2 Hardware Descriptions
2.11 I/O module PP72/48
2.11.6
Technical data
2-90
Technical data of I/O module PP72/48
Safety
Degree of protection
Safety class
Approvals
Power consumption
At nominal load
Mechanical data
Dimensions WxHxD [mm]
Weight
Ambient environmental conditions
Heat dissipation
Temperature limits
Limits for relative humidity
Condensation
Atmospheric pressure
Transportation altitude
Shock stress during transportation
Free fall in transport packa-
ging
IP 00
Safety class I, in accordance with VDE 0106 P1: 1982
(IEC 536);
Protection against ingress of foreign bodies and water in
accordance with IEC 529
UL/CSA, CE
11W
194 x 325 x 35
Approx. 0.3 kg
without mounting plate
Open circuit ventilation
Operation
°C
0 ... 50
5 ... 95 %
without condensation
Not permissible
700 ... 1060 hPa
–
v1000 mm
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
Approx. 1.2 kg
with mounting plate
Storage/transport
°C
°C
–20 ... 55
/–40 ... 70
5 ... 95 %
without condensation
700 ... 1060 hPa
–1000 ... 3000 m