VIP X1 XF Table of Contents | en Table of Contents About this Quick Installation Guide Parts included Unpacking Installation Preparing for wall-mounting Mounting the frame Placing the unit in the frame Connection Connecting the camera and audio Creating a serial connection...
You should always make yourself familiar with the required safety measures (see Safety document enclosed). Only operate the VIP X1 XF in combination with an LPS/NEC Class 2 power supply unit with limited output. This Quick Installation Guide only describes the basic procedure for installing a VIP X1 XF and cannot replace the complete manual.
Unpacking – Check that the delivery is complete and in perfect condition. – Arrange for the unit to be checked by Bosch Security Systems if you find any damage. Bosch Sicherheitssysteme GmbH Quick Installation Guide F.01U.269.739 | V3 | 2014.03...
VIP X1 XF Installation Preparing for wall-mounting You can secure the VIP X1 XF to any load-bearing wall using the wall-mounting panel, in either a vertical or a horizontal position. CAUTION! If mounting the unit in a vertical position, you will need to use the lower plastic frame and then place the unit onto the frame from above.
VIP X1 XF Installation | en Mounting the frame CAUTION! The mounting location must be able to reliably hold the unit. The load-bearing capacity must be adequate for four times the weight of the unit. – Lift the plastic frame on one side of the housing and carefully remove it from the unit.
| Installation VIP X1 XF Placing the unit in the frame – Place the unit on the wall-mounting panel, with the panel positioned between the housing and the second plastic frame. – Slide the unit into the plastic frame until you feel it lock securely into place.
VIP X1 XF Connection | en Connection Connecting the camera and audio CAUTION! Please observe the following specifications: Line In: 9 kOhm typ., 5.5 Vp-p max. Line Out: 16 Ohm min., 3 Vp-p max. – Connect the camera to the socket VIDEO IN.
Please observe the labeling on the orange socket of the VIP X1 XF and the correct position for the terminal block. – If you require a serial connection to the VIP X1 XF, connect the relevant cables to the terminal block. –...
Alarm and relay connections CAUTION! Please observe the labeling on the orange socket of the VIP X1 XF and the correct position for the terminal block. Please observe the following specifications for the relay contacts: max. 30 V (SELV), 200 mA –...
| Connection VIP X1 XF Establishing the network connection – Connect the VIP X1 XF to the network via the ETH socket. F.01U.269.739 | V3 | 2014.03 Quick Installation Guide Bosch Sicherheitssysteme GmbH...
Connection | en Connecting the power supply CAUTION! Only operate the VIP X1 XF in combination with an LPS/NEC Class 2 power supply unit that has limited output and meets the following specifications: 9 to 30 V output voltage, 0.65 A max.
| Assigning an IP address VIP X1 XF Assigning an IP address NOTICE! Before you can operate the unit within your network, it must have a valid IP address for your network and a compatible subnet mask. – If you have not already done so, install the Video Client program from the product CD.