hit counter script

Brother DCP-7080 Service Manual page 76

Hide thumbs Also See for DCP-7080:
Table of Contents

Advertisement

 Error code 6101
No Toner
Open the Front Cover, then install Toner Cartridge.
The new toner sensor detected that the toner cartridge was not set.
<User Check>
• Set the toner cartridge correctly.
• Replace the toner cartridge with a new one.
Step
New toner actuator coming off
1
Connection failure of the new
2
toner sensor PCB flat cable
New toner sensor PCB failure
3
Main PCB failure
4
 Error code 6801
Cooling Down
Wait for a while
The side thermistor of the fuser unit or the internal temperature sensor detected a
temperature higher than the specified value.
<User Check>
• Lower the room temperature.
• Keep the machine away from heating appliances.
Step
Side thermistor failure
1
Main PCB failure
2
Cause
Reattach the new toner actuator.
Reconnect the new toner sensor PCB flat
cable.
Replace the new toner sensor PCB ASSY.
Replace the main PCB ASSY.
Cause
Replace the fuser unit.
Replace the main PCB ASSY.
2-41
Remedy
Remedy