Summary of Contents for IBM Power Systems 9043-MRX

  • Page 1 Power Systems Adapter placement for the 9043-MRX...
  • Page 2 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 11, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
  • Page 3: Table Of Contents

    Adapter placement rules and slot priorities for the 9043-MRX ..............1 Adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I/O expansion drawer....5 Related procedures for adapter placement....................9 Finding the current system configuration in IBM i.................9 Notices........................11 Accessibility features for IBM Power servers................... 12 Privacy policy considerations ........................
  • Page 5: Safety Notices

    Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
  • Page 6 • When possible, use one hand only to connect or disconnect signal cables. • Never turn on any equipment when there is evidence of fire, water, or structural damage. • Do not attempt to switch on power to the machine until all possible unsafe conditions are corrected. •...
  • Page 7 – For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls the power to the system unit(s), or disconnect the customer’s DC power source, when directed to disconnect power during servicing. • Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet.
  • Page 8 – Ensure that there are little-to-no empty U-levels between devices installed in the rack cabinet below the 32U (compliance ID RACK-001 or 22U (compliance ID RR001) level, unless the received configuration specifically allowed it. • If the rack cabinet you are relocating is part of a suite of rack cabinets, detach the rack cabinet from the suite.
  • Page 9 • Before extending the rack to the installation position, read the installation instructions. • Do not put any load on the slide-rail mounted equipment mounted in the installation position. • Do not leave the slide-rail mounted equipment in the installation position. (L002) (L003) Safety notices ix...
  • Page 10 DANGER: Multiple power cords. The product might be equipped with multiple AC power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) (L007) CAUTION: A hot surface nearby. (L007) (L008) CAUTION: Hazardous moving parts nearby.
  • Page 11 CAUTION: Enclosure Integrity. • Access covers are intended only for occasional removal. • Follow documented procedures when opening during live or temporary service. • When service is complete, promptly reinstall all covers, lids, and/or doors for correct operation. (L031) All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products.
  • Page 12 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 13 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 14 xiv Power Systems: Adapter placement for the 9043-MRX...
  • Page 15: Adapter Placement

    Enlarged capacity 2 processors 3 processors 4 processors assign order 1 memory access (DMA) window P0-C0 eBMC P0-C1 2 PCIe4 x8 (Base Ethernet adapter use) P0-C2 PCIe4 x16 or PCIe5 P0-C3 PCIe4 x16 or PCIe5 © Copyright IBM Corp. 2022...
  • Page 16 Table 2. Slot locations and descriptions for the 9043-MRX system (continued) Location code Description SCM / PHB Slot capabilities Slot availability OpenCAPI Cable adapter Dynamic direct Enlarged capacity 2 processors 3 processors 4 processors assign order 1 memory access (DMA) window P0-C4 PCIe4 x16 or PCIe5 P0-C5...
  • Page 17 9105-41B, 9105-42A, 9786-42H, 9080-HEX, 9782-80H, 9781-50H, or 9786-22H system and EMX0 PCIe3 expansion drawers system and EMX0 PCIe3 expansion drawers (http://www.ibm.com/support/ knowledgecenter/POWER10/p10hcd/p10hcd_pcibyfeature.htm). The 9043-MRX systems can have two, three, or four system processor modules. Note: In the following table, the slot priority numbers 1 - 11 correspond to slot locations P0-C1 through P0-C11.
  • Page 18 Table 3. Adapter slot priorities and maximum adapters supported in the 9043-MRX (continued) Feature code Description Slot priority Maximum number of adapters supported 2 processors 3 processors 4 processors EJ14 PCIe3 12 GB Cache 11, 8, 10, 7, 9, 6 11, 8, 5, 3, 10, 7, 4, 2, 9 11, 8, 5, 3, 10, 7, 4, 2, 9 6/9/9...
  • Page 19: Adapter Placement Rules And Slot Priorities For The Emx0 Pcie Gen3 I/O Expansion Drawer

    Adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I/O expansion drawer Find information about the placement rules and slot priorities for the adapters that are supported for the EMX0 PCIe Gen3 I/O expansion drawer (EMX0 PCIe3 expansion drawer). Slot descriptions for the EMX0 PCIe3 expansion drawer The number of PCIe slots that are provided in the EMX0 PCIe3 expansion drawer depends on the I/O module configuration of the EMX0 PCIe3 expansion drawer.
  • Page 20 Table 4. Slot locations and descriptions for the EMX0 PCIe3 expansion drawer Slot capabilities SR-IOV Dynamic direct I/O adapter memory access enlarged capacity Location code Description (DMA) window enablement order P1-C1 PCIe3 x16 P1-C2 PCIe3 x8 P1-C3 PCIe3 x8 P1-C4 PCIe3 x16 P1-C5 PCIe3 x8...
  • Page 21 EMX0 PCIe3 expansion drawer code Slot priorities Maximum number of adapters supported ® Linux IBM i 5899 PCIe2 4-port 1 GbE adapter (FC P1-C2, P2-C2, P1- 5260 and 5899; CCIN 576F); C3, P2-C3, P1-C5, Adapter part number: 74Y4064 P2-C5, P1-C6, P2-...
  • Page 22 EMX0 PCIe3 expansion drawer code Slot priorities Maximum number of adapters supported ® Linux IBM i EJ0L PCIe3 12 GB Cache RAID SAS P1-C1, P2-C1, P1- quad-port 6 Gb adapter (FC C4, P2-C4, P1-C3, EJ0L; CCIN 57CE); Adapter part P2-C3, P1-C6, P2-C6...
  • Page 23: Related Procedures For Adapter Placement

    Find procedures that are related to adapter placement rules and slot priorities. Finding the current system configuration in IBM i You can use the System Service Tools in the IBM i operating system to find the current system configuration. Before you begin Before you begin, you must know the location codes of the PCI adapter slots in the system with which you are working.
  • Page 24 About this task To find the current system configuration, start an IBM i session and sign on. If you have more than one system, start a session on the system that is being upgraded and for which you have service tools authority.
  • Page 25: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 26: Accessibility Features For Ibm Power Servers

    This product uses standard navigation keys. Interface information The IBM Power servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 27: Privacy Policy Considerations

    Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 28 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 29 IBM Deutschland GmbH Technical Relations Europe, Abteilung M456 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A. Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase.
  • Page 30 Taiwan Notice CNS 13438: CNS 15936: IBM Taiwan Contact Information: United States Federal Communications Commission (FCC) Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 31: Class B Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 32 Zustimmung von IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung von IBM gesteckt/eingebaut werden. Deutschland: Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von Geräten Dieses Produkt entspricht dem “Gesetz über die elektromagnetische Verträglichkeit von Geräten (EMVG)“. Dies ist die Umsetzung der EU-Richtlinie 2014/30/EU in der Bundesrepublik Deutschland.
  • Page 33 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 34: Terms And Conditions

    IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed.
  • Page 36 IBM®...