9.15.2 Panel PCB ASSY

(1) Release the hooks to remove the panel PCB ASSY from the panel unit.
(2) Reverse the panel PCB ASSY. Release the locks to disconnect the LCD flat cable from
the panel PCB ASSY.
Panel PCB ASSY
Lock
LCD flat cable
Lock
Hook
Hooks
Panel unit
Fig. 3-57