Sign In
Upload
Manuals
Brands
Siemens Manuals
Controller
SIRIUS 3RW51
Siemens SIRIUS 3RW51 Soft Starter Manuals
Manuals and User Guides for Siemens SIRIUS 3RW51 Soft Starter. We have
1
Siemens SIRIUS 3RW51 Soft Starter manual available for free PDF download: Equipment Manual
Siemens SIRIUS 3RW51 Equipment Manual (210 pages)
Soft starters and solid-state switching devices
Brand:
Siemens
| Category:
Controller
| Size: 13.35 MB
Table of Contents
Table of Contents
3
1 Siemens Industry Online Support
9
Siemens Industry Online Support App
10
Support Request
11
Additional Documentation
11
2 Safety Information
13
ESD Guidelines
13
Five Safety Rules for Working in or on Electrical Systems
14
Reactive Power Compensation
15
Electromagnetic Compatibility (EMC) According to IEC 60947-4-1
15
Security Information
16
Protection against Unauthorized Actuation
16
Firmware Update
16
Recycling and Disposal
16
3 Description
17
Target Group
17
Device Design
17
Operating Principle
18
Access Options for the 3RW51 Soft Starter
21
Operating Modes and Master Control Function
22
Device Versions
25
Areas of Application / Load Types
26
Selection of the Soft Starter Using the Simulation Tool for Soft Starters
27
Structure of the Article Number
28
Accessories
29
Communication Modules
29
3Rw5 Hmi
29
4 Mounting and Dismantling
33
Installing the 3RW51 Soft Starter
33
Mounting the Optional Fan Cover
33
Mounting the 3RW51 Soft Starter on a Level Surface
35
Mounting the External Bypass Contactor
36
Installing / Mounting / Removing 3RW5 HMI
37
Installing the 3RW5 HMI Standard in 3RW51 Soft Starter
37
Removing 3RW5 HMI Standard
38
Installing the 3RW5 HMI High Feature in the 3RW51 Soft Starter
39
Removing 3RW5 HMI High Feature
40
Installing the 3RW5 HMI Standard in the Control Cabinet Door
41
Installing the 3RW5 HMI High Feature in the Control Cabinet Door
45
Installing the 3RW5 HMI Standard on a Flat Surface
49
Installing the 3RW5 HMI High Feature on a Flat Surface
50
Cut out the Hinged Cover for 3RW5 HMI
52
Replacing the Hinged Cover of the 3RW51 Soft Starter
53
5 Wiring
55
Connections
55
Overview of All Connections
55
State Diagrams of the Inputs and Outputs
57
Connecting the 3RW51 Soft Starter
58
Connecting 3RW51 Soft Starter to Main Circuit Connection (Line Side / Motor Side)
59
Connecting the External Bypass Contactor to the 3RW51 Soft Starter
61
Replacing the Terminals on Size 1/2 Devices
62
Connecting the Control Terminals (Screw Terminals)
64
Disconnecting the Control Terminals from the Screw-Type Terminals
65
Replacing the Control Terminals
66
Installing the Cover for the Control Cable Duct (Optional Accessory)
67
Removing the Cover of the Control Cable Duct (Optional Accessory)
68
Removing the Protective Board
69
6 Parameter Assignment
71
Setting Elements on the 3RW51 Soft Starter
71
Overview of Parameters
73
Suggested Settings
74
Parameterizing the 3RW51 Soft Starter
74
Setting RESET MODE and Soft Torque
75
Reset Modes
77
Parameterizing Output 13 / 14 (Output Signal on or RUN)
78
Parameterize the Response to Bus Errors and Output
79
Analog Output
82
Parameterize 3RW5 HMI High Feature Serially / Identically
82
7 Commissioning
85
Commissioning the 3RW51 Soft Starter
85
Sealing the 3RW51 Soft Starter
85
First Commissioning of the 3RW5 HMI High Feature
86
8 Functions
89
Soft Starting
89
Current Limiting Function
92
Soft Stopping
94
Motor Protection
95
Electronic Motor Overload Protection
95
Intrinsic Device Protection
97
Soft Torque
97
Functions under "Additional Parameters
99
Test Mode
100
Test with Small Load
101
Response to Bus Errors / Control Via Digital Input
102
3RW5 HMI Standard
105
Design of the 3RW5 HMI Standard
105
3RW5 HMI Standard Menu
106
Setting Station Address Via 3RW5 HMI Standard
108
3RW5 HMI High Feature
109
Monitoring
109
Monitoring the Measured Values of the 3RW51 Soft Starter with the 3RW5 HMI High Feature
109
Graphic Display of Measured Values on the 3RW5 HMI High Feature
111
Monitoring the Process Image of the 3RW51 Soft Starter with the 3RW5 HMI High Feature
112
Overview
114
Design and Operator Controls of the 3RW5 HMI High Feature
116
Main Menu of the 3RW5 HMI High Feature with the 3RW51 Soft Starter
118
Parameterizing the 3RW5 HMI High Feature
121
Parameterizing Analog Output AQ Via the 3RW5 HMI High Feature
122
Defining the Local Access Protection (PIN)
124
Micro SD Card
125
9 Messages & Diagnostics
129
Diagnostics Options
129
LED Display
130
Overview of the Device Leds of the 3RW51 Soft Starter
130
Status and Error Displays
131
State / Overload Led
132
Overview of Leds on 3RW5 HMI Standard
132
Overview of Leds on 3RW5 HMI High Feature
133
Warnings and Remedial Actions of the 3RW51 Soft Starter
134
Faults and Remedial Actions of the 3RW51 Soft Starter
135
Faults and Remedial Actions on the 3RW5 HMI High Feature
139
Reset Modes
140
Diagnostics Via the 3RW5 HMI High Feature Module
141
Diagnostics of the 3RW51 Soft Starter with the 3RW5 HMI High Feature
141
Diagnostics of Communication with the 3RW5 HMI High Feature
145
Execute HMI Diagnostics with the 3RW5 HMI High Feature
145
Feature
146
Self-Test (User-Test)
146
Logbooks
149
Save Service Data to Micro SD Card
150
10 Maintenance and Servicing
153
Maintenance and Repairs
153
Firmware Update
153
Perform the Firmware Update Using Micro SD Memory Card (3RW5 HMI High Feature)
154
Restore Factory Setting
155
Restoring the Factory Settings Via 3RW5 HMI High Feature
156
Restoring the Factory Settings with the Master Reset Button Via 3RW5 HMI High Feature
157
Restoring the Factory Settings with the MODE and RESET / TEST Keys
158
Device Change" Function
158
Device Change with Micro SD Card on the 3RW5 HMI High Feature
159
11 Technical Specifications
161
Technical Data in Siemens Industry Online Support
161
12 Dimension Drawings
163
Cax Data
163
Drilling Pattern for 3RW5 HMI Standard
163
Drilling Pattern for 3RW5 HMI High Feature
164
13 Circuit Diagrams
165
Cax Data
165
Example Circuits
167
Main Circuit Connection
167
Feeder Assembly, Type of Coordination 1 Fuseless
167
Feeder Assembly, Type of Coordination 1 with Fuses
168
Feeder Assembly, Type of Coordination 2
169
Inside-Delta Circuit
169
Control Circuit Connection
173
Control by Pushbutton
173
Control by Switch
175
Switching with the Control Supply Voltage
177
Control by PLC
179
Actuation of a Line Contactor
181
Wiring for Remote RESET
184
Connecting the Evaluation Unit to the Analog Output
184
Serial Starting of 3 Motors with 3RW51 Soft Starter
185
Special Applications
187
Reversing Circuit
187
Controlling a Motor with a Magnetic Parking Brake
187
EMERGENCY STOP Shutdown to SIL 1 or PL C with a 3SK1 Safety Relay
189
Wiring of the 3SK1 Safety Relay SIL 1 with Line Contactor
192
Wiring of the 3SK1 Safety Relay SIL 1 Without Line Contactor
193
EMERGENCY STOP Shutdown to SIL 3 or PL E with a 3SK1 Safety Relay
193
Wiring of the 3SK1 Safety Relay SIL 3 with Line Contactor
197
Wiring of the 3SK1 Safety Relay SIL 3 with Line Contactor
198
Contactor for Emergency Start
198
Third-Party Software
203
Information about Third-Party Software
203
Glossary
207
Index
209
Advertisement
Advertisement
Related Products
Siemens SIRIUS Series
Siemens SIRIUS 3RT2.1-0CC0 Series
Siemens SIMOTION C
Siemens SIMATIC 500
Siemens Simatic S7 Series
Siemens SITOP UPS1600 under STEP 7 V12
Siemens SIMATIC PN/BACnet LINK
Siemens SIMATIC S7-1200 TCSB V3
Siemens SIMOTION P Series
Siemens SIMODRIVE 611 universal
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL