Configuring the SIMATIC Box PC 620
Local Bus IDE
adapter
Large Disk
Access Mode
Memory Gap at
15 MByte
Submenu COM/LPT Configuration
Figure 5-10
The resources used by an interface are released when you disable the interface in
question.
The I/O addresses and interrupts are preassigned to be operated as COM1,
COM2 and LPT1 and we recommend you use them accordingly.
5-16
[Primary]
[Secondary]
[Both]
[Disabled]
[DOS]
[OTHER]
[Disabled]
[Enabled]
PhoenixBIOS Setup Utility
Advanced
COM/LPT Configuration
Internal COM 1:
Base I/O address:
Interrupt:
Internal COM2:
Base I/O address:
Interrupt:
Internal LPT1:
Mode:
Base I/O address:
Interrupt:
F1
Help
Select Item
ESC
Exit
Select Menu
"COM/LPT Configuration" Submenu
Primary IDE interface for max. two drives is
activated.
Secondary IDE interface for max. two drives is
activated.
Both IDE interfaces for max. four drives are
activated.
No local IDE interface is activated.
The drive tables are adapted for DOS access
operations in accordance with Enhanced IDE.
The tables are not adapted.
The complete onboard RAM memory is available.
A 1MB area of the RAM above 15MB
(Addresses F0 0000 – FF FFFF) can be used by ISA
expansion cards.
Item Specific Help
Configure serial port A
[Enabled]
using options:
[3F8]
[IRQ 4]
[Disabled]
[Enabled]
[2F8]
[IRQ 3]
[Enabled]
[Enabled]
[Output only]
[Auto]
[378]
[IRQ 7]
[OS Controlled]
+ / –
Change Values
Select
Enter
Sub-Menu
No configuration
User configuration
BIOS or OS chooses
configuration
Displayed when
controlled by OS
F9
Setup Defaults
F10
Save and Exit
SIMATIC Box PC 620 Manual