  • Page 1 Operating instructions Commercial air purifier PAC 1045/1080/1200 To avoid the risk of accidents or damage to the en-GB machine, it is essential to read these instruc- tions before it is installed and used for the first time. M.-Nr. 11 855 790...
  • Page 2: Table Of Contents

    Contents Caring for the environment .................... Disposing of filters......................Warning and Safety instructions..................Appropriate use ......................... Foreseeable misuse......................Technical safety......................... Product description......................Functional description ....................... Using the machine......................10 Initial commissioning......................10 Operating the air purifier....................10 Control panel ......................... 10 Overview of operating modes ..................
  • Page 3: Caring For The Environment

    Recycling the packaging material reduces the use of raw materials in the manufacturing process and also reduces the amount of waste in landfill sites. You can return the packaging to your Miele dealer. Disposal of your old appliance Electrical and electronic appliances often contain valuable materials.
  • Page 4 Caring for the environment Disposing of old batteries In many cases, electrical and electronic appliances contain batteries which must not be disposed of with household waste after use. You are legally obliged to remove any old batteries which are not securely enclosed by the appliance and take them to a suitable collection point (e.g.
  • Page 5: Warning And Safety Instructions

    Warning and Safety instructions Please read the operating instructions before using the air purifier for the first time. They contain important information for your safety, as well as information on using and maintaining the air puri- fier. To avoid the risk of accidents or damage, it is essential to read the operating instructions carefully before using the appliance for the first time.
  • Page 6: Foreseeable Misuse

     Do not make any alterations to the air purifier, unless authorised to do so by Miele.  To ensure the correct performance of the air purifier and to prevent the risk of faults, it is important to carry out maintenance on a regular basis.
  • Page 7 Miele cannot accept liability.  Faulty components may only be replaced by genuine Miele spare parts. Miele can only guarantee the safety standards of the appliance when Miele spare parts are used.  In the event of a fault and for cleaning and maintenance purposes, the air purifier must be disconnected from the power supply.
  • Page 8: Product Description

    Product description Lockable access flap Protects the air purifier controls against unauthorised access. Air intake vents On the left and right sides, rear and bottom of the plinth Lid with air outlet vents 4 adjustable feet 4 adjustable feet are supplied for optional stabilisation Control panel with display Operation with timed and manual control.
  • Page 9: Functional Description

    Product description Functional description The Miele air purifier draws in atmospheric air at the bottom via the air intake vents in the plinth (). The pre-filters () filter coarse dust out of the air. The air is conveyed upwards by the fan inside the air purifier and is pushed through the main filter and the active charcoal fil- ter ().
  • Page 10: Using The Machine

    Using the machine Initial commissioning Before carrying out initial commissioning, it is important to check that the air purifier is installed in accordance with appropriate use guidelines. After installation, allow the air purifier to adjust to room temperature. Check the air purifier, the plug and the mains connection cable for damage.
  • Page 11: Overview Of Operating Modes

    Fan run-on The fan keeps running after Miele ThermoControl in order to cool the filter. Intensive circ. The fan runs at a higher speed for a short period in order to quickly circulate the air within the room.
  • Page 12: Button Functions

    Using the machine Button functions The following button functions apply during operation. The logic func- tion varies depending on the operating status, as detailed below: Button Type of actu- Button Logic function ation function  Press, Switch on, Switch between operating statuses (see “Changing the op- release next or erating status”).
  • Page 13: Setting The Operating Mode/Calling Up The Settings Menu

    Using the machine Setting the oper- You can change the set operating mode in any operating status by ating mode/call- holding down the  and  buttons at the same time for at least ing up the Set- 3 seconds. You will then be prompted to enter the following access tings menu code: User code...
  • Page 14: Changing The Operating Status

    Press the  button repeatedly until you reach the desired operating  status. Tip: If you wish to clean the filter manually via Miele ThermoControl, press the  button repeatedly until you reach the ThermoControl act- operating status. Relevant pathogens will then be deactivated in the filter by Miele ThermoControl.
  • Page 15: Settings

    6:00 am with 5 minutes of initial flow time, the air purifier will start at 5:55 am. After the switch-off time, Miele ThermoControl is started with a run- ning time of 20 minutes. This is followed by a 10-minute fan run-on phase.
  • Page 16: Settings Menu For "Co2 Mode

    Using the machine - If you do not want to set a separate switch-on time and switch-off time for each day, you can set the times for the whole week quickly Mon–Fri/Sat+Sun . If the switch-on time and switch-off time are set to 00:00, the appliance will not switch on on the selected day.
  • Page 17: Settings Menu For "Co2+Time Mode

    6:00 am with 5 minutes of initial flow time, the air purifier will start at 5:55 am. After the switch-off time, Miele ThermoControl is started with a run- ning time of 20 minutes. This is followed by a 10-minute fan run-on phase.
  • Page 18: Settings Menu For "Language/Time/Date/Service

    Settings Date Time Date 10.12.2020 Service Please set Settings Date Service Change filter * For the Miele Customer Service Department only Settings menu for Settings Change filter Reset filter time Service Reset filter time “Change filter/ Change filter Back Back Factory defaults...
  • Page 19: Installation

    Installation Transport and installation Only personnel who have received instruction from the supervisor may transport and install the air purifier.  Risk of tipping during unsecured transport. There is a risk that the air purifier may tip over in the event of unse- cured transport with incorrect transport equipment or lifting equip- ment.
  • Page 20: Mounting The Adjustable Feet

    Installation Mounting the adjustable feet The air purifier is supplied with 4 adjustable feet which can be mounted on the bottom of the plinth in order to stabilise the appli- ance. At least 2 people are required to fit the adjustable feet. To fit the adjustable feet to the bottom of the air purifier, tilt the air ...
  • Page 21: Wall Bracket (Optional)

    Installation Screw the adjustable feet out far enough that the air purifier stands  entirely on the feet when in its upright position (castors not in con- tact with the floor). Adjust the adjustable feet until the air purifier is level. Use a spirit ...
  • Page 22: Electrical Connection

    If the mains connection cable is damaged, it must only be replaced with a specific mains connection cable of the same type (available from the Miele Customer Service Department). For safety reasons, such replacement may only be carried out by a qualified specialist or the Miele Customer Service Department.
  • Page 23: Cleaning And Care

    If the air exchange rate drops below 4 air changes, this is sig- nalled by the red LED lighting up and a warning message appearing. Miele recommends checking the saturation of the filter regularly by Manual setting the fan setting to 100 % for at least 20 seconds in...
  • Page 24 Cleaning and care Fan settings for PAC 1080 Room size Flow rate for 6 air Fan setting for 6 air Fan setting (%) for 6 air changes* changes (new filter) changes (filter saturated – red LED lights up at 100 %) 25 m² 413 m³/h 45 % 60 %...
  • Page 25: Removing Fluff And Dust From The Pre-Filter

    Contaminated filters must always be replaced with new ones. When replacing filters, only use accessory parts approved by Miele. If other parts are used, warranty, performance and/or product liabil- ity claims will be invalidated.
  • Page 26 Cleaning and care Remove the plug from the socket and ensure that the air purifier is  de-energised. If the appliance was in operation before it was unplugged, wait ap-  prox. 10 minutes to allow it to cool down fully. The housing may still be warm immediately after operation.
  • Page 27: Replacing The Main Filter And Active Charcoal Filter

    Cleaning and care Replacing the Miele recommends having the main filter and the active charcoal fil- main filter and ter replaced by the Miele Customer Service Department. active charcoal filter PAC 1045/1080 PAC 1200 Exhaust filter gauze Active charcoal filter Main filter (particulate pre-filter ISO ePM2.5 60 % (F7) and high-...
  • Page 28 (F7) and high-performance filter HEPA H14) must be replaced roughly every 2 years in order to optimise operation of the air puri- fier. Miele recommends having the main filter replaced by the Miele Customer Service Department in order to guarantee that the air puri- fier is properly sealed afterwards.
  • Page 29 Cleaning and care Before switching on the air purifier, check that the lid is screwed tight. Resetting the filter After changing the main filter, the filter life must be reset manually in life the settings menu. Change filter Settings Select the option in the menu.
  • Page 30: Problem Solving Guide

    Repair work to electrical appliances should only be carried out by an authorised techni- cian. Contact in case of malfunction In the event of any faults which you cannot remedy yourself, please contact your Miele Dealer or Miele Service. Contact information for Miele Service can be found at the end of this document.
  • Page 31 You can keep using the air purifier until the battery is re-  been set (e.g. time, timer placed by the Miele Customer Service Department. Re- values). set the lost data via the Settings menu. The yellow LED flashes The CO2 limit has been reached or exceeded.
  • Page 32 The red LED flashes and The main filter no longer works and must be replaced. F2081 warning the message Contact the Miele Customer Service Department or re-  is shown on the display. place the main filter (see “Cleaning and care – Filter re- placement”).
  • Page 33: Technical Data

    Technical data Model PAC 1045 PAC 1080 PAC 1200 Supply voltage 230 V 230 V 230 V Fuse rating (on site) 16 A ≥ 10 A 16 A ≥ 10 A 16 A ≥ 10 A Motor 780 W 780 W 1300 W Heating 1300 W 1300 W...
  • Page 34 United Kingdom Malaysia Miele Sdn Bhd Miele Co. Ltd., Fairacres, Marcham Road Suite 12-2, Level 12 Abingdon, Oxon, OX14 1TW Menara Sapura Kencana Petroleum Professional Sales, Tel: 0845 365 6608 Solaris Dutamas No. 1, Jalan Dutamas 1 E-mail: professional@miele.co.uk 50480 Kuala Lumpur, Malaysia Internet: www.miele.co.uk/professional...