11 NCK Commissioning with HMI Advanced
11.3 System data
Machine data
Table 11-8
Normalization of phys. units of machine data and setting data: Machine data
Number
General ($MN_ ... )
10220
SCALING_USER_DEF_MASK
10230
SCALING_FACTORS_USER_DEF[n]
10240
SCALING_SYSTEM_IS_METRIC
10250
SCALING_VALUE_INCH
10260
CONVERT_SCALING_SYSTEM
10270
POS_TAB_SCALING_SYSTEM
10290
CC_TDA_PARAM_UNIT
10292
CC_TOA_PARAM_UNIT
11.3.3
Changing scaling machine data
11-296
MD : SCALING_USER_DEF_MASK + H14 ; (bit no. 4 and bit no. 2
MD : SCALING_FACTORS_USER_DEF[n] +
å MD : SCALING_FACTORS_USER_DEF[4] + 304.8
Index 4 specifies the "linear acceleration" (see above).
Identifier
Activation of scaling factors
Scaling factors of physical quantities
Basic system metric
Conversion factor for switch–over to inch system
Basic system switch–over active
Measuring system of position tables
Physical units of the tool data for CC
Physical units of the tool edge data for CC
The scaling of machine data having physical units is defined by the following
machine data:
S
MD 10220: SCALING_USER_DEF_MASK (activation of scaling factors)
S
MD 10230: SCALING_FACTORS_USER_DEF (scaling factors of physical
quantities)
S
MD 10240: SCALING_SYSTEM_IS_METRIC (basic system metric)
S
MD 10250: SCALING_VALUE_INCH (conversion factor for switchover to
INCH system)
S
MD 30300: IS_ROT_AX (rotary axis)
When scaling machine data are modified, all machine data affected by this mod-
ification due to their physical unit are converted with the next NCK reset.
Example: Redefining an A1 axis from linear to rotary axis.
of examplel 1 as hex value)
ft
1
12 * 25.4
s 2
+
mm
mm
1
1
s 2
s 2
Name/remarks
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
mm
s 2
+ 304.8;
Refer-
ence
T1