selecting DHW Heating Mode
37
Adjusting the Room Temperature Setpoint
38
Occupancy Button
38
Displaying Information
38
Manual Defrost of HP / Reset
40
Programming the QAA75
41
Setting Principle
41
Example "Setting the Time of Day
41
User Levels
42
Setting Structure "Enduser
43
Setting Structure "Heating Engineer
43
Overview of the Settings
44
Qaa55
68
Operation
68
Operating Elements
68
Display Choices
68
Selecting Pace Heating Mode
68
Indication of Cooling Mode
69
Adjusting the Room Temperature Setpoint
69
Occupancy Button
69
Programming
70
The Settings in Detail
71
Time of Day and Date
71
Operator Section
71
Operation and Display
71
Heating Circuit Assignment
73
Room Sensor
73
Device Data
74
Radio Links
74
Binding
74
List of RF Devices
74
Time Programs
75
Switching Points
75
Standard Program
75
Holidays
75
Heating Circuits
76
Operating Mode
76
Setpoints
76
Heating Curve
77
ECO Functions
78
Flow Temperature Setpoint Limitations
79
Room Influence
80
Room Temperature Limitation
81
Boost Heating
81
Quick Setback
82
Optimum Start / Stop Control
83
Raising the Reduced Setpoint
83
Overtemp Prot Pump Circuit
84
Mixing Valve Control
84
Floor Curing Function
85
Excess Heat Draw
86
Buffer Storage Tank / Primary Controller
86
Remote Control
87
Frost Protection for the Heating Circuit
87
Cooling Circuit 1
87
Operating Mode
88
Setpoints
88
Release
88
Cooling Curve
89
Eco
89
Summer Compensation
89
Flow Temperature Setpoint Limitations
90
Room Influence
91
Room Temperature Limitation
92
Mixing Valve Control
92
Dewpoint Monitoring
93
Buffer Storage Tank / Primary Controller
94
Remote Control
94
Frost Protection for the Heating Circuit
95
Dhw
95
Summary
95
Setpoints
95
Release
96
Charging Priority
97
Legionella Function
97
Circulating Pump
98
Hx Pumps
98
Summary
98
Hx Pumps
99
Swimming Pool
100
Summary
100
Setpoints
100
Priority
100
Plant Hydraulics
101
Primary Controller / System Pump
101
Summary
101
Heat Pump
102
Function Diagrams
102
Condenser Pump
103
Source Pump
104
Compressor Control in Plants Without Buffer or Combi Storage Tank
105
Compressor Control in Plants with Buffer or Combi Storage Tank
106
Compressor Settings
107
Compressor 2
109
Electric Immersion Heater in the Flow
111
Heat Pump Protection During DHW Charging
113
General Parameters
114
Defrost Function for Air-To-Water HP
116
Automatic Defrost Function
117
Frost Protection for the Heat Pump
119
Cooling
119
Cascade
123
Control
123
Heat Source Sequence
123
Electric Immersion Heaters in the Cascade
124
Solar
125
Summary
125
Charging Controller Solar (Dt)
125
Priority
126
Start Function
127
Frost Protection for the Collector
127
Overtemperature Protection for the Collector
127
Medium's Evaporation Temperature
128
Speed Control
128
Yield Measurement
128
Buffer Storage Tank
129
Summary
129
Forced Charging
129
Automatic Locks
130
Stratification Protection
131
Overtemperature Protection
131
Recooling
132
Electric Immersion Heater
132
Solar Integration
133
DHW Storage Tank
133
Abortion of DHW Charging
133
Charging Control
133
Overtemperature Protection
134
Recooling
134
Electric Immersion Heater
135
Excess Heat Draw
136
Plant Hydraulics
136
Speed-Controlled Pump
137
Instantaneous DHW Heater
138
Summary
138
Setpoints
138
Speed-Controlled Pump
138
Mixing Valve Control
139
Configuration
139
Procedure
139
Preselection of Plant Diagram
139
Manual Setting / Adjustment of Partial Diagrams
139
Heating / Cooling Circuit 1
140
Heating Circuit 2
140
DHW Controlling Element Q3
141
Separate DHW Circuit
141
Heat Pump
142
Solar
143
Output Relay QX
144
Function Output QX4-Mod
148
Sensor Input BX1, BX2, BX3, BX4, BX5
148
Input H1, H3
149
Input EX1, EX2, EX3, EX4, EX5, EX6, EX7
154
Mixing Group
156
Extension Module
156
Frost Protection on the Extension Module
157
QX Extension Module
158
BX Extension Module
158
H2 Extension Module
159
Output UX
159
Types of Sensor / Readjustment
160
Building and Room Model
160
Frost Protection for the Plant
161
Air Dehumidifier
161
Sensors
162
Parameters
162
Plant Diagram
162
Device Data
165
LPB System
165
Address / Power Supply
165
Central Functions
166
Clock
167
Errors
168
Reset
168
Error Message Functions
168
Error History
168
Error List
169
Maintenance / Special Operation
173
Maintenance Functions
173
Other Maintenance Messages
175
Economy Mode
175
Emergency Operation
176
Simulation
176
Manual Defrost
177
Resetting Limitations
177
Definition of Responsibilities
177
Input / Output Test
177
Output Test Relays
177
Output Test UX / P1
178
Input Test Sensors
178
Input Test E
179
State of Plant
179
Messages
179
History
183
Diagnostics Cascade
183
Priority/State
183
Diagnostics Heat Source
183
Brine-To-Water Heat Pump
183
Setpoints and Actual Values
184
Time / Start Counter
185
Heat Pump Air
185
Solar
186
Diagnostics Consumers
187
Outside Temperature
187
Room
187
Heating Circuits 1, 2, P
187
Cooling Circuit 1
188
Dhw
188
Swimming Pool
189
Primary Controller
189
Common Flow
189
Buffer Storage Tank
189
Input H1
189
Water Pressure
189
States of Multifunctional Relays
190
States of Relays Extension Modules 1 and 2
190
Special Operating Codes
190
Plant Diagrams
191
Basic Diagrams
191
Plant Diagram 1
191
Plant Diagram 2
192
Plant Diagram 3
192
Plant Diagram 4
193
Plant Diagram 5
193
Plant Diagram 6
194
Plant Diagram 7
194
Plant Diagram 8
195
Plant Diagram 9
195
Plant Diagram 10
196
Plant Diagram 11
196
Plant Diagram 12
197
Plant Diagram 13
197
Plant Diagram 14
198
Plant Diagram 15
198
Plant Diagram 16
199
Plant Diagram 17
199
Plant Diagram 18
200
Plant Diagram 19
200
Plant Diagram 20
201
Plant Diagram 21
201
Plant Diagram 22
202
Plant Diagram 23
202
Plant Diagram 24
203
Heat / Refrigeration Source Variants / Extra Functions
204
Technical Data
205
Basic Unit RVS61.843
205
Extension Module AVS75.390
207
Operator and Room Unit AVS37
208
RF Module AVS71.390
209
Wireless Outside Sensor AVS13.399
210
RF Repeater AVS14.390
211
Sensor Characteristics
212
NTC 1 K
212
NTC 10K
213
Pt1000
213
Siemens AVS75.390 User Manual (239 pages)
Boiler controller
Brand:
Siemens
| Category:
Controller
| Size: 2.48 MB
Table of Contents
Table of Contents
3
1 Summary
5
Type Summary
6
Topology
6
The Communication Choices in Detail
7
2 Safety Notes
8
Notes on Product Liability
8
3 Mounting and Installation
8
Regulations
8
Basic Units RVS43.345
8
Connection Terminals RVS43.345
10
Extension Module AVS75.370
13
Connection Terminals AVS75.370
14
Extension Module Avs75.39X
16
Connection Terminals AVS75.390
17
Connection Terminals AVS75.391
19
4 Commissioning
21
Basic Unit RVS43.345
21
5 Overview of Settings
22
6 The Settings in Detail
51
Time Programs
51
Holidays
51
Heating Circuits
52
Cooling Circuit
70
Dhw
79
Consumer Circuits and Swimming Pool Circuit
84
Swimming Pool
86
Primary Controller/System Pump
88
Boiler
91
Cascade
103
Supplementary Source
108
Solar
113
6.13 Solid Fuel Boiler
120
Buffer Storage Tank
124
DHW Storage Tank
133
Instantaneous DHW Heater
146
Configuration
149
Lpb
183
Fault
187
Maintenance/Special Operation
188
Configuring the Extension Modules
192
Input/Output Test
197
State
198
6.24 Diagnostics Cascade
203
Diagnostics Heat Source
204
Diagnostics Consumers
205
Pump and Valve Kick
206
List of Displays
208
6.28.1 Error Codes
208
6.28.2 Maintenance Code
210
6.28.3 Special Operation Code
210
7 Plant Diagrams
211
Basic Diagrams
212
Basic Diagram RVS43.345
212
Source Variants
213
Extra Functions in General
214
Auxiliary Functions with Mixer Group or Extension Module AVS75.3XX
220
8 Technical Data
225
Basic Unit RVS43.345
225
Extension Module AVS75.370
227
Extension Module Avs75.39X
229
Sensor Characteristics
230
NTC 1 K
230
NTC 10 K
231
Pt1000
231
Index
232
Advertisement
Advertisement
Related Products
Siemens AVS71.390
Siemens AVS75 Series
Siemens AVS75.39 Series
Siemens AVS75.370
Siemens AVS75.391
Siemens AVS37.290
Siemens AVS37.294
Siemens AVS38.291
Siemens AVS13.399
Siemens AVS82.490
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL