Prodave s7 v5.5 toolbox for windows 95/98/nt/me/2000 applications for a data link of pgs/pcs to simatic s7 via mpi interface and pc/mpi cable (82 pages)
Summary of Contents for Siemens Stratos Outstation
Page 1
October 2017 COPYRIGHT STATEMENT The information contained herein is the property of Siemens plc. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
Page 2
There are various RJ45 connectors used to connect to peripheral boards within the Stratos Outstation. Most are not Ethernet ports (See Figure 6) and should not be connected to other equipment, including PCs to avoid damage to the Stratos Outstation or user equipment.
Sopers Lane, Poole, Dorset, BH17 7ER NTRODUCTION Purpose This handbook gives details of the facilities available in the Stratos Outstation and describes the procedures for the Installation and Commissioning and provides guidance on routine maintenance and fault finding: Sections 2 to 3 cover the general operation and product features.
GNU General Public License, the GNU Lesser General Public License, the modified BSD license and the MIT license. In the event of conflicts between Siemens license conditions and the Open Source Software license conditions, the Open Source Software conditions shall prevail with respect to the Open Source Software portions of the software.
Mobility, Intelligent Traffic Systems Sopers Lane, Poole, Dorset, BH17 7ER ENERAL The Siemens Stratos Outstation provides UTMC OTU, MOVA and Stratos functions on a modular platform in a compact form factor. Product Features The main features of the Stratos Outstation are: ·...
Mobility, Intelligent Traffic Systems Sopers Lane, Poole, Dorset, BH17 7ER Product Overview The Stratos Outstation provides control and monitoring of traffic controllers and other on- street equipment. The outstation provides an Ethernet port for IP connectivity to an instation. The controller interface can be semi-integral, where the data is transferred via RS232, or freestanding, where the interface is via individual I/O relay contacts or a combination of the two.
Mobility, Intelligent Traffic Systems Sopers Lane, Poole, Dorset, BH17 7ER 2.3.1 Semi-Integral Interface to Controllers Supporting the ESP Link Figure 1 – Typical Semi-Integral Stratos Outstation Connectivity The following data is transferred between the controller and the outstation via RS232 serial cable. ·...
– see 3.3 Controller Monitor. 2.3.3 Freestanding Interface to Controller without Monitoring. Figure 3 – Typical Freestanding Stratos Outstation Connectivity The RS232 serial cable is used only for remote handset. The following data is transferred between the controller and the outstation via TR2523 compliant voltage-free relay contacts.
The integrated PSU board (section 4.6) includes a small number of I/O. A maximum of three 48-16 I/O boards (section 0) can be fitted to the Stratos Outstation. This provides a maximum general purpose I/O count for a Stratos Outstation as:...
Stratos Outstation must communicate the power loss state to an in-station. The battery backup period is set in firmware to 1 minute. After this time the Stratos Outstation will switch itself off. Typically the backup power will also support any connected 48-16 IO cards and a range of communications devices (e.g.
For more information see the User Interface Handbook 667/HU/46000/000. 3.14 Remote Reboot Remote reboot allows the Stratos Outstation to be rebooted. This function is available on the System web page. 3.15 Inventory Information Where available, inventory information is collected about the various assets within the system (software and hardware).
Smart Cards. For storage on the unit, a SIM size Smart Card is fitted in the Smart Card holder on the CPU Board. Licences are easily installed onto a Stratos Outstation either by mounting the licence Smart Card on the CPU Board or, if a card is already fitted, transferring the licence onto the fitted card using a USB Smart Card reader.
A simple stateless TCP proxy server application has been included in release 8.0.0 and later of the Stratos Outstation firmware. The proxy server will allow up to ten ingress to target port routings to a single target IP address. This feature allows specific limited “remote”...
OMPONENTS System Block Diagram The Stratos Outstation is a modular product that can be configured to provide many functions. The main components and connections of the Stratos Outstation are shown in Figure 5. General assembly drawings for the main components are shown in appendices.
The Generic Serial Peripheral Interface (GSPI) Bus is used within the system to connect serial communications and power to the main intelligent components of the system. In the Stratos Outstation the power source on the GSPI bus is the PSU board, but the communications master is the CPU board.
Page 40
The user can choose to turn these notification warnings off and vary the thresholds at which the warning notifications are generated. See the ‘User Interface Handbook for ST950 and Stratos Outstation’ 667/HU/46000/000 section 15.2.3. The following fault/notification table and system log messages are generated from the battery self tests and continued monitoring.
This screwdriver-adjustable switch is located on the I/O board(s) as shown in Figure 12 and is set up for the board address (before the Stratos Outstation is powered up) in accordance with the appropriate Works Specification. The valid address range is 1 through 15 (where A to F denote 10 to 15 respectively).
Sopers Lane, Poole, Dorset, BH17 7ER The Intelligent Detector Backplane The Stratos Outstation can be connected to intelligent detector backplane(s) for better integration with detectors. Each IDB can be used with up to four loop detectors and provides a GSPI interface which removes the need to wire discrete detector outputs into I/O board inputs and provides a mechanism for terminating the street loop wiring for 16 loops for each backplane fitted.
Page 52
When defining a system it is important to consider the number of single detectors, IDBs and Stratos outstation along with rack size to determine the build format. Table 22 below will help in the design phase to define the physical rack space required.
4.11 Racks The Stratos Outstation can also be ordered in either an 11” or 19” 3U rack and optionally an associated 2U tray where other equipment such as detectors and routers can be mounted. For information on routers and mounting refer to the IP router installation guide...
Sopers Lane, Poole, Dorset, BH17 7ER NSTALLATION OMMISSIONING This section describes in detail how to install and commission Stratos Outstation installations. For a summarised process see Appendix C. Mains voltages may still be present within the unit even if it has been isolated if the unit has been connected to other sources of mains voltages for the purpose of monitoring those voltages (e.g.
Page 56
USB WiFi Dongle (Can be used with WiFi laptop or smart phone) 667/1/45966/001 Cabinet Access If the outstation is mounted in a Siemens Traffic Controller, one or more of the following will be required to gain access to the controller cabinet. Description...
Mobility, Intelligent Traffic Systems Sopers Lane, Poole, Dorset, BH17 7ER Preparation Before attending site to Install a Stratos Outstation check that you have the following pre- requisites: · Installation tools as described above in section 5.1.3. · Ensure that the Outstation is the correct variant of the product.
667/1/33770/000 * * Some earlier swing frame assemblies mount the Gemini with the front panel horizontal. If the internal backup battery is fitted the Stratos Outstation can be mounted in any orientation apart from front panel facing down. Power Supply Connection Ensure a suitable separate protected supply (fuse or breaker) is available and suitably rated.
Stratos Outstation). Controller Serial Connection The Stratos Outstation can be connected to the TR 2523 port of a traffic controller using the correct RS232 interface cable and baud rate as shown in the tables below: Supplier...
Page 63
Tenant Pass Phrase is not specified at the time of initial connection then the equipment will be allocated to the Siemens Support team who can then make the allocation when required based on the outstation name, unique site id and destination tenant. This item has no effect after initial connection to Stratos.
When connecting to systems other than Stratos if IP communications are to be used, the correct system IP address must be programmed into the Stratos Outstation before connecting it to the network to ensure that no IP conflicts occur and that the unit is on the correct subnet.
In order to support the last gasp dial functionality the comms device must be powered from a backup supply. If using the Stratos outstation to provide the backup the comms devices power supply must be wired to the Modem Power connector pins 2 & 3 as shown in the table below.
Switch the unit on and check that the appropriate LEDs illuminate on the PSU and CPU boards. If the Stratos Outstation is equipped with an internal backup battery, ensure that it is enabled by setting the front panel ‘BATTERY’ switch to the ‘ON’ position.
Mobility, Intelligent Traffic Systems Sopers Lane, Poole, Dorset, BH17 7ER The Stratos Outstation self test functions are present to aid fault finding and are accessed through the Tester web page on the top navigation pane. Results for tests are displayed against each test with totals available at the top of the web page for ease of analysis.
30 days. First Line Replacement of the following components is considered first line maintenance. Maintenance work beyond the first line should be referred to Siemens. Part numbers and spares are listed in the Appendix. Authorised agents may replace the following: ·...
When replacing a fuse it is important to fit the correct type and rating for continued protection of the Stratos Outstation and users equipment. Before changing any fuses ensure that the unit is disconnected from the AC mains supply and that the battery is isolated using the front panel switch S1.
Page 83
The battery is shipped with the battery isolation switch open. The battery is to be recycled in an appropriate manner. Elexon Codes The Elexon Charge Codes that apply to Stratos Outstation can be found in the Siemens document 667/RE/29050/000. Security classification...
Siemens Traffic may invalidate the warranty and/or safety of this product. Part Numbers Listed below are all the currently available main parts and spares for the Stratos Outstation. Detail can be found on the Stratos Outstation Family Tree Drawing 667/DZ/52250/ETC. Main parts Description Part Number Stratos Outstation –...
Page 85
Lamp Supply Monitor Cable Assembly (3m) 667/1/47177/000 ST750ELV Lamp Supply Monitor Kit (3m) 667/1/47178/000 Stratos Outstation to Siemens Traffic Controller Serial Cable 667/1/47176/100 Stratos Outstation to Peak TLC3, C3000, Microsense Controller Serial Cable 667/1/47176/101 OTU Rack Backplane Wiring Kit (4 wires) 667/1/31612/000 Spares Description...
Wire the mains supply lead into the AC supply feed identified. Secure the mains lead to the back of the Stratos Outstation unit with a cable tie to the tie point provided. For lamp supply monitoring, identify the lamp supply point within the target system and using suitable cable, wire the lamp supply to the Stratos Outstation lamp supply connector.
Page 87
Carry out configuration of facilities and start as required (e.g. UTMC OTU, MOVA, Controller Monitor – see related documents for details) g. Check the Fault Table for faults & Notifications before leaving site 14. Complete the Stratos Outstation UTMC Commissioning data (667/CI/52250/000) leaving form...
Mobility, Intelligent Traffic Systems Sopers Lane, Poole, Dorset, BH17 7ER Appendix D Stratos Outstation Basic Unit General Assembly Security classification Unrestricted Page 88 of 92 Version Status Issued Last Editor Alan Doyle Date 05-Oct-2017 Document Name Stratos Outstation General and ICM Handbook Document No.
Mobility, Intelligent Traffic Systems Sopers Lane, Poole, Dorset, BH17 7ER Appendix E Stratos Outstation I/O & TC12 Adaptor General Assembly Security classification Unrestricted Page 89 of 92 Version Status Issued Last Editor Alan Doyle Date 05-Oct-2017 Document Name Stratos Outstation General and ICM Handbook Document No.