hit counter script

Electrical System Maintenance; Servicing The Battery; Storing The Battery; Checking The Fuses - Toro 30381N Operator's Manual

Traction unit
Table of Contents

Advertisement

Electrical System
Maintenance
Important: Whenever working with the electrical
system, always disconnect the battery cables, negative
(-) cable first, to prevent possible wiring damage from
short-outs.

Servicing the Battery

Service Interval: Every 50 hours—Check battery cable
connections.
WARNING
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead compounds,
chemicals known to the State of California
to cause cancer and reproductive harm.
Wash hands after handling.
Keep the top of the battery clean. If you store the machine in
a location where temperatures are extremely high, the battery
will run down more rapidly than if the machine is stored in
a location where temperatures are cool.
Keep the top of the battery clean by washing it periodically
with a brush dipped in ammonia or bicarbonate of soda
solution. Flush the top surface with water after cleaning it.
Do not remove the fill caps while cleaning the battery.
The battery cables must be tight on the terminals to provide
good electrical contact.
If corrosion occurs at the terminals, disconnect the cables,
negative (-) cable first, and scrape the clamps and terminals
separately. Reconnect the cables, positive (+) cable first, and
coat the terminals with petroleum jelly.
WARNING
Battery terminals or metal tools could short against
metal machine components causing sparks. Sparks
can cause the battery gasses to explode, resulting
in personal injury.
• When removing or installing the battery, do not
allow the battery terminals to touch any metal
parts of the machine.
• Do not allow metal tools to short between
the battery terminals and metal parts of the
machine.
WARNING
Incorrect battery cable routing could damage the
machine and cables causing sparks. Sparks can
cause the battery gasses to explode, resulting in
personal injury.
• Always disconnect the negative (black) battery
cable before disconnecting the positive (red)
cable.
• Always connect the positive (red) battery cable
before connecting the negative (black) cable.

Storing the Battery

If the machine will be stored more than 30 days, remove the
battery and charge it fully. Either store it on a shelf or on
the machine. Leave the cables disconnected if it is stored on
the machine. Store the battery in a cool atmosphere to avoid
quick deterioration of the charge in the battery. To prevent
the battery from freezing, make sure it is fully charged. The
specific gravity of a fully charged battery is 1.265-1.299.

Checking the Fuses

The machine fuses are located under the control panel.
Access them through the side panel cover (Figure 65). To
open the side panel cover, release the 2 latches and pull out
on it.
1. Side panel cover
37
Figure 65
2. Latches

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 7210

Table of Contents