8. Release CRT anode lead from CRT chassis wire clamp and all other wires from holders.
9. Loosen a screw that secures the DY and remove it from the CRT neck.
Caution:
To insure protection against x-ray radiation, the lens must be mounted in place at all times when power is applied to the PTV
CRT replacement
1. Remove CRT focus lens assembly (4 screws)
2. Lay CRT face down on a soft cloth.
3. Note position of yoke with centering tabs and remove from defective CRT.
4. Remove CRT DAG ground from defective CRT. Mount it on the replacement CRT exactly as it was on the defective CRT.
Note:
Replacement CRT is supplied with H.V. anode lead attached.
5. Wire the anode lead wire.
6. Install yoke with other CRT neck assemblies on CRT neck in the same order and position as removed from the defective CRT.
7. Press yoke against bell of CRT and tighten the clamp just snug enough so it will not easily shift.
8. Assemble CRT focus lens assembly to new CRT with (4) screws. Make sure focus lens adjustment nut is in the same
location as on other CRT focus lens
http://tsn.pstc.panasonic.com/viewing/NA/PT-53X54J/SVC/s1302000000.html (2 of 3) [23/04/2012 12:16:16 p.m.]
CRT assembly
CRT screw tightening order