Indoor Unit Installation

4.1

Indoor Unit Parts

Air inlet
Air outlet
Fig. 1.
Safety Precautions
WARNING
• Securely install the indoor unit on a structure that can sustain its
weight. If the structure is too weak, the unit may fall causing person-
al injury, unit and property damage or death.
• DO NOT install the indoor unit in the bathroom or laundry room as
excessive moisture can short the unit and corrode the wiring.
CAUTION
• Install the indoor and outdoor units, cables and wires at least
1 m from televisions or radios to prevent static or image distor-
tion. Depending on the appliances, a 1 m distance may not be
sufficient.
• If the indoor unit is installed on a metal part of the building, it
must be electrically grounded.
Climate 5000 SCI – 6720887422 (2019/07)
4.2
Step 1: Select installation location
The indoor unit should be installed in a location that meets the following
requirements:
f Enough room exists for installation and maintenance.
f Enough room exists for the connecting pipe and drainpipe.
Electric control cabinet
f The ceiling is horizontal and its structure can sustain the weight of
Air filter (on some
models)
f The air inlet and outlet are not impeded.
f The airflow can fill the entire room.
Drain hose
f There is no direct radiation from heaters.
f Models with a cooling capacity of 9000 Btu to 18000 Btu only apply
Refrigerant
connecting
pipe
Fig. 2.
DO NOT install the unit in the following locations:

Indoor Unit Installation Instructions

the indoor unit.
to one room.
Maintenance roomage
200 mm or more
CAUTION
In areas with oil drilling or fracking
In coastal areas with high salt content in the air
In areas with caustic gases in the air, such as near hot springs
In areas with power fluctuations, such as factories
In enclosed spaces, such as cabinets In kitchens that use natural gas
In areas with strong electromagnetic waves in areas that store
flammable materials or gas
In rooms with high humidity, such as bathrooms or laundry rooms
Indoor Unit Installation
300 mm or more
600 mm x 600 mm
checking orifice
7