  • Page 1 TRIVAC NT 5 / NT 10 Rotary Vane Vacuum Pumps Operating Instructions 17200918_002_A1 140 212 140 213 140 214 140 216 140 312 140 313 140 314 140 316...
  • Page 2: Table Of Contents

    Checking the Oil Level Oil Change Cleaning the Inlet Screen Disassembly and Assembly of the Internal Demister Disassembly and Assembly of the Electric Motor Troubleshooting Wearing and Original Parts Waste Disposal EC Declaration of Conformity 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 3: Important Safety Information

    Caution destruction of the equipment. The TRIVAC NT 5/10 pumps from Oerlikon Leybold Vacuum have been designed for safe and efficient operation when used properly and in accordance with this manual. It is the responsibility of the user to carefully read and strictly observe all safety precautions described in this chapter and throughout the manual.
  • Page 4 ■ When moving the TRIVAC NT always use the allowed means. A lifting eye is provided as standard on the pump. ■ The pump when filled with oil must only be moved in its vertical position. Spilled oil involves the risk of falling. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 5 EC Declaration of Conformity) please note the information provided in the supplementary sheets. We reserve the right to modify the design and the specified data. The illustra- tions are not binding. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 6: Description

    Moreover, these pumps are not suited for pumping of hazardous gases or extremely aggressive or corro- sive media. If in doubt please consult Oerlikon Leybold Vacuum. The drive motor of the TRIVAC NT is screwed directly to the bearing piece.
  • Page 7: Principle Of Operation

    12 Diaphragm valve 13 Exhaust valve 14 Exhaust port Fig. 2 Operating principle of a TRIVAC NT 5 (other TRIVAC NT types operate in a similar way) Principle of Operation The rotor (2/6) which is eccentrically arranged in the pump housing (pump chamber) has two radially sliding vanes (2/7 and 2/9) which divide the pump chamber of the pump into several chambers.
  • Page 8 This and the combination with the large usable oil reservoir, results in long intervals between the oil exchanges, even at high intake pressures. The gas ballast valve (GB) is opened or closed by turning it (positions 0, 1, 2, 3). 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 9: Supplied Equipment

    Not all types of oil have been released for all pumps. You must only use Caution the kind of oil which has been specified for the particular pump. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 10: Technical Data

    * acc. to DIN 28 426 T1, ** acc. to DIN 28 400 ff, with 3-ph. motor Caution Only provided the lubricants recommended by us will we guarantee that the pump will attain its specified technical data. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 11: Motor Dependent Data

    Values for up-front fuses for short-circuit protection. Please take note of the information provided by the manufacturers of contactors and motor protection switches. NT 10 NT 5 mbar 10 Druck Pressure Fig. 4 Pumping speed curves of the TRIVAC NT 5 and NT 10 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 12 1~, Japan 1~, EURO 1~, DV motor 156* 156* 3~, World 1~, Japan * Capacitors in the junction box DV = Dual voltage motor (all dimensions are in mm) Fig. 5 Dimensional drawing 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 13: Ordering Information

    177 01 177 02 20 l 177 03 Use only types of oil specified by Oerlikon Leybold Vacuum. Note Alternative oils are stated upon request. The necessary connection components for connecting the exhaust filter and the condensate separator in each case are stated in the following:...
  • Page 14: Transporting And Storing

    Add some desicccant (silica gel) into the bag and seal off the bag. When having shelved the pump for more than one year, perform maintenance on the pump and an oil exchange before recommissioning the pump. We recommend to contact our service. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 15: Installation

    Before connecting the pump, the shipping seals on the connection flanges seals (6/1 and 6/2) must be removed. If residues of adhesives are present on the connecting flanges you must remove these using a suitable solvent like alco- hol, for example. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 16 Possible conse- quences can be a damaged or even burst open pump. For this reason the exhaust line must be checked from time to time to ensure that there are no obstructions. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 17: Electrical Connections

    The mains voltage must comply with the voltage stated on the name plate. When the thermal motor overload protection system has switched the Warning motor off, the motor will automatically cut in again when the temperature has dropped below the maximum permissible operating temperature. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 18: Pumps With Three-Phase Motor

    If this is not the case you must interchange two of the mains phases. Note the direction indicating arrow on the fan cowl. 3.4.2.1 Current Drawn by the Three-Phase Motors of the TRIVAC NT 5 and NT 10 Voltage ranges for Max. current consumption Min.
  • Page 19: Operation

    Possible conse- quences can be a damaged or even burst open pump. Thus the exhaust line must be checked from time to time to ensure that there are no obstructions. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 20: Operation

    Proper operation of the TRIVAC NT is ensured at ambient temperatures bet- ween 12 °C and 50 °C, with the exception of the pump models for the USA and Japan where a range of 12 °C to 40 °C applies. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 21: Shutting Down/Shelving

    This applies equally to emergency cut-out arrangements. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 22: Maintenance

    Service at Oerlikon Leybold Vacuum Contamination If you send equipment to Oerlikon Leybold Vacuum indicate whether the pump is free of substances damaging to health or whether it is contamina- ted. If it is contaminated also indicate the nature of hazard. To do so, you must use a preprinted form which we shall send to you upon request.
  • Page 23: Maintenance Schedule (Recommendation)

    ■ Replacement of all gaskets = Annual maintenance ■ Functional check. n-a = Maintenance every n years This check should be performed by the Oerlikon- * At high gas throughputs and higher temperatures within a Leybold-Vacuum-Service. pressure range >100 mbar shorter maintenance intervals apply.
  • Page 24: Checking The Oil Level

    Let the quantity of oil needed for testing flow from the oil drain opening (8/4) into a beaker with the pump switched off and while still warm from operation. Warning Note the safety information given in Chapter 5. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 25: Oil Change

    17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 26: Cleaning The Inlet Screen

    Note Adapt the cleaning intervals according to the requirements. If large quanti- ties of abrasive materials are involved you should install a dust filter in the intake line. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 27: Disassembly And Assembly Of The Internal Demister

    Place the pump on the front side of the oil box (10/1). Remove the four hex. screws (10/2) from the fan cowl (10/3). Detach the fan cowl. Unscrew the four tie rods (10/4). 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 28 Tighten the bolts for the pump’s base to 23 Nm. Especially note the position of the oil ejection hole (see arrow in Fig. 10) in Note the end plate A. The hole must always lead downward. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 29: Troubleshooting

    1) Bubble test: the warm pump with degassed oil is running without gas ballast with the intake blanked off. The exhaust line is lead into a vessel containing water. If an evenly spaced row of bubbles appears, then the pump has developed an external leak. 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 30 With a very high motor start-up capacitor. (for at least 10 minutes). temperature or a very high cur- (Voltage too low). Ensure that the supply voltage is rent uptake (> 15 A). correct (see motor nameplate). 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 31: Wearing And Original Parts

    Disassemble clean equipment, separate and dispose of the materials accor- ding to their type. When returning equipment back to us, please note the information provided in Chapter “5.1 Service at Oerlikon Leybold Vacuum”. Disposal of Waste Oil Owners of waste oil are entirely self-responsible for proper disposal of this waste.
  • Page 32: Ec Declaration Of Conformity

    17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 33 I / we hereby declare that the information supplied on this form is accurate and sufficient to judge any contamination level. Name of authorised person (block letters): ____________________________ Date _____________ Signatur of authorised person ___________________________ firm stamp 17200001_002_00 © Oerlikon Leybold Vacuum 17200918_001_A1 - 06/2008 - © Oerlikon Leybold Vacuum...
  • Page 34 Sales and Service Germany Europe Asia Oerlikon Spain P.R. China Japan Belgium Leybold Vacuum GmbH Oerlikon Oerlikon Oerlikon Oerlikon Bonner Strasse 498 Leybold Vacuum Spain, S.A. Leybold Vacuum (Tianjin) Leybold Vacuum Leybold Vacuum Nederland B.V. D-50968 Cologne C/. Huelva, 7 International Trade Co.