6 - Operation
6.0 - Option selection Dip-Switch
SELECTION
FUNCTION
1
Reserved (always keep off)
Informs the CAN control station that the thruster is in the bow (OFF)
2
Informs the CAN control station that the thruster is in the stern (ON)
3
Reserved (always keep off)
4
Reserved (always keep off)
FACTORY SETTING: 1 = OFF , 2 = OFF , 3 = OFF , 4 = OFF
6.1 - Actuator current rotary switch
The ten selectable steps (from 0 to 9) allow you to set a percentage (see table) regarding the maximum current/load allowed
for the actuator in use.
ROTARY SWITCH
POSITION
0
1
2
3
4
5
6
7
8
9
Should a setting different to the factory one be requested, carry out the following operations:
1) Turn the arrow of the rotary switch to the desired position with the board not powered.
2) When the board is powered, the percentage corresponding to the selected position will automatically be set.
If the maximum current/load is too low compared to the real operating requirements, may intervene protections against high
absorption of the actuator in closing and opening the retractable, with flashing 1 and 7 errors.
MAXIMUM CURRENT/
LOAD %
28%
36%
44%
52%
60%
68%
76%
84%
92%
100%
BTR185 INSTALLATION AND USE MANUAL - REV009A
BTR185
EN
DIP-SWITCH
ON
1
2 3 4
ON
1
2
3 4
ON
1
2
3 4
ON
1 2
3
4
ON
1 2 3
4
ON
1 2 3 4
39