Function List
Code
b088
Restart mode after FRS
b089
Automatic carrier frequency reduction
b090
Dynamic braking usage ratio
b091
Stop mode selection
b092
Cooling fan control
b093
Accumulated time clear of the cooling fan
b094
Initialization target data setting
b095
Dynamic braking control (BRD) selection
b096
BRD activation level
b097
BRD register
b100
Free-setting V / F freq. (1)
b101
Free-setting V / F volt. (1)
b102
Free-setting V / F freq. (2)
b103
Free-setting V / F volt. (2)
b104
Free-setting V / F freq. (3)
b105
Free-setting V / F volt. (3)
b106
Free-setting V / F freq. (4)
b107
Free-setting V / F volt. (4)
b108
Free-setting V / F freq. (5)
b109
Free-setting V / F volt. (5)
b110
Free-setting V / F freq. (6)
b111
Free-setting V / F volt. (6)
b112
Free-setting V / F freq. (7)
b113
Free-setting V / F volt. (7)
b120
Brake control enable
b121
Brake Wait Time for Release
b122
Brake Wait Time for Acceleration
b123
Brake Wait Time for Stopping
b124
Brake Wait Time for Confirmation
b125
Brake release freq. setting
b126
Brake release current setting
b127
Braking frequency
b130
Over-voltage LADSTOP enable
b131
Over-voltage LADSTOP level
b132
DC bus AVR constant setting
b133
DC bus AVR for decel. Proportional-gain
b134
DC bus AVR for decel. Integral-time
b145
GS input performance selection
b150
Panel Display selection
b160
1st parameter of Double Monitor
b161
2nd parameter of Double Monitor
b163
Data change mode selection of d001 and d007
b164
Automatic return to the initial display
b165
Action selection in case of external operator disconnection
b166
Data Read / Write selection
b171
Inverter mode selection
b180
Initialization trigger
b190
Password A setting
b191
Password A for authentication
b192
Password B setting
b193
Password B for authentication
16
Function Name
00 (starting with 0 Hz) /
01 (starting with matching frequency) /
02 (starting with active matching frequency)
00 (disabled) /
01 (enabled [output current controlled]) /
02 (enabled [fin temperature controlled])
0.0 to 100.0 [%]
00 (deceleration until stop) /
01 (free-run stop)
00 (fan always ON) /
01 (ON fan only during inverter operation
02 (fin temperature controlled)
00 (count) / 01 (clear)
00 (All parameters) /
01 (All parameters except in/output terminals and communication) /
02 (Uxxx) / 03 (expect Uxxx)
00 (disabled) /
01 (enabled [disabled while the inverter is stopped]) /
02 (enabled [enabled also while the inverter is stopped])
330 to 380 / 660 to 760 [V]
Set range : minimum connectable register
Rbmin to 600.0 [Ω]
0. to b102 [Hz]
0.0 to 800.0 [V]
0. to b104 [Hz]
0.0 to 800.0 [V]
0. to b106 [Hz]
0.0 to 800.0 [V]
0. to b108 [Hz]
0.0 to 800.0 [V]
0. to b110 [Hz]
0.0 to 800.0 [V]
0. to b112 [Hz]
0.0 to 800.0 [V]
0. to 400 ( to 1000) [Hz]
0.0 to 800.0 [V]
00 (disabled) / 01 (enabled)
0.00 to 5.00 [s]
0.00 to 5.00 [s]
0.00 to 5.00 [s]
0.00 to 5.00 [s]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
Set range: 0 to 200% of inverter rated current [A]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
00 (disabled) / 01 (enabled) / 02 (enabled with acceleration)
330 to 395 / 660 to 790 [V]
0.10 to 30.00 (s)
0.00 to 5.00
0.0 to 150.0 [s]
00 (non Trip) / 01 (Trip)
d001 to d060
d001 to d030
d001 to d030
00 (disabled) / 01 (enabled)
00 (disabled) / 01 (enabled)
00 (tripping) / 01 (tripping after decelerating and stopping the motor) /
02 (ignoring errors) / 03 (stopping the motor after free-running) /
04 (decelerating and stopping the motor)
00 (read / write enable) / 01 (both read, write disable)
00 (disabled) / 01 (IM enabled)
00 (disabled) / 01 (enabled)
0 (disabled) / 0001 to FFFF (enabled)
0000 to FFFF
0 (disabled) / 0001 to FFFF (enabled)
0000 to FFFF
Setting Range
[including 5 minutes after power-on and power-off]
) /
[ ○ = Allowed × = Not parmitted]
Setting During
Change During
Default
Operation
Operation
Setting
(allowed or not)
(allowed or not)
×
00
○
×
×
01
×
0.0
○
×
00
○
×
01
○
×
×
00
×
×
00
×
01
○
×
360 / 720
○
Min.
×
○
resistance
×
×
0.
×
×
0.0
×
×
0.
×
×
0.0
×
×
0.
×
×
0.0
×
×
0.
×
×
0.0
×
×
0.
×
×
0.0
×
×
0.
×
×
0.0
×
×
0.
×
×
0.0
×
00
○
×
0.00
○
×
0.00
○
×
0.00
○
×
0.00
○
×
0.00
○
Rated current
×
○
of inverter
×
0.00
○
×
00
○
×
380 / 760
○
×
1.00
○
0.20
○
○
1.0
○
○
×
00
○
001
○
○
001
○
○
002
○
○
00
○
○
00
○
○
02
○
○
×
00
○
×
×
00
×
×
00
×
×
0000
×
×
0000
×
×
0000
×
×
0000