Sign In
Upload
Manuals
Brands
Siemens Manuals
Controller
Synco 700 Series
Siemens Synco 700 Series Manuals
Manuals and User Guides for Siemens Synco 700 Series. We have
3
Siemens Synco 700 Series manuals available for free PDF download: Basic Documentation, Manual
Siemens Synco 700 Series Basic Documentation (232 pages)
Modular boiler sequence controller including extension modules RMZ785, RMZ787, RMZ788 and RMZ789
Brand:
Siemens
| Category:
Controller
| Size: 2.58 MB
Table of Contents
Table of Contents
3
1 Summary
11
Product Range
11
System Topology
12
Equipment Combinations
12
Product Documentation
13
Important Notes
14
2 Operation
15
Operation Without Operator Unit
15
Operation with Operator Unit
16
Functions of the Operator Unit
16
Operating Concept
16
Operating Levels
17
Access Rights
18
3 Commissioning
19
Basic Concept
19
Entering the Commissioning Mode
22
Basic Configuration
22
Plant Types
22
Terminal Assignment and Properties of Outputs
31
Short Designations for Basic Module and Extension Modules
32
Maximum Configuration
32
Use of Configuration Diagrams
32
Extension Modules
34
Extra Configuration
36
Hydraulics-Dependent Inputs and Outputs of Function Block "Boiler Sequence Manager
37
Hydraulics-Dependent Inputs and Outputs of Function Block "Boiler
38
Hydraulics-Dependent Inputs and Outputs of Function Block "Precontrol
39
Hydraulics-Dependent Inputs and Outputs of Function Block "Heating Circuit
40
Miscellaneous
41
Faults
42
Configuration of the Universal Inputs and Outputs
42
Several Boiler Sequence Controllers RMK770
44
Wiring Test
45
Completing Commissioning
46
Data Backup
46
Device Information
46
Leaving the Password Level
47
Marking Changes
47
Plant Types and Default Terminal Assignments
48
4 General Settings
52
Time of Day and Date
52
Operating Principle
52
Communication
52
Fault Handling
53
Selecting the Language
54
Selecting the Unit of Temperature
54
Contrast of the Operator Unit's Display
54
Text Entry
54
Device Name and File Name
54
Aggregate Names
55
Text of Fault Inputs
55
Electronic Business Card
55
Resetting Text Entries
56
5 General Functions, Fundamentals
57
Time Switch
57
Communication
57
Entering the 24-Hour Program for Space Heating
58
Fault Handling
59
Holidays / Special Days
59
Communication
59
Holidays
60
Special Days
60
Calendar Entry
61
Control Inputs for Holidays and Special Days
61
Fault Handling
62
Frost Protection for the Plant
62
Pump Overrun and Mixing Valve Overrun
63
Pump Kick and Valve Kick
63
Heat Demand and Load Control
64
Heat Demand
64
Load Control
65
Mixing Valve Control
66
Control
66
Setting Aids
67
Control Signal
69
Pump Control
69
Hours Run Counter
69
Pump Supervision and Twin Pumps
70
Changeover Logic
71
Overload Message and Supervision of Flow
72
6 Boiler Sequence Management
73
Overview of Function Block
73
Configuration
74
Boiler Sequence Management
77
Concept
77
Orders for Boilers to be Switched on and off
78
Boiler Sequence Order
81
Boiler Sequence Operating Mode
83
Sustained Mode
85
Switching Boilers on and off
85
Supervision of Faults
89
Heat Demand and Heat Request
91
Heat Request Modulating
92
Heat Request 2-Position
92
Heat Demand Transformers
93
Other Functions
93
Common Maintained Boiler Return Temperature
93
Maximum Limitation of the Flow Temperature Setpoint
94
Frost Protection
95
Diagnostics
95
Fault Handling
97
7 Boiler Control
99
Overview of Function Block
99
Configuration
101
Burner Types
103
Boiler Hydraulics
104
Additional Boilers
106
Boiler Operating Modes and Boiler Setpoints
106
Releasing and Locking a Boiler
106
Individual Operation
107
Test Mode and Commissioning Aids
108
Control of the Burner
109
2-Position Control of 1-Stage Burners
109
2-Position Control of 2-Stage Burners
110
Control of Burner's Basic Stage and Stage 2
110
Control of Modulating Burners
112
External Burner Control
116
Protective Boiler Functions
116
Maximum Limitation of the Boiler Temperature
117
Minimum Limitation of the Boiler Temperature
117
Protective Boiler Startup
117
Optimization of the Minimum Boiler Temperature
118
Boiler Shutdown
118
Protection against Boiler Overtemperatures
119
Pump Kick and Valve Kick
119
Frost Protection for the Plant with Boiler Pump
119
Frost Protection for the Boiler
119
Protection against Pressure Shocks
120
Minimum Limitation of the Return Temperature
120
Flue Gas Temperature Supervision
122
Flue Gas Measuring Mode
123
Boiler Faults
124
Burner Hours Run Counter and Output Balance
126
Fault Status Messages
127
Boiler Designations
132
Diagnostic Choices
132
8 Heat Demand and Heat Requests
134
Heat Requests
134
Weather-Compensated Setpoint for Boiler Sequencing
135
Heat Demand Transformers
135
9 Precontrol
138
Overview of Function Block
138
Configuration
138
Types of Primary Controller
139
Control of Mixing Valve
139
Pump Control
139
Plant Operation
140
Heat Demand and Heat Request
140
Heat Request Modulating
141
Heat Request 2-Position
142
Heat Demand Transformers
142
Control of Mixing Valve
143
General
143
Load Control
143
Setpoint Boost Mixing Valve and System Pump
143
Limit and Protective Functions
144
Frost Protection
144
Limitations
144
Limitation of the Return Temperature
145
Pulse Limitation
146
Pump Overrun and Mixing Valve Overrun
147
Pump Kick and Valve Kick
147
Text Designation
147
Fault Handling
148
Diagnostic Choices
148
10 Heating Circuit Control
150
Overview of Function Block
150
Configuration
150
3-Position or Modulating Mixing Valve
152
Pump Control
152
Heating Circuit Operating Mode
152
Room Operating Modes
152
User Requests from the Room
154
Room Operating Mode Contact
154
Timer Function
155
Room Operating Mode Outputs
155
Plant Operation
157
Control Priorities in the Heating Circuit
157
Room Temperature Setpoints
159
Settings
159
Increasing the Economy Setpoint
160
Room Temperature Setpoint Adjuster, Absolute
160
Room Temperature Setpoint Adjuster, Relative
162
Weather-Compensated Heating Circuit Control
162
The Composite and the Attenuated Outside Temperature
163
Heating Curve
164
Influence on the Flow Temperature Setpoint
166
Heating Limit Switch
167
Mixing Valve Control
168
Control
168
Load Control
169
Optimization Functions
170
Type of Optimization
170
Otimum Start / Stop Control
171
Quick Setback and Boost Heating
171
Limit and Protective Functions
172
Maximum Limitation of the Room Temperature
172
Return Temperature Limitation
173
Pulse Limitation
175
Frost Functions and General Protective Functions
175
Pump Overrun and Mixing Valve Overrun
176
Pump Kick and Valve Kick
176
Heat Demand
176
Extra Functions
177
Text Designations
177
Acquisition of the Room Temperature
177
Room Control Combination
179
Fault Handling
181
Diagnostic Choices
182
11 Data Acquisition
184
Trend
184
Connections and Use
184
Views
184
Trend Function Settings
185
Fault Handling
186
Meters
186
Configuration
186
Meter Types
186
Pulse Valency
187
Overflow Value
188
Setting and Resetting Meter Readings
188
Meter Readings
188
Assignment of Texts
189
Fault Handling
189
12 Function Block "Miscellaneous
190
Overview of Function Block
190
Configuration
190
Outside Sensor
190
Outside Temperature Simulation
192
Fault Handling
192
Display Inputs
193
Outside Temperature Relay
194
Diagnostic Choices
194
13 Function Block "Faults
195
Overview of Function Block
195
Configuration
195
Fault Button
195
External Fault Button
196
Fault Properties
196
Acknowledgement and Reset
196
Signal Priority
197
Plant Behavior
197
State Diagrams of the Individual Types of Fault
198
Predefined Fault Inputs
199
Fault Inputs
199
Universal Fault Inputs
199
Analog Fault Input with Limit Value Supervision
201
Communication
202
Fault Relays
202
Display of Faults
204
Deletion of All Fault Status Messages
204
Function Check and Wiring Test
204
Diagnostic Choices
205
14 Communication
206
Basic Settings
206
Calendar Data (Holidays and Special Days)
207
Room Data
208
Communication Variants
208
Settings
208
Settings on the Room Unit
209
Heat Generation Zone and Boiler Sequence Zone
209
Heat Distribution Zones
210
Heat Demand and Load Control
211
Outside Temperature
211
Fault Handling
212
15 Fault Tracing Support
214
Fault Code List
214
Rectification of Faults
217
16 Addendum
218
Configuration Diagrams
218
Terminal Markings
218
Code Letters
218
Configuration Choices
218
Configuration Diagram Plant Type K
219
Configuration Diagram Plant Type K1.1
220
Editable Texts
221
Boiler Sequence Manager
221
Boilers
221
Primary Controller
222
Heating Circuit
222
Faults
223
Meters
223
Devices
223
Menu Tree
223
Info
224
Advertisement
Siemens Synco 700 Series Basic Documentation (120 pages)
Communication via the KNX bus
Brand:
Siemens
| Category:
Controller
| Size: 1.98 MB
Table of Contents
Table of Contents
3
1 KNX (Konnex) and Synco
7
General Overview
7
Definition of Terms
8
Synco 700, 900, RXB/RXL Range
10
Collective Terms for the Device Types
11
Product Markings on Synco Bus Devices
11
The KNX Network
12
Full-Scale KNX Network
12
Network Address
13
Device Address
14
Area/Line Couplers and IP Router
15
2 Engineering Notes
17
Designing the Network
17
Design Engineering Procedure
17
Number of Bus Devices Per Line, Area and Network
18
Bus Load Number E
18
Bus Power Supply
19
Decentral Bus Power Supply
19
Power Consumption of the Bus Devices
20
Central Bus Power Supply
21
Bus Topologies
22
Distances and Cable Lengths
23
3 Commissioning Notes
25
Points to Check Prior to Commissioning
25
Commissioning with the RMZ Operator Units
26
Starting Commissioning, Plant Mode "Off
26
Terminating Commissioning, Plant Mode "Auto
28
4 Device Address and Device Name
29
Reading the Area, Line and Device Address
29
Assigning Device Names
30
Setting Device Address with RMZ790 and RMZ791 Operator Units
32
5 Device Addresses Via ACS
33
Service Tool OCI700.1 and ACS7
33
Overview
33
New Plant
34
Establishing a Connection
35
Edit Device List
35
Addressing Devices with the OCI700.1 Service Tool
37
Assigning Addresses Manually
38
Assigning Addresses Automatically
39
Assigning Addresses in Programming Mode
40
Addressing Via the ID Number
41
Device Address for the Ozw771.XX Central Communication Units
42
Other Addressing Options, Ozw771.XX
43
Restoring the Factory Settings, Ozw771.XX
43
Device Address for the OZW775 Central Communication Unit
44
Device Address for the QAX910 Central Apartment Unit
45
Device Address for the RXB/RXL Room Controllers
48
RXB/RXL Device Address with QAX34.3 Room Unit
49
Device Address for the QAW740 Room Unit
51
Device Address for RMZ792 Bus Operator Unit
53
Addressing the Couplers
56
Line Couplers
56
Area Couplers
58
5.10 Addressing the IP Router
59
5.10.1 KNX Network Address
59
6 Basic Communication Settings
61
Decentral Bus Power
61
Clock Time Operation
61
Setting a Time Slave Remotely
62
Remote Reset of Fault
64
Basic Settings Via ACS
65
7 Communication Via Zone Addresses
67
General Notes on Zones
67
Synco Zoning
67
Communication of Process Values
68
Geographical Zone (Apartment)
69
Default
70
Zone Addressing with the RMZ Operator Units
72
QAWZ740 Room Unit
73
Addressing the Zones with ACS
74
RXB/RXL Room Controllers
75
Zone Addressing with the QAX34.3 Room Unit
75
8 Large Plants
77
Engineering and Commissioning
77
Network Topologies
78
IP Router as a Coupler to the IP Network
81
LTE Filter Table for Couplers and IP Routers
84
Filter Settings
84
Predefined LTE Filter Table
85
Filtering, Zone Addresses, Communication Areas
86
LTE Telegrams Via Couplers and IP Routers
87
System Time, Alarms and Remote Time Adjustments
89
Engineering of Large Plants
90
9 Appendix
93
Faults and Errors
93
Bus Fault Status Message
93
Communication Errors
94
Heating / Cooling Changeover
95
Changeover Via Digital Input
96
Changeover Via Analog Input
97
Changeover Based on Calendar
98
H/C Changeover Relay and Fault Messages
99
Room Control Combination
100
Application Examples
100
Applications with Zones
104
Additional Zones in the RXB/RXL Room Controller
105
Supply Chains
106
Data Exchange in LTE Mode
108
Updating the Process Values
109
Lightning and Overvoltage Protection, EMC
110
Lightning Protection
110
Overvoltage Protection
113
Overvoltages in Loops
114
EMC Protection Management
115
Siemens Synco 700 Series Manual (16 pages)
Switching and monitoring device
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 0.39 MB
Advertisement
Advertisement
Related Products
Siemens Synco700 RMK770
Siemens Synco 700
Siemens Synco 200
Siemens Synco RXB Series
Siemens Synco RXL Series
Siemens Acvatix SAS31.03
Siemens SIMOTION C
Siemens SQM50.264R1G4
Siemens SIMATIC WinAC Slot 416
Siemens SQM40.317A23
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL