hit counter script
IBM Slicestor 2212A Appliance Manual
IBM Slicestor 2212A Appliance Manual

IBM Slicestor 2212A Appliance Manual

Cloud object storage system
Hide thumbs Also See for Slicestor 2212A:
Table of Contents

Advertisement

IBM Cloud Object Storage System
Version 3.14.1
Slicestor 2212A Appliance Manual
3401-S10/3403-S10
IBM

Advertisement

Table of Contents
loading

Summary of Contents for IBM Slicestor 2212A

  • Page 1 IBM Cloud Object Storage System Version 3.14.1 Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 2 Before using this information and the product it supports, read the following information: v The general information in Notices v The information in Safety and environmental notices v The information in the IBM Environmental Notices and User Guide (provided on a DVD) ™ This edition applies to IBM Cloud Object Storage System and is valid until replaced by new editions.
  • Page 3: Table Of Contents

    Notices ....31 requirements ... . 3 Trademarks . . 33 Appliance specifications Homologation statement . . 33 Requirements . System diagram . © Copyright IBM Corp. 2016, 2018...
  • Page 4 IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 5: Figures

    Push chassis into rack . . 11 Removing a PSU from the chassis . . 20 Rear of appliance . 11 Remove the battery . . 21 Front of appliance . . 12 Install the battery . 21 © Copyright IBM Corp. 2016, 2018...
  • Page 6 IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 7: Tables

    Power supply LED states . . 15 General specifications (Slicestor 2212A) Conditions indicated by drive carrier LEDs Power measurements for Slicestor 2212A 32GB Descriptions for the ports represented by this RAM w/ 4tb drives (FC:AJ0Y) . . 27 appliance .
  • Page 8 IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 9: Document Information

    Document information Intended purpose and audience ® This manual contains the instructions for installing and maintaining the Slicestor 2212A appliance. The audience for this guide consists of those individuals responsible for installing IBM Cloud Object Storage ™ System appliances. Note: v The equipment and device described for installation herein are sophisticated and relatively complex to install.
  • Page 10 IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 11: Safety And Environmental Notices

    Suitability for telecommunication environment - This product is not intended to connect directly or indirectly by any means whatsoever to interfaces of public telecommunications networks. Examples of a caution and a danger notice. Numbers in parentheses refer to message numbers in the IBM Safety Notices publication G229-9054, which is included with your product.
  • Page 12 If IBM supplied a power cord(s) , connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product. • Do not open or service any power supply assembly.
  • Page 13 DANGER: Professional movers are to be used for all relocation activities. Serious injury or death may occur if systems are handled and moved incorrectly. (D008) DANGER: Serious injury or death can occur if loaded lift tool falls over or if a heavy load falls off the lift tool.
  • Page 14: Environmental Notices

    Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. (L003) Environmental notices This information contains all of the environmental notices for IBM Systems products in English and other languages. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 15: Class A Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 16 20 A per phase. This statement explains the JEITA statement for products greater than 20 A, single phase. This statement explains the JEITA statement for products greater than 20 A per phase, three-phase. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 17 Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures. IBM Taiwan Contact Information: Electromagnetic Interference (EMI) Statement - Korea xvii...
  • Page 18 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 19: Declared Noise Emissions (1, 2, 3)

    Note: Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. This IBM system is available with an optional acoustical door feature that can help reduce the noise emitted from this system.
  • Page 20 IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 21: Support Information

    Support information For more information on the product or help with troubleshooting, contact IBM Support at IBMCloudStorageSupport@us.ibm.com or visit the Directory of worldwide contacts. © Copyright IBM Corp. 2016, 2018...
  • Page 22 IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 23: Chapter 1. Appliance Safety Precautions

    Be aware of the locations of the power switch on the appliance and the room’s emergency power-off switch, disconnection switch, or electrical outlet. If an electrical accident occurs, quickly remove power from the system. © Copyright IBM Corp. 2016, 2018...
  • Page 24: Electronic Components

    Remove any jewelry or metal objects from your body. They are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 25: Chapter 2. Specifications And Requirements

    Type and Usage Power Cords Use only the power cords that are supplied with the appliance. Do not use another type of cord. Do not use extension cords. If extra power cords are needed, contact IBM Support. Optical Fiber Cables Use IBM authorized enhanced small form-factor pluggable (QSFP and SFP+) transceivers only.
  • Page 26: System Diagram

    Figure 1. System diagram Figure 2. Drive layout IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 27: Chapter 3. Install The Appliance Into A Rack

    A reliable ground must be maintained always. To ensure grounding, the rack itself must be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit, such as the use of power strips. © Copyright IBM Corp. 2016, 2018...
  • Page 28: Appliance Installation

    The middle rail allows the outer rail to extend or shorten to accommodate racks of different depths. v The inner rail mounts on the side of the appliance and slides into the outer rail that is mounted on the rack, if wanted. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 29: Identifying The Sections Of The Rack Rails

    Figure 3. Identifying the sections of the rack rails Release the inner rail Remove the inner rail from each rail kit, as shown in the following figure. Figure 4. Remove the inner rails from both rail kits 1. Pull on the front release tab to unlock the inner rail from the rail kit. 2.
  • Page 30: Attaching The Sections Of The Rack Inner Rails

    3. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack. 4. Align the front tabs of the outer rail with the holes in the rack post, as shown in the following figure. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 31: Aligning The Outer Rails With Holes In Rack Post

    Figure 7. Aligning the outer rails with holes in rack post 5. Push the outer rail into the rack post so that the tabs go through the rack post and hold the rail in place, as shown in the following figure. Figure 8.
  • Page 32: Final Outer Rail Assembly And Mounting

    You might have to depress the locking tabs when inserting. When the appliance is pushed completely into the rack, you can hear the locking tabs click into the locked position. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 33: Rear Of Appliance

    Figure 11. Push chassis into rack 3. Secure the chassis to the rails with the captive M6 thumbscrews on the server. Cable the appliance 1. On the rear panel, connect the C13 end of the power cables to the C14 inlets in the PSU, as shown in the following figure.
  • Page 34 Figure 13. Front of appliance IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 35: Chapter 4. Appliance Physical Interface

    Power button/LED Disk drive 8 Non-maskable interrupt Disk drive 9 (NMI) button USB 2.0 ports (2) Disk drive 10 Individual disk activity Disk drive 11 LED (green) Individual disk status LED Disk drive 12 (blue/amber) © Copyright IBM Corp. 2016, 2018...
  • Page 36: Rear Panel

    PCIe card slot (on riser 10/100 Mbit/s management card) port PCIe card slot (on riser DB-15 video connector card) Disk controller card slot USB 2.0 ports (2) Unpopulated PCIe slot IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 37: Lan Led Connection Speed Indicator

    Network interface ports The LAN ports have two LEDs. One LED indicates activity when flashing. The other LED can be green, amber or off to indicate the speed of the connection, as shown in the following figure. See the following table for the functions that are associated with the connection speed LED.
  • Page 38: Descriptions For The Ports Represented By This

    1600 x 1200 at 75 Hz. USB 2.0 The USB ports can connect a USB keyboard or the supplied USB memory key to any of these connectors. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 39: Chapter 5. Field Replaceable Or Upgrade Units

    Chapter 5. Field replaceable or upgrade units A number of components can be replaced or upgraded in the field. Replacement parts Contact IBM Support for replacement parts for the appliance. The following customer serviceable parts are available: v Power supply module...
  • Page 40: Removing A Drive From The Chassis

    4. Press the release button on the drive carrier. This action extends the carrier handle, as shown in the following figure. Figure 19. Extending the handle for a drive from the chassis 5. Pull the drive carrier out of the chassis by using the handle. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 41: Removing A Drive From The Chassis

    Linux OS, a VGA-capable monitor, and a USB keyboard. CAUTION: The following procedure destroys any existing data on the USB flash drive. 1. Download the installation ISOs from IBM. 2. Insert the USB flash drive into the computer. 3. Determine the name of this drive.
  • Page 42: Replace External Rear Components

    5. Insert the module into the network card until it clicks into place. 6. Insert the fiber optic cable into the SFP+ / QSFP module. 7. Restart system and configure the network interface. For more information, see the Appliance Configuration Guide. IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 43: Battery Removal And Installation

    Handle used batteries carefully. Do not damage the battery in any way; a damaged battery can release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Refer to the IBM Systems Environmental Notices for battery disposal guidelines. Battery installation To install an Onboard battery, follow these steps: 1.
  • Page 44 IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 45: Appendix. Technical Specifications

    Table 11. Power measurements for Slicestor 2584 w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) 0.17 0.12 START 1200 0.95 1200 0.94 FULL 1700 0.98 1400 0.97 Table 12. Power measurements for Slicestor 2584 w/ 6tb drives (FC:AJ0Z) 100v 240v Power(W) Power(W) © Copyright IBM Corp. 2016, 2018...
  • Page 46: Power Measurements For Slicestor 2584 W/ 8Tb Drives (Fc:aj10)

    Voltage Range 200-240 V AC, FREQUENCY 50-60 Hz 2 hot-swappable 1100W PSUs in 1+1 configuration Table 16. Power measurements for Slicestor 3448 w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 47: Power Measurements For Slicestor 3448 W/ 6Tb Drives (Fc:aj0Z)

    Table 16. Power measurements for Slicestor 3448 w/ 4tb drives (FC:AJ0Y) (continued) 100v 240v 0.28 0.38 0.96 0.94 START FULL 1050 0.99 1050 0.98 Table 17. Power measurements for Slicestor 3448 w/ 6tb drives (FC:AJ0Z) 100v 240v Power(W) Power(W) 0.28 0.38 START 0.96...
  • Page 48: Power Measurements For Slicestor 2448 W/ 4Tb Drives (Fc:aj0Y)

    -40 to 65 degrees °C (-40-158 °F) Operating humidity 10-80% Non - operating humidity 5-90% Dimensions without front bezel (W x D x H) 17.250 x 26.125 x 3.4375 (in) 43.815 x 66.3575 x 8.73125 (cm) IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 49: Power Measurements For Slicestor 2212A 32Gb Ram W/ 4Tb Drives (Fc:aj0Y)

    Power cord C14/C13 (connector) 2 m (length) Input power options Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 26. Power measurements for Slicestor 2212A 32GB RAM w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) 0.27...
  • Page 50: Power Measurements For Slicestor 2212A 128Gb Ram W/ 4Tb Drives (Fc:aj0Y)

    Table 30. Power measurements for Slicestor 2212A 128GB RAM w/ 4tb drives (FC:AJ0Y) 100v 240v Power(W) Power(W) 0.27 0.85 START 0.99 0.95 FULL 0.99 0.92 Table 31. Power measurements for Slicestor 2212A 128GB RAM w/ 6tb drives (FC:AJ0Z) 100v 240v...
  • Page 51: Power Measurements For Manager 3105

    Table 34. General specifications (Manager 3105) (continued) M3105 Specification Rail/extended 27.5/34.5 (in) 69.85/87.63 (cm) Power cord C14/C13 (connector) 2 m (length) Input power options Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 35. Power measurements for Manager 3105 100v 240v Power(W)
  • Page 52: Power Measurements For Accesser 4105

    Voltage Range 100-240 V AC, FREQUENCY 50-60hz 2 hot-swappable 750W PSUs in 1+1 configuration Table 39. Power measurements for Accesser 4105 100v 240v Power(W) Power(W) 0.85 0.26 START 0.92 0.99 0.94 FULL IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 53: Notices

    This information was developed for products and services offered in the US. This material might be available from IBM in other languages. However, you may be required to own a copy of the product or product version in that language in order to access it.
  • Page 54 Statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only. All IBM prices shown are IBM's suggested retail prices, are current and are subject to change without notice. Dealer prices may vary.
  • Page 55: Trademarks

    International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
  • Page 56 IBM Cloud Object Storage System: Slicestor 2212A Appliance Manual 3401-S10/3403-S10...
  • Page 58 IBM® Printed in USA...

Table of Contents