Installing the IBM Power S1014
(9105-41B)
IBM
GI11-0002-00

Advertisement

Table of Contents
loading

Summary of Contents for IBM Power S1014

  • Page 1 Power Systems Installing the IBM Power S1014 (9105-41B) GI11-0002-00...
  • Page 2 “Notices” on page 13, the IBM Systems Safety Notices manuals, G229-1110 and G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. This edition applies to IBM Power Systems servers that contain the POWER10 processor and to all associated models. ©...
  • Page 3: Table Of Contents

    Contents Safety notices......................v Installing the IBM Power S1014 (9105-41B)............1 Installing a stand-alone server........................1 Prerequisite for installing the stand-alone server................. 1 Moving the server to the installation site....................1 Completing inventory for your stand-alone server................1 Cabling the server and setting up a console..................2 Completing the server setup........................
  • Page 5: Safety Notices

    Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product. Do not open or service any power supply assembly.
  • Page 6 • Each rack cabinet might have more than one power cord. – For AC powered racks, be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing. vi Power Systems: Installing the IBM Power S1014 (9105-41B)
  • Page 7 – For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls the power to the system unit(s), or disconnect the customer’s DC power source, when directed to disconnect power during servicing. • Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet.
  • Page 8 In addition, do not lean on rack-mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). Stability hazard: • The rack may tip over causing serious personal injury. viii Power Systems: Installing the IBM Power S1014 (9105-41B)
  • Page 9 • Before extending the rack to the installation position, read the installation instructions. • Do not put any load on the slide-rail mounted equipment mounted in the installation position. • Do not leave the slide-rail mounted equipment in the installation position. (L002) (L003) Safety notices ix...
  • Page 10 CAUTION: Hazardous moving parts nearby. (L008) (L018) CAUTION: High levels of acoustical noise are (or could be under certain circumstances) present. Use approved hearing protection and/ or provide mitigation or limit exposure. (L018) (L031) x Power Systems: Installing the IBM Power S1014 (9105-41B)
  • Page 11 CAUTION: Enclosure Integrity. • Access covers are intended only for occasional removal. • Follow documented procedures when opening during live or temporary service. • When service is complete, promptly reinstall all covers, lids, and/or doors for correct operation. (L031) All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products.
  • Page 12 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 13 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 14 Power Systems: Installing the IBM Power S1014 (9105-41B)
  • Page 15: Installing The Ibm Power S1014 (9105-41B)

    About this task You might need to read the following documents before you begin to install the server: • The latest version of this document is maintained online. See Installing the Power S1014 (9105-41B) (http://www.ibm.com/support/knowledgecenter/POWER10/p10jag/p10jag_roadmap.htm). • To plan your server installation, see Planning for the system (http://www.ibm.com/support/ knowledgecenter/POWER10/p10jag/p10jag_kickoff.htm.
  • Page 16: Cabling The Server And Setting Up A Console

    If you have incorrect, missing, or damaged parts, consult any of the following resources: • Your IBM reseller. • IBM Rochester manufacturing automated information line at 1-800-300-8751 (United States only). • The Directory of worldwide contacts website http://www.ibm.com/planetwide. Select your location to view the service and support contact information.
  • Page 17 This cable (part number 46K5108) is used to convert the ASCII terminal 9-pin Dshell connector to an RJ45 serial port connector on the system. For information about the locations of the connectors on the system, see Part locations and location codes (http://www.ibm.com/support/knowledgecenter/ POWER10/p10ecs/p10ecs_locations.htm).
  • Page 18 8. Press Enter until the server information appears. You have completed the setup for an ASCII terminal, and have started the ASMI. 9. Continue with “Completing the server setup without using an HMC” on page 11. 4 Power Systems: Installing the IBM Power S1014 (9105-41B)
  • Page 19 2. Connect the monitor cable to the graphics card. 3. Connect a keyboard and mouse to the blue USB 3.0 ports. 4. Power on the console. 5. Continue with “Cabling the server and connecting expansion units” on page 9. Installing the IBM Power S1014 (9105-41B) 5...
  • Page 20 Cabling the server and accessing Operations Console You can use Operations Console to manage a server that is running the IBM i operating system even if you do not have logical partitions. Before you begin You can access the Operations Console via a LAN connection to IBM i by using IBM i Access Client Solutions (http://www-01.ibm.com/support/docview.wss?uid=isg3T1026805).
  • Page 21 This might indicate that the system is not preinstalled with IBM i and you must set the console type to LAN. 6. Perform this step if the system is not preinstalled with IBM i. For setting the console type to LAN, complete the following steps: a.
  • Page 22 Use the 11, until it returns A6C3500C. This indicates that settings have been saved successfully. If not, repeat function 11 until it returns A6C3500C Note: 65+21+11 functions are no longer needed unless directed by IBM support. The functions to set an adapter location are now performed automatically by the Licensed Internal Code.
  • Page 23: Completing The Server Setup

    1. Align the door with the system chassis so that it is open 90 degrees. 2. Align the hinges on the door with the posts on the chassis. 3. Using your finger, push each hinge onto each pin, one at a time. Installing the IBM Power S1014 (9105-41B) 9...
  • Page 24 Compare your installed firmware level with available firmware levels. For more information, see the Fix Central website (http://www.ibm.com/support/fixcentral). b. If necessary, update your managed system firmware levels. In the navigation area, select Updates. 10 Power Systems: Installing the IBM Power S1014 (9105-41B)
  • Page 25 • Install the VIOS operating system. For instructions, see Installing VIOS (https://www.ibm.com/ support/knowledgecenter/POWER10/p10hb1/p10hb1_vios_install.htm). • Install the IBM i operating system. For instructions, see Installing the IBM i operating system (http:// www.ibm.com/support/knowledgecenter/POWER10/p10hdx/p10hdx_ibmi.htm). Completing the server setup without using an HMC If you do not have an Hardware Management Console (HMC), use this procedure to complete the server setup.
  • Page 26 • Install the VIOS operating system. For instructions, see Installing VIOS (https://www.ibm.com/ support/knowledgecenter/POWER10/p10hb1/p10hb1_vios_install.htm). • Install the IBM i operating system. For instructions, see Installing the IBM i operating system (http:// www.ibm.com/support/knowledgecenter/POWER10/p10hdx/p10hdx_ibmi.htm). 12 Power Systems: Installing the IBM Power S1014 (9105-41B)
  • Page 27: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 28: Accessibility Features For Ibm Power Servers

    This product uses standard navigation keys. Interface information The IBM Power servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 29: Privacy Policy Considerations

    Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 30: Class A Notices

    Class A Notices The following Class A statements apply to the IBM servers that contain the Power10 processor and its features unless designated as electromagnetic compatibility (EMC) Class B in the feature information. When attaching a monitor to the equipment, you must use the designated monitor cable and any interference suppression devices supplied with the monitor.
  • Page 31 Tel: 914-499-1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Relations Europe, Abteilung M456 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A.
  • Page 32 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 18 Power Systems: Installing the IBM Power S1014 (9105-41B)
  • Page 33: Class B Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 34 Zustimmung von IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung von IBM gesteckt/eingebaut werden. Deutschland: Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von Geräten Dieses Produkt entspricht dem “Gesetz über die elektromagnetische Verträglichkeit von Geräten (EMVG)“. Dies ist die Umsetzung der EU-Richtlinie 2014/30/EU in der Bundesrepublik Deutschland.
  • Page 35 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 36: Terms And Conditions

    IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed.
  • Page 38 IBM® Part Number: 03KG354 GI11-0002-00...