Sign In
Upload
Manuals
Brands
Siemens Manuals
DC Drives
SINAMICS SM150 6SL3815-7NP41-0AA1
Siemens SINAMICS SM150 6SL3815-7NP41-0AA1 Manuals
Manuals and User Guides for Siemens SINAMICS SM150 6SL3815-7NP41-0AA1. We have
1
Siemens SINAMICS SM150 6SL3815-7NP41-0AA1 manual available for free PDF download: Operating Instructions & Installation Instructions
Siemens SINAMICS SM150 6SL3815-7NP41-0AA1 Operating Instructions & Installation Instructions (198 pages)
Medium-Voltage Drive
Brand:
Siemens
| Category:
DC Drives
| Size: 7.12 MB
Table of Contents
Table of Contents
5
1 Introduction
13
About These Instructions
13
2 Safety Instructions
15
Warning Symbol on the Device
15
Qualified Personnel
15
The 5 Safety Rules
15
Safe Handling
16
Electromagnetic Fields in Electrical Power Engineering Installations
19
Components that Can be Destroyed by Electrostatic Discharge (ESD)
19
Information for Nominated Persons in Control of an Electrical Installation
20
Proper Usage
20
Figure 2-1 ESD Information
20
Grounding Concept
22
Installation Site Safety
22
Measures for Operator Protection in Electromagnetic Fields
23
Residual Risks
23
Security Information
25
3 Description
27
Applications
27
Safety Concept
27
Safety Components and Functions
27
External Safety Components
28
Protection and Monitoring Functions of Internal Components
28
Protection and Monitoring Functions for External Components
29
Design
29
Components
29
Figure 3-1 Design of the Power Unit
30
Design of the Active Line Module and Motor Module
31
Operating Principle
31
Description of the Components
31
Figure 3-2 Active Line Module / Motor Module
31
SIMOTION Control Unit
32
Power Stack Adapter
33
Terminal Modules
34
Figure 3-3 Overview of PSA Interfaces
34
Voltage Sensing Module
35
SMC30 Sensor Module
35
Precharging
35
Electromechanical Door Interlock System
36
Make-Proof Grounding Switch
36
Circuit-Breaker (Provided by the Customer)
36
Converter Transformer
37
Actual Value Acquisition
37
Common Power Supply
38
Field of Application
38
Design
38
Figure 3-4 AVT Combination Module
38
Figure 3-5 Design When Using Igbts
38
Connections
39
Figure 3-6 Overview
39
DM10 Diagnostics Module
40
Functions
40
Figure 3-7 Schematic Diagram: Printed Circuit Board of the Diagnostics Module
40
Signal Processing
41
Figure 3-8 Logical Design of the DM10 Diagnosis Module
41
Voltage Monitoring
42
Re-Cooling Unit
43
Re-Cooling Unit Requirements
43
Operating Principle of the Re-Cooling Unit
43
The Internal Deionized Water Circuit
44
Customer Terminal Strips
44
Table 3-1 Deionized Water Requirements
44
Description of Options
45
NAMUR Terminal Strip (Option B00)
45
Auxiliary Voltage Supply 3 AC 200 V 50 Hz (Option C30)
45
Isolation Amplifiers for Optional Analog Inputs (Option E86)
46
Isolation Amplifiers for Optional Analog Outputs (Option E87)
46
Additional Terminal Module TM31 (Option G61)
46
Additional Terminal Module TM15 (Option G63)
47
PADU8 Diagnosis Module (Option G66)
47
Pulse Distributor for Splitting Speed Encoder Signal (Option G70)
48
Optical Bus Terminal (OBT) for PROFIBUS (Option G71)
48
Indicator Lamps in the Cabinet Door (Option K20)
48
Display Instruments in the Cabinet Door for Voltage, Current, Speed, and Output Plus Indicator Lamps (Option K21)
48
Safe Torque off
49
Safety Information Regarding the "Safe Torque off / Safe Standstill" Function
49
Description
51
Figure 3-9 "Safe Torque Off" Block Diagram
52
Figure 3-10 Connection Possibilities - Mushroom Pushbutton "Safe Torque off
53
Figure 3-11 Connection Possibility Button - "Acknowledge Safe Torque Off" or "Acknowledge
54
Figure 3-12 Function Overview Macro Interconnection
56
Start-Up
57
Figure 3-13 Safety Relay -K110 and Time Relay -K120
58
Figure 3-14 Voltage Monitoring Relay -A11
59
Cyclic Function Test
61
Acceptance Test and Log
61
Cyclic Function Test Log
62
Table 3-2 Example of the Cyclic Function Test Log
62
Acceptance Certificate
63
Circuit Overview
64
Output Reactor (Option L08)
67
DV/Dt Filter (Option L10)
67
Automatic Restart Function (Option L32)
68
Cabinet Illumination and Service Socket in Closed-Loop Control Unit (Option L50)
69
Disconnector at the Drive Output (Option L51)
69
Circuit Breaker at the Drive Output (Option L52)
69
Anti-Condensation Heating (Option L55)
70
EMERGENCY STOP Category 1 (Option L60)
70
Safety Locking System (Option M10)
71
Power Cable Connection at the Drive Input from above (Option M13)
71
Extended Dust Protection (Option M16)
71
Signal and Control Cable (Max. 2.5 MM²) (Option M32)
71
Suitability for Marine Use (Option M66)
71
Controlled Outgoing Circuit for Auxiliary Equipment 400 V 3 AC (Option N30)
72
4 Preparations for Use
73
Requirements for Installation Location
73
Inspections When Receiving the Delivery
73
Scope of Delivery
73
Checking Shock and Tilt Indicators
74
Checking the Load Handling Attachments
75
Transportation
76
Transport Markings
76
Transport Requirements
76
Observe Center of Gravity
77
Transport with a Fork-Lift Truck
77
Transport with a Crane
78
Using Lifting Rods
78
Transporting Transportation Units Packed in Boxes
80
Unpacking
81
Removing the Packaging
81
Removing Load Securing Devices
82
Lifting the Cabinet off the Transport Pallet
82
Opening Doors in Preparation for Use
83
Checking the Shock and Tilt Indicators Inside the Cabinet
84
Storage
84
Emptying the Drive
84
Storing a Device
85
5 Installation
87
Safety Instructions for Assembly
87
Tools Required
88
Removing Transport Rails
88
Screwing the Transport Units Together
88
Connecting to the Foundation
89
Connecting the Grounding Bars
90
5.7 Connecting the DC Bus
91
Preparation
91
5.7 Connecting the DC Bus
92
Connecting the Interface Terminals
93
Connecting the Water Circuits
93
Removing the Dust Protection Cover
94
Tools Required
94
Removing the Dust Protection Cover of the Closed-Loop Control Cabinet
94
Removing the Dust Protection Cover of the Inverter Cabinet
95
Removing the Dust Protection Cover of the Rectifier Cabinet
97
6 Electrical Connection
99
Safety Instructions for Electrical Connections
99
Electromagnetic Compatibility
101
Potential Concept
104
Electrical Requirements
105
Connection
105
Manually Unlocking Power-Unit Doors
105
Table 6-1 Dimensioning Cables
105
Table 6-2 Cable Cross-Sections
105
Connecting Ground
106
Preparations for Connecting the Power Cables
106
Connecting Power Cables
107
Connect the Power Cable to the Motor and the Supply System
107
Connect the Auxiliary Voltage
109
Table 6-3 Drive and Motor Connection Terminals
109
Connecting the Encoder
110
Connecting the Encoder to the SMC30 Sensor Module
111
Interconnecting Optional Connections
113
Connecting the Re-Cooling Unit to the Drive
113
Fastening the Cable Ducts with Cable Ties
113
7 Start-Up
115
8 Operation
117
Safety Instructions for Operation
117
Operating the Drive
118
Touch Screen Operator Panel
119
Parameter
120
Parameters
120
Parameter Types
120
Functions
121
Setpoint Channel and Closed-Loop Control
121
Setpoint Channel
121
Table 8-1 Parameter
122
Table 8-2 Parameter
122
Table 8-3 Parameter
122
Vector Control
124
U/F Control
127
Analog and Digital Inputs/Outputs
128
Analog Outputs
128
Additional Settings for Analog Outputs
130
Digital Inputs/Outputs
133
Digital Outputs
135
Monitoring Functions and Protective Functions
135
Insulation Monitoring
136
Tripping of the Circuit-Breaker in Case of Undervoltage
137
DC-Link Short-Circuiter
137
VDC-Max Closed-Loop Control
138
Fan Monitoring
140
Speed Monitoring with Incremental Encoder
140
Automatic Restart
140
Fault and System Messages
141
External Alarms and Faults
141
Message from the Grounding Switch
141
Diagnosis
143
Indicating and Rectifying Faults
143
Diagnostics Via Leds
143
Table 8-4 Leds of the Power Stack Adapters
143
Table 8-5 Leds of the DM10 Diagnostics Module
144
Diagnostics Via Parameters
145
9 Maintenance
149
Safety Instructions for Maintenance
149
Grounding the System
151
Grounding with a Grounding Device
151
Grounding Using a Make-Proof Grounding Switch
152
Opening the Doors
153
Opening the Power Unit Doors for Maintenance Work
153
Manually Unlocking Power Unit Doors
154
Secure Locking System (Option M10)
155
Inspection and Maintenance
156
Inspection
156
Checklist
156
Cleaning
157
Cleaning Aluminum Parts
158
Visual Inspections
158
Equipment for Visual Inspections
158
Checking Hoisting Solenoids and Security Bolts
158
Checking the Isolating Clearances
158
Checking the Capacitor Release
159
Checking the Cable and Screw Terminals
159
Checking the Plug Connections
159
Replacing the Filter Mats in the Roof Assembly
160
Maintaining the Fan
161
Repair
161
Torques
162
Table 9-1 Tightening Torque for Screws
162
Table 9-2 Tightening Torques for Screw Terminals for Copper Cables Without Cable Lug 1)
162
Replacing the AVT Combination Module
163
Replacing the Operator Panel
164
Replacing the Compactflash Card
165
Replacing the Powercard
166
Replacing the Power Stack Adapter
169
Replace the Sponge for the Leak Detector
170
Replacing Fuses
172
Replacing the Current Transformer
172
Door Interlock System
172
Replacing the Precharging Transformer
173
Replacing the Precharging Rectifier
174
10 Spare Parts
177
11 Disposal
179
Disposing of Packaging Material
179
Removing Device Components and Old Devices
179
Service & Support
181
Technical Data and Drawings
183
Technical Specifications
183
Standards and Regulations
183
Table B-1 Standards and Conformity
183
100 C Checklists and Forms
185
Checklists and Forms
185
Mechanical Installation: Checklist
185
Checklist for Electrical Installation
186
Index
191
Advertisement
Advertisement
Related Products
Siemens Sinamics SM150 6SL3845-2NN41-8AD0
Siemens SINAMICS SM150 6SL3810-7NN38-0AA1
Siemens SINAMICS SM150
Siemens SINAMICS G
Siemens Sinamics S120M
Siemens SINAMICS SL150
Siemens Simovert Masterdrives Compact Plus Series
Siemens SINAMICS SH150
Siemens SIMOVERT SC
Siemens SIMOVERT FC
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL