If control takes place via an IVM operator station, the interface used is allocated a
keyboard number as standard.
From programming software version 1.25 on, the three COM2, 3, 4 interfaces are
permanently allocated to keyboard addresses 11,12 and 13 in order to allow free
configuration of keyboards 1.to 10.
Interface
COM2
COM3
COM4
These keyboards are configured for the standard key layout in Programming
keyboards.
This dialogue screen is only of any significance if a sub-station is connected to the
SIMATRIX.
In the main matrix (only SIMATRIX SYS, NEO, 648):
Only one interface can be selected for sending commands to a sub-station.
Select the serial interface, which will be used to connect the sub-station to the
SIMATRIX.
In the sub-station:
Address-directed control is only possible via COM2, i.e. the commands from the
main matrix must be received via COM2.
The sub-station address is entered using the arrow keys. It is possible to control up
to 26 sub-stations.
The menu option Remote control and message receiving automatically sends
the sub-station number when dialling a camera. This allows a test of whether the
sub-station address is correct or not.
Ports on the video matrix
Keyboard
Keyboard 11
Keyboard 12
Keyboard 13
93