User guide IM/MM-BK1 Rev. K MagMaster Electromagnetic flowmeters BOOK 1 Hazardous area approved flowmeters...
Page 2
Cert. No. Q 05907 applications. EN 29001 (ISO 9001) As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support.
Considerations ...... 7 2.2.4 Potting ........7 2.2.5 General ........8 2.2.6 MagMaster Sensor Temperature Limits ....8 Warning. • EXPLOSION HAZARD. SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS Ι, DIVISION 2. • EXPLOSION HAZARD. DO NOT REMOVE FUSE OR DISCONNECT POWER LEADS WHILE CIRCUIT IS LIVE.
• The ultimate responsibility for the safety of any installation lies with the installing user/contractor. 1.1 Introduction The range of hazardous area approved MagMaster Flowmeters available are listed in Table 1.1. Identification and their use is shown on a certification label, found on the side of the Sensor Termination Box.
Sensor and the Transmitter must only be that The approval is valid for the following countries: supplied for the purpose by ABB. Other types of cable may not be substituted, even for part runs. Austria, Belgium, Denmark, Finland, France,...
…1 CENELEC/ATEX APPROVED FLOWMETERS ...1.4 Installation 1.5 Safety of Pressurised Flowlines – The approval permits If the flowmeter is to operate at significantly more Environmental Protection installation below ground level where provision has than one bar, see the following EECS Newsletter been made to prevent flooding.
Page 7
1 CENELEC/ATEX APPROVED FLOWMETERS... EXTRACT FROM EECS NEWSLETTER We have discussed this recommendation with the NUMBER 15 (OCTOBER 1991) BASEEFA Advisory Council who have agreed that, if satisfactory measures to prevent the occurrence of voids cannot be taken, we should advise Certification of intrinsically safe apparatus for use applicants of the limitations of certification of at non-atmospheric pressure.
Transmitter must only be that supplied for the Identification and use is shown on certification purpose by ABB. Other types of cable may not be labels – on the side of the terminal box on remote substituted, even for part runs. Where joints between cables have to be made (e.g.
Local and National requirements may also preclude some of the above methods. 2.2.6 MagMaster Sensor Temperature Limits Table 2.1 Temperature Limits Standard temperature versions – Maximum process and ambient temperatures in °C. Std.