hit counter script

Sanyo C4272R S/C Installation Instructions Manual page 35

Sanyo split system heat pump air conditioner installation instructions
Table of Contents

Advertisement

07-115 SSHP_II
5/7/07
3:59 PM
KH(S)3072R, KH(S)3672R
One hole is required for the air conditioner tubing, and
may be either on the left or right side. (Also see section
3-14. Preparing the Indoor Side Tubing.)
(1) Tape the full-scale installation diagram on the wall
at the location selected. Make sure the unit is
horizontal using a level or tape measure to
measure down from the ceiling. (Fig. 3-25)
(2) Determine if the hole is to be drilled at the left or
right hole location.
(3) Before drilling a hole, check that there are no
studs or pipes behind the determined location.
CAUTION
(4) Using a sabre saw, key hole saw or 3-5/32 in.
hole-cutting drill attachment, make a hole in the
wall. The required minimum hole diameter for
these models is 3-3/16 in. (Fig. 3-26)
(5) Measure the thickness of the wall from the inside
edge to the outside edge and cut PVC pipe at a
slight angle 1/4 in. shorter than the thickness of
the wall. (Fig. 3-27)
(6) Place the plastic cover over the end of the pipe,
(for indoor side only) and insert in the wall.
(Fig. 3-28)
Page 35
Avoid any area where electrical
wiring or conduit is located.
Also take this precaution if the
tubing goes through a wall at
any other location.
Full-scale
installation diagram
Fig. 3-25
NOTE
Hole should be made at a slight downward slant to
the outdoor side.
Indoor
side
Fig. 3-26
PVC pipe (locally purchased)
Fig. 3-27
INSIDE
Plastic
cover
Fig. 3-28
35
Tape
Outdoor
side
Cut at slight angle
OUTSIDE
Wall
PVC pipe
Slight
angle
K