Sign In
Upload
Manuals
Brands
YASKAWA Manuals
Servo Drives
SGDV DE5A Series
YASKAWA SGDV DE5A Series Manuals
Manuals and User Guides for YASKAWA SGDV DE5A Series. We have
1
YASKAWA SGDV DE5A Series manual available for free PDF download: User Manual
YASKAWA SGDV DE5A Series User Manual (311 pages)
AC Servo Drives; Linear Motor Command Option Attachable Type
Brand:
YASKAWA
| Category:
Servo Drives
| Size: 11.26 MB
Table of Contents
About this Manual
3
Safety Precautions
7
Warranty
13
Applicable Standards
15
Table of Contents
16
Chapter 1 Outline
22
Σ-V Series Servopacks
22
Part Names
22
SERVOPACK Ratings and Specifications
23
Ratings
23
Basic Specifications
25
SERVOPACK Internal Block Diagrams
28
Single-Phase 100-V, SGDV-R70FE5A, -R90FE5A, -2R1FE5A Models
28
Single-Phase 100-V, SGDV-2R8FE5A Model
28
Single-Phase 200-V, SGDV-120AE5A008000 Model
29
Three-Phase 200-V, SGDV-R70AE5A, -R90AE5A, -1R6AE5A Models
29
Three-Phase 200-V, SGDV-2R8AE5A Model
30
Three-Phase 200-V, SGDV-3R8AE5A, -5R5AE5A, -7R6AE5A Models
30
Three-Phase 200-V, SGDV-120AE5A Model
31
Three-Phase 200-V, SGDV-180AE5A, -200AE5A Models
31
Three-Phase 200-V, SGDV-330AE5A Model
32
Three-Phase 200-V, SGDV-550AE5A Model
32
Three-Phase 400-V, SGDV-1R9DE5A, -3R5DE5A, -5R4DE5A Models
33
Three-Phase 400-V, SGDV-8R4DE5A, -120DE5A Models
33
Three-Phase 400-V, SGDV-170DE5A Model
34
Three-Phase 400-V, SGDV-260DE5A Model
34
Examples of Servo System Configurations
35
Connecting to SGDV- FE5A SERVOPACK
35
Ae5A Servopack
36
Connecting to SGDV- DE5A SERVOPACK
38
SERVOPACK Model Designation
39
Inspection and Maintenance
40
Chapter 2 Panel Display and Operation of Digital Operator
42
Panel Display
42
Status Display
42
Alarm and Warning Display
42
Hard Wire Base Block Display
42
Displays During Overtravel
42
Utility Function Mode (Fn )
43
Parameter
44
Parameter Classifications
44
Parameter Notation
44
Parameter Setting Methods
45
Monitor Mode (un )
47
Chapter 3 Wiring and Connection
49
Main Circuit Wiring
49
Main Circuit Terminals
49
Using a Standard Power Supply Input (Single-Phase 100-V, Three-Phase 200-V, or Three-Phase 400-V)
50
General Precautions for Wiring
58
Using the SERVOPACK with Single-Phase, 200-V Power Input
59
Using the SERVOPACK with a DC Power Input
62
Using more than One SERVOPACK
64
I/O Signal Connections
65
I/O Signal (CN1) Names and Functions
65
Safety Function Signal (CN8) Names and Functions
66
Example of I/O Signal Connections
67
I/O Signal Allocations
68
Input Signal Allocations
68
Output Signal Allocation
70
Connection to Host Controller
71
Sequence Input Circuits
71
Sequence Output Circuits
73
Wiring Communications Using Command Option Modules
75
Linear Scale Connections
76
Linear Scale Signal (CN2) Names and Functions
76
Connection Example of a Linear Scale
76
Serial Converter Unit Specifications
78
Regenerative Resistors Connections
80
Connecting Regenerative Resistors
80
Setting Regenerative Resistor Capacity
82
Noise Control and Measures for Harmonic Suppression
83
Wiring for Noise Control
83
Precautions on Connecting Noise Filter
85
Connecting AC/DC Reactor for Harmonic Suppression
87
Chapter 4 Operation
90
Option Module Function Settings
90
Setting Switches S1 and S2 for Option Module Functions
90
Settings for Common Basic Functions
91
Inspection and Checking before Operation
91
Linear Servomotor Movement Direction
92
Overtravel
93
Electronic Gear
96
Encoder Output Pulse
99
Encoder Output Pulse Setting
101
Holding Brakes
102
Stopping Linear Servomotor after Receiving Servo off Command or Alarm Occurrence
106
Instantaneous Power Interruption Settings
108
Motor Maximum Speed
108
SEMI-F47 Function (Force Limit Function for Low Power Supply Voltage for Main Circuit)
109
Setting Motor Overload Detection Level
112
Test Without Motor Function
114
Related Parameters
114
Limitations
115
Digital Operator Display During Testing Without Motor
116
Limiting Force
117
Internal Force Limit
117
External Force Limit
118
Checking Output Force Limiting During Operation
119
Setting Absolute Linear Scale
120
Setup Procedure
120
Origin Setting (Fn020)
121
Polarity Detection (Fn080)
122
Absolute Linear Scale Reception Sequence
123
Other Output Signals
126
Servo Alarm Output Signal (ALM)
126
Warning Output Signal (/WARN)
126
Movement Detection Output Signal (/TGON)
127
Servo Ready Output Signal (/S-RDY)
127
Safety Function
128
Hard Wire Base Block (HWBB) Function
128
External Device Monitor (EDM1)
133
Application Example of Safety Functions
135
Confirming Safety Functions
136
Connecting a Safety Device
137
Precautions for Safety Functions
138
Chapter 5 Adjustments
141
Adjustments and Basic Adjustment Procedure
141
Adjustments
141
Basic Adjustment Procedure
142
Monitoring Analog Signals
143
Safety Precautions on Adjustment of Servo Gains
146
Tuning-Less Function
148
Tuning-Less Levels Setting (Fn200) Procedure
151
Advanced Autotuning (Fn201)
154
Advanced Autotuning
154
Advanced Autotuning Procedure
157
Related Parameters
162
Advanced Autotuning by Reference (Fn202)
163
Advanced Autotuning by Reference
163
Advanced Autotuning by Reference Procedure
165
Related Parameters
167
One-Parameter Tuning (Fn203)
170
One-Parameter Tuning
170
One-Parameter Tuning Procedure
171
One-Parameter Tuning Example
177
Related Parameters
178
Anti-Resonance Control Adjustment Function (Fn204)
179
Anti-Resonance Control Adjustment Function
179
Anti-Resonance Control Adjustment Function Operating Procedure
180
Related Parameters
184
Vibration Suppression Function (Fn205)
185
Vibration Suppression Function
185
Vibration Suppression Function Operating Procedure
186
Related Parameters
189
Additional Adjustment Function
190
Switching Gain Settings
190
Friction Compensation
196
Current Control Mode Selection
197
Current Gain Level Setting
197
Speed Detection Method Selection
197
Compatible Adjustment Function
198
Feedforward Reference
198
Using the Mode Switch (P/PI Switching)
198
Force Reference Filter
203
Position Integral Time Constant
205
Chapter 6 Utility Functions (Fn )
207
List of Utility Functions
207
Alarm History Display (Fn000)
208
JOG Operation (Fn002)
209
Origin Search (Fn003)
211
Program JOG Operation (Fn004)
213
Initializing Parameter Settings (Fn005)
219
Clearing Alarm History (Fn006)
220
Offset Adjustment of Analog Monitor Output (Fn00C)
221
Gain Adjustment of Analog Monitor Output (Fn00D)
223
Automatic Offset-Signal Adjustment of the Motor Current Detection
225
Automatic Offset-Signal Adjustment of the Motor Current
225
Detection (Fn00F)
226
Manual Offset-Signal Adjustment of the Motor Current
226
Fn00E
227
Fn00F
227
Write Prohibited Setting (Fn010)
227
Servomotor Model Display (Fn011)
229
Software Version Display (Fn012)
230
Resetting Configuration Error of Option Module (Fn014)
231
Vibration Detection Level Initialization (Fn01B)
232
Display of SERVOPACK and Servomotor ID (Fn01E)
234
Software Reset (Fn030)
235
Easyfft (Fn206)
236
Online Vibration Monitor (Fn207)
241
Chapter 7 Monitor Modes (un )
243
List of Monitor Modes
244
Monitor Displays
245
Chapter 8 Troubleshooting
246
Troubleshooting
246
List of Alarms
247
Troubleshooting
247
Troubleshooting of Alarms
251
Warning Displays
268
List of Warnings
268
Troubleshooting of Warnings
270
Troubleshooting Malfunction Based on Operation and Conditions of the Linear Servomotor
274
Chapter 9 Appendix
280
List of Parameters
280
Utility Functions
280
Parameters
281
Monitor Modes
301
Parameter Recording Table
302
Index
307
Revision History
310
Advertisement
Advertisement
Related Products
YASKAWA DR2
Yaskawa D Series
YASKAWA JUSP-MD D01A Series
YASKAWA SGDV-***A**A Series
YASKAWA SGDV-***F**A Series
YASKAWA SGDV-***D**A Series
YASKAWA SGDV-J Series
YASKAWA SGDV FE5A Series
YASKAWA SGDV AE5A Series
YASKAWA SGDV-01 FT001 Series
YASKAWA Categories
Controller
DC Drives
Servo Drives
Robotics
Inverter
More YASKAWA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL